Hapi LS202-B User manual

User Manual

Contents
Safety Information ..................................................................3
Safety and Usage Information ..........................................................3
Regulatory Statements on Proper Handling and Intended Use ......................3
Overview ................................................................................5
Device Components.....................................................................5
LCD Display .............................................................................5
General Instructions...............................................................6
Insert the Batteries ......................................................................6
Pairing and Setting Up a Prole with the HAPI Connect Mobile App .................7
Setting Up Your Prole and Multiple Users on the Scale ..............................8
Initialising the Scale ...................................................................10
Weight-Only Operationt ...............................................................10
Start Measuring....................................................................11
First Measurement ....................................................................11
Daily Measurement....................................................................12
Manage Your Health..............................................................13
Syncing Data ..........................................................................13
Activate Your Free Nutritional Coaching Program on HAPIcoach ..................14
Troubleshooting ...................................................................15
Error Messages........................................................................15
When Measuring ......................................................................15
During Data Syncing ..................................................................16
Specications ..........................................................................17
About the accuracy of this product ...................................................17
Maintenance.........................................................................18
Warranty ..............................................................................19
Appendix..............................................................................19
Health Tips - About Body Fat .........................................................19
Standard for Men ......................................................................19
Standard for Women ..................................................................20
Health Tips - About Body Water ...................................................... 20
Health Tips - About Muscle Mass .....................................................21
Muscle Mass Percentage .............................................................21
Health Tips - About Bone Mass .......................................................21
EMC Guidance ........................................................................21

3
Safety Information
Safety and Usage Information
The warning signs and symbols are essential to ensure your correct and safe use of this product and
protect you and others from injury. Here are the meanings of the warning signs and symbols, which you may
encounter in the label and user manual, as follows:
Regulatory Statements on Proper Handling and Intended Use
To ensure you use your product correctly and safely, read and heed these warnings and the entire user
manual before using the product.
The HAPI Connected Scale with Smart Body Analyser (also known as the HAPI Connected Smart Body
Analyser) offers you a seamless way to manage your health.
Please be aware that this device is designed for healthy individuals over 10 years old to measure their weight
and monitor their body composition. Any information provided by this device is in no way meant to treat, cure,
or prevent any disease or illness from happening. If in doubt, contact your physician.
This device is contraindicated for any female user who may be suspected of being, or is pregnant. Otherwise,
the effects of this device on the fetus are unknown.
This device is contraindicated for any person who is connected to a wearable or implantable electronic
device or instrument, such as a pacemaker or debrillator.
This device should not be used for anyone who is acutely or chronically ill because of suffering from a
disease or taking medications that affect water levels. The accuracy of readings for these patients has not
been veried. Specic medical advice should be obtained from a physician.
This connected scale is equipped with data transmission function. It may emit electromagnetic energy so as
to perform its intended function. Nearby portable and mobile RF communications equipment can affect the
performance of the connected scale. And the device can interfere with electrical equipment in the vicinity.
The manufacturer will make available on request circuit diagrams, component parts list, etc.
Important
The Bluetooth logo
Complies with EU requirements
Manufacture date
Serial number
Manufacturer
Direct current
ENVIRONMENT PROTECTION
Discarded electrical products should
not be disposed of with household
waste. Please recycle where facilities
exist. Check with your local authority
or retailer for recycling advice.

4
WARNING:
No modications of this equipment is allowed. This may result in increased emissions or decreased lifetime
of the scale.
Please use the device according to the user manual. Any misuse can cause electric shock, burns, re, and
other unexpected hazards.
Please use and storage the device under the environment which was provided in the user manual.
Don’t expose the device to extreme temperatures, direct sunlight, moisture, or corrosive environments.
Do not step on the scale when your body or feet are wet, especially after bathing or showering, to prevent
slipping.
Please keep the device out of reach of infants, children or pets, since inhalation or swallowing of small parts
is dangerous or even fatal.
Please don’t use the device past its lifetime, as degraded sensors and electrodes, or
loosened electrodes can degrade performance or cause other problems.
If you have an allergy to stainless steel, please avoid contact with the electrodes of the device.
The user of this connected scale can measure, transmit data and charge battery under
normal circumstances and maintain the device and its accessories according to the user manual.
INDICATIONS FOR USE
The HAPI Connected Scale with Smart Body Analyser measures weight and uses bio-electrical impedance
analysis (BIA) technology to estimate body fat, total body water percentage, bone mass, and muscle mass
in generally healthy children between 10 to 17 years old and healthy adults.
It is intended for personal use at home only.
Tips
To ensure the accuracy of measurement,
please follow the instructions below when
you start your measurement.
• Place the scale on a at, hard surface. A
soft surface, like a carpet, will affect the
performance of the scale.
• Step onto the platform with bare feet. Stand
still and keep full contact with the electrodes
until the measurement is complete.
• Weigh in at least two hours after waking up or
eating a meal.
• Avoid weighing in immediately after strenuous
exercise, sauna or bath, drinking, and eating.
• Always weigh in at the same time slot and with
the scale at the same location and at, hard
surface.
• For maximum accuracy and consistency, it is
recommended that you should use the device
in the same time of the day and at the same
location.
• Body fat percentage estimates will vary with the
amount of water in the body, and can be affected
by dehydration or over-hydration due to factors
such as alcohol consumption, menstruation,

5
Device Components
LCD Display
SET
HAPI
Overview
LCD Display
Down Key
Set Key
Up Key
Body Fat Analysis Result
Water Analysis Result
Muscle Mass Analysis Result
Bone Mass Analysis Result
Male
Female
Male Athlete
Female Athlete
Height
User ID (Range from U1 to U8 )
Age
Centimeter
Foot
Stone
Pound
Kilogram
Percentage
Successful Bluetooth Connection
Data transmitting / pending to transmit to
wireless wellness system
Low Battery
Pair-Up
Pair-Up succeeded
Pair-Up failed
UNIT Button
Battery
Compartment

