HATHASPACE HSD001 User manual

Dehumidifier
Model HSD001


Specificaons 1
Product Overview 1
Product Diagram 2
Features 3
Operaon 4
Maintenance 4
Precauons 5
5
Troubleshoong
CONTENTS

1
Product Model HSD001
8 x 5.5 x 14 inches
4.4 lbs (2 kg)
AC 120V 60Hz
40 W
2L (68 oz)
750ml/day (86°F, 80% RH)
41 – 122°F (5 – 50°C)
300 sq (28 sq m)
Product size
Weight
Power Input
Power Consumpon
Water Tank Capacity
Working Capacity
Working Temperature
Range
Coverage Area
SPECIFICATIONS
PRODUCT OVERVIEW
The Hathaspace Dehumidifier removes 750ml of moisture from your air every
24 hours, creang an opmal air environment. Being a Peler (thermo-electric)
dehumidifier, the Hathaspace HSD001 funcons by pulling in warm humid air
and running it across the front of a cold heat sink. As the air passes over the
cold surface, it condenses and the moisture is deposited into the reservoir,
while the dry air is recirculated back into the room. Unlike tradional
compressor or desiccant dehumidifiers, the HSD001 is portable, lightweight,
whisper-quiet, and energy efficient – making it ideal for removing unwanted
moisture in most small to mid-size rooms (up to 300 sq. .).

PRODUCT DIAGRAM
2
Reservoir
Floater Cover Buckle
Water Level
Window
Drain Plug/
Hose Fing
Reservoir
Handle
Indicator
Power Cord
Power Buon
Air Outlet
Air Inlet
Rubber Feet
Filter Handle
Pre-filter
Filter Handle
Pre-filter

3
FEATURES
The pre-filter captures any large parcles in the air before dehumidificaon,
preserving the life of your dehumidifier. Simultaneously, it helps to keep
your air even cleaner.
Pre-Filter
Automac shut-off iniates when the water reservoir is full or when the
reservoir is removed. When the reservoir is full or when the reservoir is
pulled out, the indicator will turn yellow, leng you know it’s me to
empty it.
Auto Shut-Off
The Hathaspace HSD001 has two modes: Sleep and High. Sleep mode
operates at a whisper-quiet level of 35 decibels. High mode maximizes
the dehumidificaon for when you need it most.
Two Operaon Modes
If you don’t want to worry about emptying the reservoir, simply connect
the included hose and put the other end somewhere where the water
could be drained or used (like a plant pot). Keep it running all of the me
without having to worry about checking in. Just make sure whatever it
leads to is large enough to cover the me you are away between check ins.
Connuous Drainage
Designed to work in temperatures ranging from 41 – 122°F (5 – 50°C),
the dehumidifier has an auto-defrost funcon, allowing for efficient
operaon in cold temperatures, where other dehumidifiers can’t.
Auto-Defrost Funcon

OPERATION
4
• Press Power once to enter Sleep mode.
• Press Power twice to enter High mode.
• Press Power a third me to turn off the unit.
Basic Operaon
MAINTENANCE
• Power off the unit and unplug prior to maintenance.
• Wipe the air inlet side of the dehumidifier with a damp towel to remove
parculate buildup.
• Clean the pre-filter every 2 months of operaon by running under water
and/or using a so compressed air can.
• Leaving water in the reservoir for extended periods of me will result in a
buildup of mold, as with any sll water. Empty the reservoir and clean it
regularly.
• Do not use any abrasive, corrosive, or flammable cleaners (such as bleach
or alcohol) to clean any part of the machine.
• Do not drop any water into the machine when cleaning.
• Use a so toothbrush or cloth to remove any mold buildup.
• Completely wipe dry the reservoir with a paper towel frequently.
Cleaning the Reservoir
• When full, the reservoir indicator will turn yellow, and the unit will stop
running to keep from overflowing.
• Power off and unplug the unit before emptying.
• Carefully remove the water reservoir.
• Press in on the cover buckles and remove the cover.
• Pour out water.
• Secure the cover buckles onto the reservoir.
• Reinstall the reservoir by aligning the grooves in the unit with those in
the unit.
• Plug the unit back into the wall outlet.
• Slide the reservoir into the unit fully unl secured. The unit’s light indicator
will suggest it is installed properly if it turns back on.
Pouring Out Water

5
PRECAUTIONS
TROUBLESHOOTING
• To avoid electric shock and fire, do not allow water, liquid or any
flammable detergent to enter the internal structure of dehumidifier.
• Do not spray perfume or other flammable sprays around the dehumidifier.
Situaon Reasons for the issue
Unit is not plugged in.
Reservoir is full.
Pre-filter is full of debris.
Use in proper temperature range.
Humidity is not high enough to draw moisture.
Debris stuck in fan our air outlet – use compressed air
can to clean.
Machine is not on a flat surface.
Not working
Poor dehumidificaon/
Not collecng water
Noise from unit
Danger
Safety Warning
• Do not block the inlet and outlet, do not place objects on or in front of the
outlet. Leave at least 30cm of space on the back and sides of the product, and at
least 50cm of space above the product when using.
• This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilies, or lack of experience and knowl-
edge, unless they have been given supervision or instrucon concerning use of the
appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• Before connecng the power supply, please check whether the voltage of the
product is consistent with the local power supply voltage.
• If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
• Ensure that no foreign substances or liquids enter the product through
the air inlet.

Table of contents