Copyright
©2023 Hanwha Vision Co., Ltd. All rights reserved.
Trademark
Each of trademarks herein is registered. The name of this product and other trademarks mentioned in this manual are the registered trademark of their
respective company.
Restriction
Copyright of this document is reserved. Under no circumstances, this document shall be reproduced, distributed or changed, partially or wholly, without
formal authorization.
Disclaimer
Hanwha Vision makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be
provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility. Hanwha Vision reserves the right
to change the contents of this document without prior notice.
※Appearance, specication, etc. of the product is subject to change for performance improvements without prior notice.
The latest update is available on the ocial Hanwha Vision website. (www.HanwhaVision.com)
※The ID for the initial login is“admin,”and a password should be set.
Please change your password every three months to protect your personal data and prevent identity theft.
Please note that users are responsible for the security and other issues caused by insucient password management.
IP Audio System
User Manual

English _3
!OVERVIEW
overview
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT
TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECT THROUGH THE
VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT.
Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases, shall be placed on the apparatus.
To prevent injury, this apparatus must be securely attached to the Wall/ceiling in accordance
with the installation instructions.
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude to constitute a risk of
electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to
the presence of important operating and maintenance (servicing) instructions in
the literature accompanying the product.
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
ATTENTION
IL Y A RISQUE D’EXPLOSION SI LA BATTERIE EST REMPLACÉE PAR UNE BATTERIE DE
TYPE INCORRECT.
METTRE AU REBUT LES BATTERIES USAGÉES CONFORMÉMENT AUX INSTRUCTIONS.
These servicing instructions are for use by qualified service personnel only.
To reduce the risk of electric shock do not perform any servicing other than that contained in
the operating instructions unless you are qualified to do so.
The ITE is to be connected only to (PoE/PoE+) networks without routing to the outside
plant.
The wired LAN hub providing power over the Ethernet (PoE/PoE+) in accordance with
IEEE 802.3af/at shall be a UL Listed device with the output evaluated as a Limited Power
Source as defined in UL60950-1 or PS2 as defined in UL62368-1.
Unit is intended for installation in a Network Environment 0 as defined in IEC TR 62102.
As such, associated Ethernet wiring shall be limited to inside the building.

overview
4_ overview
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean the contaminated area on the product surface with a soft, dry cloth or a damp cloth.
(Do not use a detergent or cosmetic products that contain alcohol, solvents or surfactants or oil constituents
as they may deform or cause damage to the product.)
7. Do not block any ventilation openings, Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/ accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer,
or sold with the apparatus. When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.
13. To prevent injury, this apparatus must be securely attached to the Wall/ceiling in
accordance with the installation instructions.
14. Unplug this apparatus during lighting storms or when unused for long periods of time.
15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged
in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into
the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been
dropped.
16. This product is intended to be supplied by a Listed Power Supply Unit marked “Class 2” or “LPS” or “PS2”
and rated from PoE(802.3af) : 44V-57V , max 300mA / PoE+(802.3at) : 50V-57V , max 510mA.
17. This product is intended to be supplied by isolation power.
18. If you use excessive force when installing the product, the product may be damaged and malfunction.
If you forcibly install the product using non-compliant tools, the product may be damaged.
19. Do not install the product in a place where chemical substances or oil mist exists or may be generated. As
edible oils such as soybean oil may damage or warp the product, do not install the product in the kitchen or
near the kitchen table.
This may cause damage to the product.
20. When installing the product, be careful not to allow the surface of the product to be stained with chemical
substance.
Some chemical solvents such as cleaner or adhesives may cause serious damage to the product’s surface.
21. If you install/disassemble the product in a manner that has not been recommended, the production functions/
performance may not be guaranteed.
22. Do not install on a surface where it is exposed to direct sunlight, near heating equipment or heavy cold area.
23. Do not place this apparatus near conductive material.
24. Do not attempt to service this apparatus yourself.
25. Do not place a glass of water on the product.
26. Do not install near any magnetic sources.
27. Do not place heavy items on the product.
28. Please wear protective gloves when installing/removing the product.
The high temperature of the product surface may cause a burn.
29. This device has been verified using STP cable. The use of appropriate GND grounding and STP cable
is recommended to effectively protect your product and property from transient voltage, thunderstroke,
communication interruption.
30. In particular installation environments, there might be interference in radio communications.
When interference of electromagnetic waves occurs between the product and radio communication device, it
is recommended to keep a certain distance between the two or change the direction of the receiving antenna..
31. An apparatus with CLASS construction shall be connected to a MAINS socket outlet with a protective
earthing connection.
32. Batteries(battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or
the like. The battery cannot be replaced.
33. Disconnect the main plug from the apparatus, if it’s defected. And please call a repair man in your location.
34. Select an installation site that can hold at least 5 times the product’s weight.
35. Stuck-in or peeled-off cables can cause damage to the product or a fire.
36. For safety purposes, keep anyone else away from the installation site.
And put aside personal belongings from the site, just in case.
37. We do not guarantee the quality of third-party products (e.g. accessories) that you separately purchase.
38. When a PoE+ power supply is being used, high volume output may affect the system stability.

