manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HAWK ENTERPRISES
  6. •
  7. Fan
  8. •
  9. HAWK ENTERPRISES BPB25A Axial User manual

HAWK ENTERPRISES BPB25A Axial User manual

3320 Axial CFM Air Mover
Dry Floors, Circulate and Exhaust Air
Hawk BPB25A Axial User’s Manual
Hawk BPB25A Axial User’s Manual
HAWK HAWK
ENTERPRISES ENTERPRISES
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
Hawk Limited Warranty
Hawk Enterprises Inc. equipment has been manufactured, tested and inspected with carefully
engineered requirements. Hawk warrants each new machine, part and accessory to be free of
defects in materials and workmanship for a me specified in the table below. Repair or replacement
of defecve parts or service must be conducted by a Hawk authorized service provider.
Warranty Start Date: Warranty coverage starts on the date the machine is installed at the end user's
site, or six months from the ship date from the factory, whichever comes first. The distributor who
sold you the machine is responsible for compleng the registraon form at
www. hawkenterprises.com/service_registraon. This forms idenfies the machine and records
warranty state date.
Warranty Coverage - Hawk Air Movers
Motor and Gearbox - 1 year
Non-Wear Items - 6 months
Repair Parts - 90 days
Service Labor - 6 months
Excepons and Exclusions from the Limited Warranty
This warranty does not cover repairs resulng from accident, abuse, misuse, damage in transit, or
lack of proper maintenance. Equipment must be used with electric current noted on the data plate.
Damages from operaon at other voltages or currents will void the warranty.
Certain normal wear parts are consumed in use of this machine, and are not covered by this
warranty. These parts include, but are not limited too, cords, switches, bumpers, bearings, isolators,
carbon motor brushes, compensators, brushes, pad drivers, bulbs, bags, v-belts and filters. No other
warranes extend beyond the terms of this Hawk Limited Warranty, including implied warranty of
merchantability or fitness of this machine for a parcular use.
How to Set Up Warranty Repair
Equipment must be repaired by a Hawk approved service provider; the dealer who sold the new
equipment or any Hawk distributor service department in the US. Repairs or alteraons made by
anyone other than the Hawk factory or a cerfied repair staon, will void the warranty.
The distributor who sold you the machine is responsible for registraon of the machine with the
factory. With this registraon, Hawk will have all of the records required for warranty claim,
including records of ownership, date of delivery and resulng warranty dates and terms,
distributor's locaon, machine model, type and serial number. To find the closest service provider,
contact Hawk Customer Service at 1-574-294-1910 or customerservice@hawkenterprises.com.
Warranty claims must be submied within 30 days of service request.
Replacement
In the event of a malfuncon resulng in a warranty claim, Hawk, may at its sole opon, replace the
equipment or warranted part with another new part of equal quality instead of repairing that part.
No Refund of Purchase Price
Hawk will not, as a maer of this warranty agreement, refund the end user's purchase price.
13.0”
20.0”
The Chassis is
Rotomolded with a
Profile for Stacking
and Convenient
Storage
Add the Folding
Metal Frame to
Direct Air at Every
Angle
GFCI Shock-
Prevenng Outlets
Make Daisy Chain
Connecon Easy
(2) GFCI Outlets and
Convenient 2-Speed
Switch
Specificaons
Model BPB25A Axial
Motor 1/4 HP, 2-Speed, 115V, 60 Hz, Sealed Motor
Amp Draw 2.6 Amp (High Speed), 1.3 Amp (Low Speed)
Air Volume 3320 CFM Max
Air Flow Direcon 0 degrees
Hour Meter Yes
LED Power Indicator Yes
Chassis Construcon Sturdy Rotomolded Plasc
Stackable 5 units
Daisy Chain Yes - Up to 5 Units
Weight 30 lbs. (net) / 34 lbs. (gross)
Size (L x W x H) 22.5” x 13” x 20”
Aached Cord 25 Ft. 14 AWG
Sound Level 78 dB
Cerficaon C-ETL-US
The Hawk BPB25A Axial with 1/4 HP 2-
speed sealed motor with attached 25
ft. AWG power cord moves air
efficiently with less power. The unit
moves up to 3320 CFM air in a 50 ft.
beam of air. Daisy chain in-line connect
up to 5 units for focused airflow A
built-in GFCI Auxillary Outlet* reduces
risk of electric shock in wet areas.
