manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Harman
  6. •
  7. Gateway
  8. •
  9. Harman AMX DR-GW1000 User manual

Harman AMX DR-GW1000 User manual

Other Harman Gateway manuals

Harman NXB-KNX User manual

Harman

Harman NXB-KNX User manual

Harman IoT-GW-02 User manual

Harman

Harman IoT-GW-02 User manual

Harman AMX NetLinx Clear Connect NXB-CCG User manual

Harman

Harman AMX NetLinx Clear Connect NXB-CCG User manual

Popular Gateway manuals by other brands

Telecom FM onestream gfx Programming guide

Telecom FM

Telecom FM onestream gfx Programming guide

UfiSpace LoRa GPE810U Quick setup guide

UfiSpace

UfiSpace LoRa GPE810U Quick setup guide

Merak MMk-736F Quick setup guide

Merak

Merak MMk-736F Quick setup guide

Robustel R3010 user guide

Robustel

Robustel R3010 user guide

turck BL20-PG-EN-V3 user manual

turck

turck BL20-PG-EN-V3 user manual

IBM Security Web Gateway Appliance quick start guide

IBM

IBM Security Web Gateway Appliance quick start guide

SSS Siedle Smart Gateway Commissioning instructions

SSS Siedle

SSS Siedle Smart Gateway Commissioning instructions

ADTRAN 424RG Installation

ADTRAN

ADTRAN 424RG Installation

Chorus Hyperfibre XGS-250WX-A user guide

Chorus

Chorus Hyperfibre XGS-250WX-A user guide

Dragino G308 user manual

Dragino

Dragino G308 user manual

Data Domain DD690g Installation and setup guide

Data Domain

Data Domain DD690g Installation and setup guide

Raritan Laptop Release notes

Raritan

Raritan Laptop Release notes

Haivision Torpedo quick start guide

Haivision

Haivision Torpedo quick start guide

ATCOM AG-268 user manual

ATCOM

ATCOM AG-268 user manual

LST M500RFE-AS Specification sheet

LST

LST M500RFE-AS Specification sheet

Vega VEGA BS-3 user manual

Vega

Vega VEGA BS-3 user manual

Kinnex Media Gateway quick start guide

Kinnex

Kinnex Media Gateway quick start guide

2N Telekomunikace 2N StarGate user manual

2N Telekomunikace

2N Telekomunikace 2N StarGate user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DR-GW1000
DIN RAIL MOUNTED ETHERNET GATEWAY
DR-GW1000 is a DR-Link protocol compliant
Ethernet gateway designed for use with Direct
Series lighting control modules and is capable of
auto acquiring online devices within the range and
monitoring and reporting any operation error of the
lighting system.
• Designed for standard 35mm DIN rail installation [Space Occupa-
tion: 4P (per P:18mm)].
• Online upgrading.
• Communication through DR-Link interface and capaple of auto
acquiring online devices and monitoring and reporting operation
errors.
• Two DR-Link interfaces connects up to 63 DR-Link devices.
• An extended control system can be set up through ethernet connec-
tion with IPad, Andriod touch panel or AMX controller.
• Data import/export.
• Local or remote data download through Ethernet connector.
1. LED Indicators and Control Buttons:
• POWER: indicates status of power supply.
• LINK: indicates status of control interface. When solid on, the
control interface is operating correctly; When blinking, a fault
appears to the control interface.
• RESET: resets IP to factory default (192.168.1.230:6000).
Press for 6 seconds and wait till the LINK LED stops blinking.
Then the resetting is successful.
• CLEAR: clears all setting data from the module. Press for 6
seconds and wait till the LINK LED stops blinking. Then all
the setting data are successfully erased.
2. DR-Link Interface: 24V, G, A, B.
3. RS232 Interface: uses a Phoenix terminal to connect a RS232
device. Port parameter: 115200,n,8,1.
4. Control Keypad Interface: uses a RJ45 connector (with LED indica-
tors) to connect a control keypad. The cable connected should be
wired to 586B standard.
5. Electrical box Interface: uses a RJ45 connector (with LED indica-
tors) to connect an electrical box. The cable connected should be
wired to 586B standard.
6. ETHERNET Interface: uses a RJ45 connector (with LED indicators)
to connect a router. The cable connected should be wired to 586B
standard. The two ETHERNET connectors can not be used simulta-
neously. Please choose only one of the two to connect.
FEATURES STRUCTURE
SPECIFICATIONS
Power supply DC 24V 90 mA
Control interface 2 × DR-Link
Ethernet 1 × RJ45 connector (with LED indicators)
Cascade connection 1 × RJ45 connector (with LED indicators)
Control keypad 1 × RJ45 connector (with LED indicators)
LED indicators 1 × POWER, 1 × ETHERNET, 1 × LINK
Connectivity Support up to 63 DR-Link devices
Control buttons 1 × RESET, 1 × CLEAR
Downloading 1 × Ethernet connector
Operation temperature / RH 0˚C - 45˚C / 20% - 93% RH
Storage temperature / RH -40˚C - +55˚C / 10% - 93% RH
Dimensions (L x W x H) 72 mm × 98 mm × 68 mm (4P)
Weight 190 g/pcs
ETHERNET
4
3
6
6
2
2
5
路
由
接
口
电箱级联
电
箱
级
联
1
DIRECT SERIES LIGHTING CONTROL MODULE
ETHERNET
68
9
8
72
measured in mm
• Read this document carefully before use.
• Ensure the product is well ventilated.
• Avoid moisture, vibration and dust.
• Do not expose the product to rain, any types of liquid or corrosive
gases.
• Dry the product immediately if it’s affected by damp or splash.
• Refer all servicing to qualified service personnel or AMX if a prod-
uct fault appears.
© 2017 Harman. All rights reserved. ENZO, NetLinx, AMX, AV FOR AN IT
WORLD, HARMAN, and their respective logos are registered trade-
marks of HARMAN. Oracle, Java and any other company or brand name
referenced may be trademarks/registered trademarks of their respective
companies.
AMX does not assume responsibility for errors or omissions. AMX also
reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be
viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082
AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax
469.624.7153
WIRING OF SINGLE MODULE READE BEFORE USE
CONTACTWIRING OF MUTIPLE MODULES
DR-GW1000
062017
ETHERNET
To a network switch or router
To a cotrol module To a cotrol module
To a RS232 device
To an electric box To an electric box
Only one Ethernet connector
can be used. For RS232 operation,
switch ON 1&2 and
switch OFF 3&4.
ETHERNET
DR-8SW16A
CHANNEL 16A RELAY SWITCH MODULE
8
LINK
POWER
DR-8SW16A
CHANNEL 16A RELAY SWITCH MODULE
8
LINK
POWER
DR-PS1000
POWER SUPPLY MODULE
POWER
Wifi Router
Keypad Electrical Box