English _5
!OVERVIEW
Table of Contents
OVERVIEW
3
4Important Safety Instructions
6Names and Functions of the IP Audio
Module (SPA-D1000)
6Names and functions of the IP speakers
(ceiling-mount type) (SPA-C100B/
SPA-C100W)
7Names and functions of the IP speakers
(ceiling-mount type, flame retardant
structure / Plenum rate) (SPA-C110B/
SPA-C110W)
8Names and functions of the IP speakers
(wall-mount type) (SPA-W100B/
SPA-W100W)
9Names and functions of the IP speakers
(HORN type) (SPA
-
H100B/SPA
-
H100W)
10 Names and functions of the IP speakers
(Pendant type) (SPA-P100B/SPA-P100W)
11 Broadcast System Configuration Diagram
12 Connecting To Power And A Network
STARTING
13
13 Connecting to a PC
13 Access Product
16 Logging In
ENVIRONMENT SETTINGS
17
17 System Management
19 Network Settings
20 Time Settings
21 Device operation setting
USE IN THE CONTROLLER MODE
22
22 Home Screen Configuration
22 Operation Mode
27 System Settings
37 Maintenance
USING SPEAKER MODE
38
38 Home Screen Configuration
38 Operation Settings
48 Maintenance

overview
6_ overview
NAMES AND FUNCTIONS OF THE IP AUDIO MODULE (SPA-D1000)
Side
STAT RESET
PoE+
ALARM
GND
IN OUT
LINE
OUT
+ +
— —
G
SPEAKER
a b c d
STAT RESET
PoE+
ALARM
GND
IN OUT
LINE
OUT
+ +
— —
G
SPEAKER
f
gh
e
Name Function Description
a
STATUS When the initialization is in progress, the STATUS lamp blinks fast. When the initialization is
completed, it blinks slowly in an interval of 1 second.
b
ALARM ALARM IN: An alarm input terminal.
ALARM OUT: An alarm output terminal. GND: It is a ground terminal.
c
RESET
A button that returns the product settings to the factory default values. Press the button for
approximately 12 seconds to initialize and reboot the product.
J
Do not disconnect the power until product resetting is complete. Doing so may cause malfunctions.
It will take up to 10 minutes to reboot the product after initializing it.
d
Network Terminal A terminal that connects a switching hub supporting PoE or PoE+ and a network cable for power
and network connection.
e
micro SD card slot A slot for a micro SD card.
f
SPEAKER A terminal connected to a speaker.
g
LINE OUT An output terminal for external devices, such as an amplifier.
h
Grounding port
Used for earth-grounding.
Grounding serves to protect the product from lightning strikes.
Before connection, be sure to turn off the power of the device.
M
`The IP audio module can be used as an IP speaker when connected to an analog speaker with a permissible input of 10W
or higher and an impedance of 8 ohms.
NAMES AND FUNCTIONS OF THE IP SPEAKERS (CEILING-MOUNT TYPE)
(SPA-C100B/SPA-C100W)
PoE+
STAT
RESET
ALARM
GND IN
OUT
b
a
c
d
e
Name Function Description
a
Detachable grille Prevents dust intrusion.
b
Speaker unit Generates speaker vibration.
c
Audio module Equipped with an audio module.
d
Safety cable hook Secures the speaker during installation to prevent it from falling.
e
Bracket Secures the speaker to the ceiling board.

