Hartmann Altronix T1HCK3F4D User manual

Access & Power Integration
T1HCK3F
Up to 8 Door Kit
Fully assembled kit includes:
- Trove1 enclosure with
THC1 Altronix/Hartmann Controls backplane
- One (1) eFlow6NB - Power Supply/Charger
T1HCK3F4
Up to 8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with
THC1 Altronix/Hartmann Controls backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) ACM4 - Fused Access Power Controller
T1HCK3F4D
Up to 8 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with
THC1 Altronix/Hartmann Controls backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) ACM4CB - PTC Access Power Controller
Altronix/Hartmann Controls Kits
Models Include:
Rev. T1HC082423
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners.
Installation Guide
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

- 2 - THC1 Kits Installation Guide
Overview:
Altronix/Hartmann Controls Trove kits are pre-assembled and consist of Trove enclosure with factory installed Altronix power supply/chargers and
sub-assemblies. Each kit also accommodates one (1) Hartmann Controls PRS_Master boards and up to four (4) PRS_TDM or PRS_IO8 boards.
Configuration Chart:
Altronix
Model Number
120VAC 60Hz Input
Current (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
Nominal DC Output Voltage Options Maximum
Supply Current for
Main and
Aux. Outputs on Power
Supply board and
ACM4 Access Power
Controller’s
outputs (A)
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
Current Per
ACM4(CB) Output (A)
ACM4(CB) Board
Input Fuse Rating
ACM4(CB) Board Output
Fuse (PTC) Rating
[DC] [AUX]
12VDC
Output
Range
(V)
24VDC
Output
Range
(V)
12VDC
Output
Range
(V)
24VDC
Output
Range
(V)
T1HCK3F 3.5 5A/
250V
15A/
32V
eFlow6NB
12 or 24VDC @ 6A ––––
10.0-
13.2
20.19-
26.4
10.03-
13.2
20.19-
26.4
T1HCK3F4
3.5 5A/
250V
15A/
32V
eFlow6NB 12VDC @ 5.4A
or
24VDC @ 5.7A
4
2.5 10A/
32V
3A/
32V
T1HCK3F4D 10.0-
13.2
20.19-
26.4
10.03-
13.2
20.19-
26.4 2.0 10A/
32V 2.5A
Hardware and Accessories:
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install
the three fasteners. Place the enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location,
opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the
right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the
appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Hartmann Controls boards to backplane, refer to pages 3-4.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB and
Sub-Assembly Installation Guide for ACM4(CB) for further installation instructions.
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Nylon or Metal Spacer | 5/16” Pan Head Screw | Lock Nut

THC1 Kits Installation Guide - 3 -
T1HCK3F: Configuration of Hartmann Controls Boards:
1. Align the Hartmann Controls boards on the backplane to match the boards’ mounting holes with corresponding pems.
2. Fasten spacers (provided) to pems that match the hole pattern for Hartmann Control boards (Fig. 2, 2a, pg. 3).
Note: Hartmann Controls boards must be properly grounded.
Please use provided metal spacers for the lower right mounting holes (Fig. 2, pg. 3).
3. Mount Hartmann Controls boards to spacers utilizing provided 5/16” pan head screws (Fig. 2a, pg. 3).
4. Fasten backplane to Trove1 enclosure utilizing lock nuts (provided).
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGER
AC DCAC1
EOLNOGND
SUPERVISED RESET
+AUX-
- BAT +-DC +
L G N
OFF - 24V
ON - 12V
ON
Altronix eFlow6NB
PRS_MASTER
Metal Spacer
Metal Spacer Metal Spacer
PRS_TDM or PRS_IO8 PRS_TDM or PRS_IO8
PRS_TDM or PRS_IO8 PRS_TDM or PRS_IO8
Metal Spacer Metal Spacer
Pem
Spacer
Hartmann Controls
Board
Backplane
Pan Head
Screw
Fig. 2a
Fig. 2 - T1HCK3F Congurations

