Hanyoung BS Series User manual

MG0202E050604
Model Name and Structure
Measuring Range Code
Before you use, read safety precautions carefully, and use this product
properly. The precautions described in this manual contain important
contents related with safety; therefore, please follow the instructions
accordingly. The precautions are composed of DANGER, WARNING
and CAUTION.
There is a danger of occurring electric shock in the input/output
terminals so please never let your body or conductive substance is
touched.
1. This product does not contain an electric switch or fuse, so the user
needs to install a separate electric switch or fuse externally. (Fuse
rating: 250 V 0.5 A)
2. To prevent defection or malfunction of this product, apply a proper
power voltage in accordance with the rating.
3. To prevent electric shock or malfunction of product, do not supply
the power until the wiring is completed.
4. Since this product is not designed with explosion-protective
structure, do not use it any place with flammable or explosive gas.
5. Do not decompose, modify, revise or repair this product. This may
be a cause of malfunction, electric shock or fire.
6. Reassemble this product while the power is OFF. Otherwise, it may
be a cause of malfunction or electric shock.
7. If you use the product with methods other than specified by the
manufacturer, there may be bodily injuries or property damages.
8. There is a possibility of occurring electric shock so please use this
product after installing it onto a panel while it is operating.
1. The contents of this manual may be changed without prior
notification.
2. Before using the product you purchased, make sure that it is
exactly what you ordered.
3. Make sure that there is no damage or abnormality of the product
during the delivery.
4. Do not use this product at any place with occurring corrosive
(especially noxious gas or ammonia) or flammable gas.
5. Do not use this product at any place with direct vibration or impact.
6. Do not use this product at any place with liquid, oil, medical
substances, dust, salt or iron contents. (Use at Pollution level 1 or 2)
7. Do not polish this product with substances such as alcohol or
benzene. (Use neutral detergent.)
8. Do not use this product at any place with a large inductive difficulty
or occurring static electricity or magnetic noise.
9. Do not use this product at any place with possible thermal
accumulation due to direct sunlight or heat radiation.
10. Install this product at place under 2,000m in altitude.
11. When the product gets wet, the inspection is essential because
there is danger of an electric leakage or fire.
12. If there is excessive noise from the power supply, using insulating
transformer and noise filter is recommended. The noise filter must
be attached to be a panel grounded, and the wire between the filter
output side and power supply terminal must be as short as
possible.
13. If putting the power cables closely together then it is effective
against noise.
14. Do not connect anything to the unused terminals.
15. After checking the polarity of terminal, connect wires at the correct
position.
16. When this product is connected onto a panel, use a circuit breaker
or switch approved with IEC947-1 or IEC947-3.
17. Install a circuit breaker or switch at near place for convenient use.
18. Write down on a label that if the circuit breaker or switch is
operating then the power will be disconnected since the circuit
breaker or switch is installed.
19. For the continuous and safe use of this product, the periodical
maintenance is recommended.
20. Some parts of this product have limited life span, and others are
changed by their usage.
21. The warranty period for this product including parts is one year if
this product is properly used.
Safety information
WARNING
CAUTION
DANGER Suffix code
MODEL Description
BS3 (72 36 107 mm)
BS6 (96 48 109 mm)
Display Only
AC: Measuring AC
DC: Measuring/Input Scaling DC
Voltage
Current
Displaying Measured Value
Displaying Input Scale Value
Measure/Input Display Range
See Range Code
Average Value Measurement
NA
D1
20
1
S
BS
Display
Measuring/Input
Power Type
Voltage/Current
Display Measured
Value/Input Scale Value
Measure/Input Range
Measurement Method
HEAD OFFICE
1381-3, Juan-Dong, Nam-Gu Incheon, Korea
TEL:(82-32)876-4697 FAX:(82-32)876-4696
MAIN PRODUCTS
- DIGITAL : Temperature Controller, Counter, Timer,Speedmeter,
Tachometer, Panel Meter, Recorder
- SENSOR : Proximity Sensor/Photo Electric Sensor,
Rotary Encoder, Optical Fiber Sensor,
Pressure Sensor
- ANALOG : Timer, Temperature Controller
Digital Panel meter
BS series
We appreciate you for purchasing HanYoung NUX Co.,Ltd
product. Before using the product you have purchased,
check to make sure that it is exactly what you ordered. Then,
please use it following the instructions below.
INSTRUCTION MANUAL
AC Voltage Measurement
Measuring
Range
1.999 V
19.99 V
199.9 V
400 V
199.9 mV
1.999 V
19.99 V
199.9 V
400 V
Resolution
1 mV
10 mV
100 mV
1 V
1 mV
1 mV
10 mV
100 mV
1 V
Input
Impedance
1
100
10
10
1
1
100
10
10
Max Permissible
Input Voltage
10 V
50 V
300 V
500 V
10 V
10 V
50 V
300 V
500 V
AC
Voltage
NA10
NA10
Range
Code
1
2
3
4
1
2
3
4
5
Model
BS3
BS6
AC Current Measurement
Measuring
Range
19.99 mA
199.9 mA
1.999 A
5.00 A
19.99 A
30.0 A
100.0 A
150.0 A
199.9 A
300 A
1999 A
Resolution
10
100
1 mA
10 mA
10 mA
100 mA
100 mA
100 mA
100 mA
1 A
1 A
Input
Impedance
10
1
0.1
40
Max Permissible
Input Current
50 mA
300 mA
3 A
5 A
Use current
transformer (CT)
(Secondary Current 5A)
DC Voltage Measurement
Measuring
Range
199.9 mV
1.999 V
19.99 V
199.9 V
500 V
Resolution
0.1 mV
1 mV
10 mV
100 mV
1 V
Input
Impedance
470
100
1
10
10
Max Permissible
Input Voltage
70 V
100 V
200 V
300 V
400 V
AC
Current
NA20
Range
Code
1
2
3
4
5
6
7
8
9
10
11
Model
BS3
BS6
DC
Voltage
ND10
Range
Code
1
2
3
4
5
Model
BS3
BS6