English _7
!OVERVIEW
NAMES AND FUNCTIONS OF THE IP SPEAKERS (CEILING-MOUNT
TYPE, FLAME RETARDANT STRUCTURE / PLENUM RATE) (SPA-C110B/
SPA-C110W)
b
a
g
h
i
d
f
e
j
c
Name Function Description
a
Detachable grille Prevents dust intrusion.
b
Speaker unit Generates speaker vibration.
c
Grounding port
Used for earth-grounding.
Grounding serves to protect the product from lightning strikes.
Before connection, be sure to turn off the power of the device.
d
Speaker terminal cover Covers the speaker terminal.
Name Function Description
e
Screw A screw for securing the speaker terminal cover.
f
Safety cable hook Secures the speaker during installation to prevent it from falling.
g
Audio module Equipped with an audio module.
h
Gasket Dustproof/waterproof gasket.
i
Speaker housing Dustproof/waterproof speaker housing.
j
Bracket Secures the speaker to the ceiling board.

overview
8_ overview
NAMES AND FUNCTIONS OF THE IP SPEAKERS (WALL-MOUNT TYPE)
(SPA-W100B/SPA-W100W)
a
b
c
d
e
f
h
g
Name Function Description
a
Bracket Mounts the speaker on a wall.
b
Bracket fixing screw Secures the bracket.
c
Audio module Equipped with an audio module.
Name Function Description
d
Gasket Dustproof/waterproof gasket.
e
Speaker terminal cover Covers the speaker terminal.
f
Grounding port
Used for earth-grounding.
Grounding serves to protect the product from lightning strikes.
Before connection, be sure to turn off the power of the device.
g
Screw A screw for securing the speaker terminal cover.
h
Cable bushing Connects network and alarm cables.

English _9
!OVERVIEW
NAMES AND FUNCTIONS OF THE IP SPEAKERS (HORN TYPE)
(SPA
-
H100B/SPA
-
H100W)
a
b
c
d
PoE+
ALARM
OUT
IN
GND
RESET
STAT
e
g
f
Name Function Description
a
Bracket Mounts the speaker on a wall.
b
Bracket fixing screw Secures the bracket.
c
Waterproof plug Used for waterproofing when connecting the network and alarm cables.
d
Speaker terminal cover Protects the speaker terminals.
Name Function Description
e
Gasket Dustproof/waterproof gasket.
f
Audio module Equipped with an audio module.
g
Grounding port
Used for earth-grounding.
Grounding serves to protect the product from lightning strikes.
Before connection, be sure to turn off the power of the device.
M
`MicroSD card slot is not available.
`BGM or Chime sound sources can only be uploaded to the internal storage.

overview
10_ overview
NAMES AND FUNCTIONS OF THE IP SPEAKERS (PENDANT TYPE)
(SPA-P100B/SPA-P100W)
e
f
ALARM
OUT
RESET
IN
GND
PoE+
c
a
b
d
Name Function Description
a
Wire link Connected to the wire by using the provided carabiner.
b
Detachable grille Prevents dust intrusion.
c
Audio module Equipped with an audio module.
Name Function Description
d
Grounding port
Used for earth-grounding.
Grounding serves to protect the product from lightning strikes.
Before connection, be sure to turn off the power of the device.
e
Speaker terminal cover Protects the speaker terminals.
f
Screw A screw for securing the speaker terminal cover.

