3-90-05822R 28_08/13
"PREVENT HOUSE FIRES"
Install and Use Only in Accordance With Manufacturer's Installation and Operation Instructions.
Contact Local Building or Fire Offi cials About Restrictions and Installation Inspection in Your Area.
WARNING : THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL,
AND CEILING/ROOF MUST BE MAINTAINED. DO NOT INSTALL IN SLEEPING ROOM.
An outside combustion air inlet must be provided. Combustion air should not be obstructed. Refer
to Manufacturer’s instructions and local codes regarding the requirements for passing the exhaust
venting system through a combustible wall or ceiling.
Inspect and Clean Exhaust Venting System Frequently.
Use a 3" or 4" diameter type "L" or "PL" venting system.
Do Not Connect This Unit to a Chimney Flue Serving Another Appliance.
FOR USE WITH WOOD PELLET FUEL OR UP TO 50% CORN / PELLET MIXTURE ONLY.
The Use of Other Fuels May Create an Unsafe Condition.
Input Rating Max: 5.5 lb. fuel/hr.
U.S. Electrical Rating: 115 VAC, 60 Hz, Start 4.2 AMPS, Run 2.8 AMPS
Route Power Cord Away From Unit.
DANGER: Risk of Electrical Shock. Disconnect Power Before Servicing Unit.
For Further Instruction, Refer To Owner's Manual.
Replace glass only with 5mm ceramic available from your dealer.
Keep Viewing and Ash Removal Doors Tightly Closed During Operation.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Report #/ Rapport #135-S-22-4, 135-S-22b-6.2
Tested to / Testé à:
ASTM E 1509-04, ULC/ORD-C1482-M1990,
ULC-S627-00
Made in U.S.A. of US and imported parts. / Fabriqué
aux États-Unis-d’Amérique par des pièces d’origine
américaine et pièces importées.
"PREVENTION DES INCENDIES"
Respecter scrupuleusement les instructions du constructeur pour l'installation et les consignes
de fonctionnement. Respecter les règles de sécuritè en vigueur dans votre région.
AVERTISSEMENT POUR MOBILE HOMES: Ne pas installer dans une chambre. ll est imperatif
de prévoir une prise d'alr extérieur. L'intégrité structurale du plancher, du plafond et des murs doit étre
strictement préservée. Se reporter aux instructions du fabricant et aux réglementations spécifi ques
locales concernant les précautions requises lors de la traversée d'un mur ou d'un plafond.
Contróler et nettoyer fréquemment tout le systeme d'evacuation des fumées conformément aux
recommandations du constructeur. Utiliser des tuyaux <<Spécial granulés>> de Ø76 mm ou
102 mm. Ne pas raccorder ce poéle à un conduit de cheminée déjà utilisé pour un autre appareil.
FONCTIONNE EXCLUSIVEMENT AVEC DES GRANULES DE BOIS.
Appareil de chauffage à granulé type. Consommation maximum: 3.63 kg/h.
US coupure: 115 VAC, 60 Hz, 4.2 amps Démarrer, Exécuter 2.8 AMPS
Tenir le cordon d'alimentation à l'écart du poèle.
DANGER: Risque d'électrocution. Débrancher l'appareil avant toute intervention.
Ne remplacer la vitre qu'avec une vitre céramique 5mm de méme qualité disponible
auprès de votre revendeur.
Pour une information plus compléte, se reporter à la notice d'utilisation. Tenir la porte
hermétiquement close durant fonctionnement.
Ne faites pas obstacle l’espace sous le réchauffeur. Toujours fournir un approvisionnement suffi sant en air frais
jusqu’au lieu d’installation Appliance
MODEL / Modéle: “P61A”
Room Heater Pellet Fuel Burning Type. Suitable for Mobile-Home Installation.
Appareil de chauffage à granulés de bois Conçu pour maisons mobiles
2"(51mm)
12" (305mm) with side shields
18" (457mm) w/out side shields
9”(228mm)
13”(330mm)
9"(228mm)
13”(330mm)
min
7mm min
min
7mm min
BARCODE LABEL
MINIMUM CLEARANCES TO COMBUSTIBLES/
DISTANCES DE SECURITE PAR RAPPORT AUX
MATERIAUX COMBUSTIBLES:
Back Wall / Entre Mur Arrière 2”/ 51mm 2”/ 51mm
Side Wall / Entre Paroi Latér 18”/ 457mm 12”/ 305mm
CORNER INSTALLATION / EN ANGLE
Walls to Appliance 13”/330mm 9”/228mm
Entre Murs et appareil
Flue Connector/Raccord à la cheminée 3” /76mm
FLOOR PROTECTION / Protection Du Plancher
USA Canada
Sides*/Côtés (A) 6” 200mm
Back**/Arrière (B) 6” 200mm
Front*/Avant (C) 6” 450mm
**Measured from pedestal base in the US ONLY
**Mesuré à partir de la base du socle aux États-Unis uniquement
*Measured from Glass Opening
*Mesurer à partir de la surface de la porte en verre
Floor Protection Must Be a Non-Combustible Material.
Must Also be Place Under Any Horizontal Flue Connector,
Extending 2” or 51mm Beyond the Pipe Measurement.
Pour protéger le plancher, il faut sous le pêole un matériau. Qui
doit aussi être placé sous les parties horizontales du tuyau de
raccord à la cheminée et s’étendre à 51mm o 2 po. au-delà de
la mesure du tuyau.
WITHOUT
SIDE SHIELDS
WITH
SIDE SHIELDS
Sans Écrans
Latéraux
Avec Écrans
Latéraux
US ENVIRONMENTAL PROTECTION AGENCY
This model is exempt from EPA certifi cation under 40 CFR 60.531
by defi nition [Wood Heater (A) "Air-to-Fuel Ratio"]
Agence Américaine pour la Protection de l’Environnement
Ce modéle est dispensé par EPA certifi cation d’aprés 40 CFR 60.531
par dèfi nition [Appareil á bois (A) << Ratio air/combustible>>]
Harman P1A Pellet Stove
Black Background with bare metal for print-adhesive backed, metal plate.
AA C
B
USA CANADA
Floor protector
PR OTECTION DE SOL
F LOOR PR OTECTION
008
Serial No.
No de série:
R ev DP.N. 3 -9 0 -0 8 6 2 6
Date of Manufacture / Date de fabrication:
2 0 1 3 2 0 1 4 2 0 1 5 J AN F EB MAR APR MAY J UN J UL AUG SEP OCT NOV DEC
Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032
2
P1A Pellet Stove
The Label Pictured Is For Reference Only. For specic infor-
mation regarding testing and clearances, consult the actual
label on the rear of the stove.
Please copy
your serial
number from the label
on your stove to the box below.
SER IAL NUMBER