6
• Insert the batteries (4 x 1.5V AAA) into the battery
compartment according to the polarity indications
marked inside the compartment.
*The digits “ ” will be shown on the LCD.
• Close the battery door and wait until the digits “ ”
are shown on the LCD.
General Instructions
The HAPI Connected Smart Body Analyser applies BIA (bio-impedance Analysis) technology. A weak current
ows through the human body to detect bio-impedance and estimate body fat, body water, muscle mass
and bone mass. The electrical current is small and cannot be felt. This BIA technology is cheap, safe, non-
invasive, toxic-free and harmless. It also possesses the characteristics of simple operation and abundant
information.
The current mentioned above is less than 0.5mA. However, please be aware that anyone with a wearable or
implantable medical electronic instrument, such as a pacemaker, must avoid using this device.
The intended use of this device is for healthy children from 10 to 17 years old and healthy adults.
Insert the Batteries
• Open the battery door at the bottom of the scale.
CAUTION
When the symbol appears, the device will power off. This indicates that you will need to replace the
batteries. Please replace all four batteries at the same time. Do NOT mix the old batteries with the
new ones.
Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage.
Please refer to the local ordinances and recycling instructions regarding disposal of the worn
batteries and device.
If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the
batteries before storing.

7
Pairing and Setting Up a Profile with the HAPI Connect Mobile App
With the advanced Bluetooth 4.0 technology installed, mobile devices such as smartphones or tablets which
are equipped with the BLE Technical Specications established by global organization Bluetooth SIG, are
capable to receive your personal health data.
1. Search for HAPI Connect on the App Store for iOS
Devices and Google Play for Android devices.
%
SET
X
2. Turn on Bluetooth in your device’s settings. Run the
HAPI Connect app once installation has nished.
3. Register for an account with your e-mail address
and set up your prole by following the on-screen
instructions.
4. In the HAPI Connect app’s main menu, tap on Device
and + Add Device
5. At the bottom of the Connected Scale, press and hold
the UNIT button.
6. “ ” on the scale’s LCD indicates the pairing process
is in progress.
7. If pairing is successful, this “ ” will be shown on
the LCD, and you will be prompted to assign a slot or
user ID (P1-P8) to the prole on the mobile app.
8. If the pairing failed, E1 will be displayed on the LCD.
Repeat from step 4 to try again.

8
SET
SET
Setting Up Your Profile and Multiple Users on the Scale
The HAPI Connected Body Analyser supports multiple users (up to 8). If you have a mobile phone running
Bluetooth 4.0, you can congure and assign these user IDs using the HAPI Connect app and the process
described in the previous page. Otherwise, you can follow the instructions below to assign a user ID and set
up a prole on the device itself.
1. Assigning a user ID
• With the batteries correctly installed, press the SET
key.
• You can now select a user ID, as indicated by P1-P8.
You can tap the arrow keys < > to select the user ID.
• Once selected, press SET to conrm
2. Setting gender
• After conrming the user ID, you can set the gender
for this prole
• The gender icon will blink to indicate that this can
be edited. Tap on the arrow keys to run through
the selections (male, female, male athlete, female
athlete)
• Once selected, press SET to conrm.
3. Setting height
• After selecting the gender, you can set the height for
this prole.
• The digits 165 will blink on the display. Tap the arrow
keys to adjust accordingly (100 to 220 cm or 3’ 3.5”
to 7’2.5”)
• You can press and hold on the arrows to adjust the
numbers faster.
• Once you’ve nished entering the height, press SET
to conrm.
Athlete mode:
An athlete is dened as an adult who is involved in
intense physical activity of approximately 12 hours
per week, and with a resting heart rate of 60 beats per
minute or fewer.

9
4. Setting age
• After entering the height, you can set the age for this
prole.
• When the digits 30 blink, you can press the arrow
keys to adjust the age.
• You can press and hold on the arrows to adjust the
numbers faster.
• Once you’ve nished entering the age, press SET to
conrm.
When the LCD displays 0.0, you can weigh in.
Selecting the Measurement Unit
With the batteries correctly installed, press the UNIT
button at the bottom of the scale to scroll through the
measurement units. The default measurement unit
is kilograms. You can press UNIT to select kilograms,
pounds, and stone.

10
SET
Initialising the Scale
If your rst weight reading was inaccurate, you may need to initialise the scale. This process is necessary
because the scale was moved during the shipping process. Initialising the scale “re-seats” the internal parts,
allowing the scale to nd the correct “zero.” Here is how to initialise your scale:
This initialisation process must be repeated if the scale is moved. At all other times, step straight on the scale.
Weight-Only Operation
The HAPI Connected Body Analyser can also operate as a conventional weight-reading scale. No special
programming steps are required.
Once the scale is initialised, as previously described, you can simply step on the scale to measure your
current weight. In this process, weight is the only measurement that is taken.
1. Position the scale on a at, hard surface. Carpeted or uneven oors may affect accuracy.
2. Step onto the scale platform and remain still while the scale measures your weight.
3. The scale will display your weight.
4. The scale will automatically turn off after a few seconds.
Note: The weight taken from this operation will not be saved in the scale’s onboard memory and will not be
transmitted to the app.
1. Place the scale back on a hard surface oor.
3. 0.0 will be displayed
2. With only one foot, step on the platform and
remove your foot.
4. The scale will switch off and is now ready for use.
SET
SET
Table of contents