English _11
!OVERVIEW
BROADCAST SYSTEM CONFIGURATION DIAGRAM
Controller Mode Block Diagram
It is a block diagram for using the IP speakers in a controller mode.
The controller mode speaker provides an operating GUI which is different from a regular speaker, and it can
control multiple speakers via the button mode or event & preset menu.
You can configure a broadcast system by connecting the IP microphone (SPA-M1000) to it. Refer to the
separate manual for the IP microphone.
1
2
3
4
5
1 2 3
4 5 6
7 8 9
*0 #
VOLUME
MONITOR
MIC
TALK
PUSH
MAXMIN
AUX
MAXMIN
CHIME
MENU
PRESET
PREV
NEXT
CHIME
POWER
-6dB 0dB
NETWORK
+3dB +6dB
MAXMIN
ALL
Local PC
IP Speakers (ceiling-mount type)
IP Speakers (Pendant type)
IP Speakers (wall-mount type)
IP Speakers (Horn type)
IP Audio Module (Analogue Speaker)
<IP microphone>
IP Speaker (Controller mode)
Network
M
`You can use the IP audio server (SPA-S1000) as a controller.
`The IP audio module can be used as an IP speaker when connected to an analog speaker with a permissible input of 10W
or higher and an impedance of 8 ohms.
`There should be only one controller mode product in the broadcast system.
If multiple controller mode speakers or servers are registered redundantly, broadcasting cannot be performed properly.
Speaker Mode Block Diagram
You can run a scheduled broadcasting, BGM, or TTS broadcasting using each speaker by itself.
IP Speakers (ceiling-mount type)
IP Speakers (Pendant type)
IP Speakers (wall-mount type)
IP Speakers (Horn type)
IP Audio Module (Analogue Speaker)
Local PC
Network
IP PBX Linkage Block Diagram
You can broadcast voice to each speaker with a VoIP phone which uses the SIP protocol by using the IP
PBX server.
VolP Phone
(SIP)
IP PBX
IP Speakers (wall-mount type/Horn type)
IP Speakers (ceiling-mount type/Pendant type)
IP Audio Module (Analogue Speaker)
Network

overview
12_ overview
CONNECTING TO POWER AND A NETWORK
Connect the switching hub that supports PoE or PoE+ to the NETWORK port of the product using a network cable.
If you connect the product to a switching hub that supports PoE+ or PoE, you can use it without a separate power
source.
STATUS RESET
PoE+
ALARM
IN OUT
1
2
3
4
5
1 2 3
4 5 6
7 8 9
*0 #
VOLUME
MONITOR
MIC
TALK
PUSH
MAXMIN
AUX
MAXMIN
CHIME
MENU
PRESET
PREV
NEXT
CHIME
POWER
-6dB 0dB
NETWORK
+3dB +6dB
MAXMIN
ALL
Switching hub (PoE, PoE+ supported)
<IP audio module>
<IP microphone>
<IP Speaker>
J
`Use PoE+ switch hubs that support the IEEE 802.3at standard.
`Use PoE switch hubs that support the IEEE 802.3af standard.
Network Cable Specification
Item Contents Remark
Connector RJ45 (10/100BASE-T)
Ethernet 10/100BASE-T 10/100 Mbps
Cable Category 5e
Max Distance 100 m DC Resistance ≤ 0.125 Ω/m
PoE Support PoE+ / PoE