- 4 - THC1 Kits Installation Guide
T1HCK3F4(D): Configuration of Hartmann Controls Boards:
1. Align the Hartmann Controls boards on the backplane to match the boards’ mounting holes with corresponding pems.
2. Fasten spacers (provided) to pems that match the hole pattern for Hartmann Control boards (Fig. 3, 3a, pg. 4).
Note: Hartmann Controls boards must be properly grounded.
Please use provided metal spacers for the lower right mounting holes (Fig. 3, pg. 4).
3. Mount Hartmann Controls boards to spacers utilizing provided 5/16” pan head screws (Fig. 3a, pg. 4).
4. Fasten backplane to Trove1 enclosure utilizing lock nuts (provided).
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGER
AC DCAC1
EOLNOGND
SUPERVISED RESET
+AUX-
- BAT +-DC +
L G N
OFF - 24V
ON - 12V
ON
Altronix eFlow6NB
PRS_MASTER
Metal Spacer
Metal Spacer Metal Spacer
PRS_TDM or PRS_IO8 PRS_TDM or PRS_IO8
PRS_TDM or PRS_IO8 PRS_TDM or PRS_IO8
Metal Spacer Metal Spacer
TRG
TRIGGER
INPUT
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix
ACM4(CB)
Pem
Spacer
Hartmann Controls
Board
Backplane
Pan Head
Screw
Fig. 3a
Fig. 3 - T1HCK3F4 Congurations

THC1 Kits Installation Guide - 5 -
Notes:

- 6 - THC1 Kits Installation Guide
Notes:

THC1 Kits Installation Guide - 7 -
eFlow Power Supply/Chargers can be Controlled and Monitored while
Reporting Power/Diagnostics from Anywhere over the Network...
LINQ2 Mounts Inside any Trove Enclosure
LINQ2 - Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help
keep systems up and running at optimal levels. It facilitates fast and easy installation and set-up,
minimizes system downtime, and eliminates unnecessary service calls, which helps reduce Total
Cost of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR).
LINQ2
Features:
- UL Listed in the U.S. and Canada.
- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change,
output state change and unit temperature.
- Accesscontrolandusermanagment:Restrictread/write,Restrictuserstospecicresources
- Two (2) integral network controlled Form “C” Relays.
- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
- EmailandWindowsDashboardnotications
- Event log tracks history.
- Secure Socket Layer (SSL).
- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.
LINQ2 Module
Altronix eFlow
Power Supply
Network Connection:
Installation, Programming
and Monitoring

- 8 - THC1 Kits Installation Guide
Enclosure Dimensions (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)
4.5” (114.3mm) 4.5” (114.3mm) 2.75”
(69.9mm)
1.115” (28.3mm)
1.36” (34.5mm)
1.25” (31.8mm) 1.25” (31.8mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
4.5” (114.3mm)
13.0” (330.2mm)
0.6” (15.2mm)
14.5” (321.3mm)
1.45” (36.8mm)
7.25” (184.2mm)
1.95” (49.5mm)
1.1” (27.9mm)
0.6” (15.2mm)
0.57” (14.5mm)
18.0” (457.2mm)
1.25” (31.8mm)
Hartmann Controls is not responsible for any typographical errors.
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
10 Lockhart Rd, Barrie, ON L4N 9G8, Canada | phone: 1-877-411-0101
IITHC1 Kit Series H24W
This manual suits for next models
2
Table of contents
Popular Control System manuals by other brands

Siemens
Siemens SIMATIC PC BI45 Technical description

Whelen Engineering Company
Whelen Engineering Company CanTrol Installation & operating guide

CNC Router Parts
CNC Router Parts CRP4896 Assembly instructions

Sutter
Sutter Lambda VF-5 Operation manual

ERS
ERS AK 6000 user manual

INIM
INIM PREVIDIA MAX installation manual

Calimet
Calimet CM9-2 Installation and owner's manual

BriskHeat
BriskHeat LYNX instruction manual

Sutter Instrument
Sutter Instrument Lambda SC USB Installation & Configuration

Contrive
Contrive FIRO manual

Siemens
Siemens SIMATIC HMI ITC1500 V3 PRO Quick install guide

herdstar
herdstar BinTrac BTB-200 Operation manual