Aspect & Panel Cutout Dimension
Unit : mm
CAUTION
Input Signal
A/D Conversion Method
Sampling Cycle
Response Time
Max Displayable Digit
Display
External Control
Accuracy
Power Supply
Power Consumption
Insulation resistance
Dielectric Strength
Vibration
resistance
Shock
Resistance
Operating Ambient Temperature
Operating Ambient Humidity
Storage Ambient Temperature
Malfunction
Durability
Malfunction
Durability
Current, Voltage, Instrumentation Signal Input
(4~ 20 mA DC, 1 ~ 5 V DC)
Double Integral Method
300 ms
Approx. 2 sec (Max Range)
3 1/2 digit (1999)
7 segment LED, Character Height 20.4 mm
Hold function
AC Voltage: 0.5 % of FS 1 digit
DC Voltage: 0.2 % of FS 1 digit
110 V AC / 220 V AC (50/60 Hz common)
(Voltage Fluctuation Rate 10 %)
Approx. 2 VA (at Max Load)
Between each terminal 500 V DC , above 100
1500 V AC for 1 minute (between power terminal
and input terminal)
10 ~ 50 Hz single amplitude each X YZ
direction for 2 hours
10 ~ 50 Hz single amplitude each X YZ
direction for 10 minutes
300 m/s2(approx. 30 G)
100 m/s2(approx. 10 G)
0 ~ 50
35 ~ 85 %
-10 ~ 70
Specification
Front Parts Name
Wiring Diagram
Measuring Method of AC
DC Current Measurement
Measuring
Range
1.999 mA
19.99 mA
199.9 mA
1.999 A
199.9 mA
1.999 mA
19.99 mA
199.9 A
5.00 A
19.99 A
199.9 A
1999 A
Resolution
1
10
100
1 mA
1
10
100
1 mA
10 mA
100 mA
100 mA
1 A
Input
Impedance
100
10
1
0.1
100
10
1
0.1
40
Max Permissible
Input Current
50 mA
150 mA
300 mA
3 A
50 mA
150 mA
300 mA
3 A
5 A
Use shunt (Secondary
Voltage 50 mV (standard))
DC Voltage Input scale Display
Input
Range
1 ~ 5
V DC
Display
Range
50.0
100.0
199.9
Input
Impedance
500
500
500
Max Permissible
Input Voltage
100 V
100 V
100 V
DC Current Input scale Display
Dimension Table
BS3
BS6
Input
Range
4 ~ 20
mA DC
Display
Range
50.0
100.0
199.9
Input
Impedance
25
50
500
Max Permissible
Input Current
150 mA
150 mA
150 mA
SPAN.VR ZERO.VR
[Note] It is easy to adjust since there are SPAN.VR in the left and
ZERO. VR in the right after opening its cover.
Please use a single contact when using hold function of AC
voltage/current type. Terminal 3 and 4 are internally shorted so that it
can be a cause of its malfunction when connecting them in parallel.
CAUTION
Please use a single contact when using hold function of AC
voltage/current type. Terminal 2 and 3 are internally shorted so that it
can be a cause of its malfunction when connecting them in parallel.
When measuring AC voltage and current, there are two methods which
are measuring effective values method and measuring average values
method. If the input is not followed a sine wave or is having lots of
distorted waves then it is useful to measure effective value but
measuring average values method is generally used for measuring.
(For analog meter, most of them take measuring average values
method.) The factory default of Hanyoung NUX.’s DPM is measuring
average values method as standard feature.
DPM : Digital Panel Meter
Cover
Display
Window
Model
BS3
BS6
ABCDEFGHI JKLMN
96 48 102 48 7 91 11 28 13 44.8 45 92 60 130
72 36 100 36 6.5 89 11 16 12 30.5 31 66.5 60 100
A
B
EF G
H
I
C
J
D
K
L
M
N
DC
Current
ND20
ND20
ND20
Range
Code
1
2
3
4
1
2
3
4
5
6
7
8
Model
BS3
BS6
BS3
BS6
DC
Voltage
ND11
Range
Code
1
2
3
Model
BS3
BS6
DC
Current
ND21
Range
Code
1
2
3
Model
BS3
BS6
This manual suits for next models
2
Popular Measuring Instrument manuals by other brands

Iridex
Iridex Cyclo G6 Operator's manual

Super Systems
Super Systems H2-SGA Operation manual

Doculus Lumus
Doculus Lumus Doculus Lumus+ quick guide

Baker Hughes
Baker Hughes Waygate Technologies CL 5 operating manual

LaserLiner
LaserLiner PowerCross-Laser 5G DLD manual

biochrom
biochrom Ultrospec 3300 pro manual

SSI
SSI DPL4000 Operation manual

Network Instruments
Network Instruments GigaStor Portable user guide

THEIS
THEIS TKL-7 operating instructions

Tractel
Tractel dynafor HHD Installation, operating and maintenance manual

LaserLiner
LaserLiner SuperLine 2D operating instructions

Vanguard Instruments Company
Vanguard Instruments Company CT-6500 2 Series operating instructions