English _13
!START
starting
CONNECTING TO A PC
The PC should be connected to the same network as the product when accessing the product for the first time.
Use a network cable to connect the product to the switching hub that is connected with the PC.
M
`A speaker or an audio module is powered by PoE/PoE+. Use a switching hub that supports PoE or PoE+.
`The IP microphone can receive power via PoE, or the DC power adapter can be used.
ACCESS PRODUCT
Various functions, including Operation Mode, System Settings, Maintenance, Environment Setting, and Operation
Settings, are available on the product website.
1. Set an IP address to 192.168.1.x, the same band as the product, in the Network Property of the PC. (e.g.
192.168.1.100)
2. Run a web browser on the PC.
M
`An available web browser is Google Chrome (Version 92.0.4515.131 or higher).
Google Chrome is available at www.google.com/chrome.
`It can be used in Chrome as it is a supported web browser. For the computer OS, it can be used in Windows 10 or Mac
10.15 (Catalina) or 11 (Big Sur).
Product validation was performed on Windows 10 21H2 and the Mac 10.15.7 and 11.6 versions.
3. The initial IP address of all products is 192.168.1.99.
Before installing the product, it is recommended to set a static IP address for separate products.
M
`If multiple products are connected concurrently to the same switch hub with the initial IP addresses, the web page cannot
distinguish the IP addresses, resulting in failing to set passwords.
Use Device Manager to set the initial password and IP address to use.
Registering using Device Manager
If the product is connected to a network which includes a computer where the device manager is installed,
you can search products, set up passwords, change IP addresses, upgrade firmware, and access web
pages.
Please refer to the manual of the Device Manager Program for more information.
M
`The Device Manager Program ( ) is available on the official Hanwha Visionwebsite (https://www.HanwhaVision.com)
by clicking <Support> - <Online Tool>.
1. When you connect multiple products to the switch hub, their IP addresses are 192.168.1.99, and their
status information are queried as <Need PW>.
2. Select one or multiple products and set a password to use for each product.
~If they are not queried as <Need PW>, click <New Project> ;<Search>, and set the passwords after
they are queried as <Need PW>.
~If you set a password in the [Credential] menu and press [Search] on the list screen, the status
information is queried as <Connect Fail>.
~If you press <New Project> ;<Search>, the status information is queried as <Ready>. And if you
press <Search> again, it is queried as <Connect Fail>.
M
`A password should contain 8 or more characters, and if it contains fewer than 9 characters, then a combination of
3 or more English uppercase/lowercase letters, numbers, or special characters must be used. If it includes 10 to 16
characters, a combination of 2 or more types must be used.
`It is recommended not to use the same character repeatedly or consecutive keyboard inputs as passwords for enhanced
security.

start
14_ start
3. Select a product to set its IP address, and enter the IP address to use (e.g., Set Static IP).
When you select products one by one
~Select <Assign the following IP address> from the [IP Assign] menu, then set its IP address.
~The DNS server address is automatically set as the product’s initial DNS address (DNS1 8.8.8.8, DNS2
8.8.4.4).
When you select multiple products
~Select <Assign the following IP address> from the [IP Assign] menu. Then apply the starting address
in the range of IP addresses to be assigned.
J
`When you select <Obtain an IP address automatically (DHCP)> from the [IP Assign] menu, the DHCP IP address is
automatically assigned.
`The HTTP port supports only the number 80, and the VNP and RTSP ports are not used in the IP audio product.
4. Products with IP addresses must be logged in from the [Credential] menu to be queried as <Login OK>.
~When you execute <New Project> ;<Search>, authentication is canceled and the product is queried
as <Login Fail>.
J
`If you apply the product password in <System> ;<Device Default Credential setting> in the device manager, it is
automatically queried as <Login OK> even when you search for it as a new project or re-execute the device manager.
M
`You can update to the latest firmware for the product using the device manager.
`Check the firmware distribution information for each product on the Hanwha Vision website
(https://www.HanwhaVision.com) and download the latest firmware (modelname_version.imkp) to your PC.
You can also download the latest firmware to your PC from Device Manager.
1.
When selecting firmware for each product and running [Upgrade], the status will change to <50%> from
<Login OK>.

English _15
!START
2.
When the firmware update is completed and the system is rebooted, the status will change to <Please wait
until the program starts.>. After it reaches 100%, it will change to <Success>
3.
If you update multiple products at the same time, the update will proceed sequentially by four units at a time.
Registering with the product’s initial IP address
If you connect only one product to the switch hub, it is possible to set up the password even on the web
page.
1. Enter the product’s initial IP address into the web browser’s address bar.
2. The admin account password must be registered when accessing the product for the first time.
When the <Change Password> window appears, please enter a new password.
J
`A password should contain 8 or more characters, and if it contains fewer than 9 characters, then a combination of
3 or more English uppercase/lowercase letters, numbers, or special characters must be used. If it includes 10 to 16
characters, a combination of 2 or more types must be used.
`It is recommended not to use the same character repeatedly or consecutive keyboard inputs as passwords for enhanced
security.
3. A product login screen appears after successfully setting the password.

start
16_ start
LOGGING IN
Use the password set for the admin account.
1. Enter “admin” in the <ID> field.
2. Enter a password in the <Password> field.
3. Click the [Login] button to move to the Home screen of the product.
After 30 minutes of inactivity on the website, you will be automatically logged out.
J
`If you forget the password, the product has to be initialized by pressing the RESET button for about 12 seconds. Therefore,
make sure to write your password down or remember it.
If you have already logged in, the system can be initialized in the <Environment Setting> ;<System Management>
menu of the web page.
`Do not disconnect the power until the system initialization is complete after pressing the [RESET] button of the product
or during product resetting. It will take up to 10 minutes to reboot the product after initializing it.
M
`To change the network settings according to the user's network connection configuration, use the <Network Setting>
function in <Environment Setting>. (Page 19)
`Available accounts are divided into admin, setup, user, and guest by access authority level. Go to <Environment
Setting> ;<System Management> ;<Change Password> to change the passwords of each account. (Page 17)
`A maximum of five users can log in to the product at the same time. The <Exceed the maximum user> screen will
appear if there is an attempt to log in while the maximum number of users are logged in, and it will show the currently
connected PC IP addresses.

English _17
!ENVIRONMENT SETTINGS
The environment setting menu is a feature which is provided for both the controller-mode speaker and regular
speaker.
SYSTEM MANAGEMENT
Various functions are available, including System Upgrade, Change Password, System Check, Restart, and Reset.
Upgrading the System
1. Click <Environment Setting> ;<System Management> on the Home screen.
2. Click the [Upload] button in <System Upgrade>.
3. Select the upgrade file (model name_version.imkp) that you downloaded from the official Hanwha Vision
website (https://www.HanwhaVision.com) in advance and click [Open].
4. Click [Apply] to start System Upgrade. Click <OK> when the “System Restart” window appears after up
to five minutes.
J
`If you close the web browser or move to another menu before the “Restart the Program” message pops up, it may not be
updated.
`Do not disconnect the power in the middle of a system upgrade. Doing so may cause malfunctions.
5. It will take up to 10 minutes to upgrade the system and reboot the product.
The software version information of the product is available in the upper-right corner of the Home screen.
Changing the Password
You can change the passwords of each account.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. By clicking <Destination Account> from <Password Change>, select the account you want to change
and set the password.
3. Click the [Apply] button after entering a new password in the two input fields.
4. The admin account can be changed if you enter the previous password.
If you forgot the previous password, the product has to be initialized, and the passwords for all the
accounts will be initialized during the process.
5. The password of the setup, user, and guest accounts can be set, changed, or reset from the admin
account if they are forgotten.
Viewing the supported menu by account
To prevent any confusion due to arbitrary changes to the settings and to continue stable maintenance of the
system, access rights are differentiated by account, and all restricted features for each account are disabled
on the screen.
[Controller mode]
Home screen Operate Maintenance System Setting Environment Setting
admin
setup
user
guest
environment settings

environment settings
18_ environment settings
- admin: You can use all the functions of the product.
- setup: You can use all the functions except for environment settings, such as System Upgrade,
Change Network, Change Time, etc.
- user: Broadcast ON/OFF operation and product monitoring are available, and log records can be
checked.
- guest: You can check the product information on the home screen.
[Speaker Mode]
Home screen Operation Setting Maintenance Environment Setting
admin
setup
user
guest
- admin: You can use all the functions of the product.
- setup: You can use all the functions except for environment settings, such as System Upgrade, Change
Network, Change Time, etc.
- user: Speaker operation settings are available except DSP Settings, Annual Scheduler, and SIP Settings, ,
and the log history can be checked.
- guest: You can check the product information on the home screen.
Unlock Account
For all accounts except the admin account, if you enter the wrong password more than 5 times when logging
in, the account will be locked for 30 seconds and you will not be able to log in.
The admin account can reset the number of retries by checking the number of login retries for each account
and whether the account is locked.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. Click [Reset] after checking the locked account on <Account lock status> The lock icon is changed to
unlocked and the number of retries for the account is reset.
Setting the System Check Time
Sets the time for the system check. The system reboots automatically at the set time every day.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. Set the time to start checking in <System Check Settings>
3. Click [Apply] after clicking the [ ] button of <Operation>.
4. The system will be checked and be rebooted at the set time; it will take approximately 5 minutes.

English _19
!ENVIRONMENT SETTINGS
Restarting System
You can restart the system without disconnecting the power when a system reboot is needed.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. Click the [Apply] button in <System Restart>.
3. Click <OK> when the system restarting window appears.
It will take approximately 5 minutes to reboot the system.
Resetting the System
Initializes every system setting to the factory default values.
An IP address of the product is also initialized to the initial status, which is 192.168.1.99.
Please re-open the web page and access 192.168.1.99.
Even the power mode and operation mode become the PoE, which is the initial state and speaker mode.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. If you click the [Apply] button of the <All> item on <Factory Default Setting>, all set values will be reset,
and if you click the [Apply] button of the <Network status maintain> item, all set values except for
network information will be reset.
3. Click <OK> when the factory default window appears. Product initialization starts.
4. Click <OK> when the system start window appears on the web browser.
J
`Do not disconnect the power until the factory default settings are restored.
It will take up to 10 minutes to restart and complete the execution of the internal daemon program after product
initialization.
• When the system initialization is completed, previously registered product information should
be deleted from the controller mode speaker or audio server (SPA-S1000), and you must
register if you wish to use the product.
• As the log information will be deleted when the product's system is initialized, please
download it in advance.
NETWORK SETTINGS
You can change the network settings according to the user's network connection configuration.
1. On the Home screen, click <Environment Setting> ;<Network Setting>.
~On the <Common network configurations setting>, the <Device Name> is displayed as <Name> on
the device manager's query list.
~You can enter the location of installation in <Device Location> in <Common network configurations
setting> (e.g. 6th floor, Main Building)
~You can enter the IP address, subnet mask, gateway, DNS 1 and DNS 2 server addresses for the product
by selecting <User Setting> in <Network Setting>.
`MAC address: The unique physical address of the product. (e.g. Starts with 00:1d:1d.)
`IP address: Enter the IP address available in your network band.
`Subnet mask: The subnet mask of the set IP address is indicated.
`Gateway: The gateway of the set IP address is indicated.
`DNS 1 server, DNS 2 server: Enter the primary DNS address and secondary DNS address.
~The IP, subnet mask, gateway, DNS 1 and DNS 2 server addresses for the product will be allocated
automatically from the DHCP server by selecting <DHCP Setting> in <Network Setting>.
~Click [Apply] to apply the set network information to the product.
~Click [Cancel] to return to the most recent status before changing settings.
J
`The system restarts automatically if the network settings are changed.

environment settings
20_ environment settings
TIME SETTINGS
Set the time and date accurately or it may cause problems in operating the broadcast.
1. On the Home screen, click <Environment Setting> ;<Time Setting>.
~The current time is set if you select GMT of your location on <Standard Time Zone>
~For the local network which is not connected to the external Internet, select <Manual Setting> in <Time
Setting> and enter the time manually to use it.
~If it is connected to the external Internet, select <Auto Configuration> in <Time Setting> to synchronize
the time to the standard time of the time server.
~For the domain address in the <Time Server Address> input field, use time.google.com / time.apple.com
/ pool.ntp.org / north-america.pool.ntp.org / time.bora.net / clock.isc.org.
~Please check if the domain address provides time information which reflects Daylight Saving Time.
~<Next Synchronization Time> automatically changes from the previously synced time every 8 hours.
~Click [Synchronize Now] to synchronize the time to the time server.
2. Click [Apply] to apply the set Time and Date information.
J
`If the product is used in a local network environment without an external Internet connection, the time information may
become incorrect due to the product's accumulated time errors. To accurately schedule the broadcasting time, we
recommend installing a separate time server device using GPS signals or enter the audio server IP (SPA-S1000) with high
time accuracy into the <Time Server Address> field of other products to synchronize the time information with the audio
server.
`If there is a product connected to an external Internet, enter the IP address of the product in the <Time Server Address>
field of other products before using them.
`IP audio products are not synchronized with the OS time of the PC.
M
`If the product is used in a local network environment without the external Internet connection, Daylight Saving Time is not
automatically reflected as it is not synchronized with an external time server.
`In countries where Daylight Saving Time is applicable, it is recommended for the system administrator to use the product
by changing the time manually for the start and end dates of the Daylight Saving Time.