*Required for use when Insurance Companies
are paying for water and flood cleanup claims
Unpacking & Checking Of Contents
Unpack your BPB25A Axial carefully and inspect if all parts are intact. If any of the parts
are missing damaged, please contact Hawk Customer Service at (574) 294-1910 or e-mail
to customer-service@hawkenterprises.com.
Operang Instrucons
This BPB25A requires NO ASSEMBLY. The unit is packaged and ready to be put to work.
The unit is intended to be used for drying carpet spills, drying surfaces such as bathroom
floors, venlang as well as circulang air.
1. Place the unit on the surface that needs to be dried.
2. Plug the unit into a grounded outlet .
3. Select the desired speed and posion
Floors and Carpet Maintenance
WARNING: As with all electrical equipment, the unit must be
disconnected from power before servicing or cleaning.
ŸBefore each use, inspect the unit for damage, blocked inlets and exhaust and for
foreign material buildup.
ŸWhen the air mover is turned on, inspect the unit for excessive vibraon. In the event
of excessive vibraon or if the fan wheel rubs against the rotomolded housing,
immediately turn off the unit and have a cerfied technician inspect the unit.
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
ATTENTION!
Read all safety rules carefully before aempng to operate the
BVP25D. Please retain this manual for future reference.
NEVER operate this unit when flammable materials or vapors
are present -- electrical devices produce arcs or sparks which
may cause a fire or an explosion.
NEVER operate this unit unaended.
WARNING!
To reduce the risk of fire, electric shock or injury, follow the
direcons below:
ŸDo not use an extension cord with this air
mover.
ŸDo not use with solid state speed control
device.
ŸDo not allow to be used as a toy. Close
aenon is necessary when used by or near
children.
ŸDo not unplug by pulling on cord. To unplug,
grasp the plug, not the cord.
ŸDo not use with damaged cord, plug or
other parts.
ŸCall customer service if your air mover is not
working as it should, has missing parts, has
been dropped, damaged, le outdoors or
dropped into water.
ŸDo not pull or carry by cord, use cord as
handle, close a door on cord, or pull cord
around sharp edges or corners. Keep cord
away from heated surfaces.
ŸDo not run cord under carpeng. Do not
cover cord with throw rugs, runners or
ŸUse product only as described in this
manual.
ŸTo reduce the risk of electric shock, do not
expose to rain, immerse in or use in standing
water. Store indoors only.
ŸUse only with GFCI-protected outlets.
ŸWhen storing or transporng, do not stack
air movers more than 5 units high.
ŸElectrical appliances can ignite flammable
vapors or dust. Do not use near combusble
liquids, gases or dusts.
ŸDo not leave plugged into outlet when not in
use or when servicing. Turn off before
unplugging.
ŸTo reduce the risk of srring up and inhaling
toxic vapors, do not use near toxic or
hazardous materials.
ŸNever operate with safety grills removed.
ŸThis unit has an automacally-operated
protecve device which may shut down the
unit during operaon. Unplug before
servicing or cleaning.
WARNING!
ŸTo reduce the risk of electric shock, connect only to a GFCI
protected outlet. Do not expose to water
CAUTION
ŸThis air mover has an automac motor shutoff device. It
may restart without noce.
ŸTo reduce the risk of injury, unplug before servicing.
WARNING!
ŸDo not use an extension cord with this fan. To reduce the
risk of p-over during storage or transport, stack up to 5
units high only.
32
HAWK HAWK
ENTERPRISES ENTERPRISES Hawk BPB25A Axial User’s Manual
Hawk BPB25A Axial User’s Manual
Oponal Folding Metal Frame
The rotomolded chassis if built with mounng lug
nuts for mounng of the folding metal frame.
The frame lets you direct the airflow in every
direcon.
Motor Specificaons & Electrical Requirements
This BVP25D has a 1/4 HP, 3-speed, 115-volt, 60 Hz inducon motor with a grounding
conductor. Thermally protected, it will automacally shut down if overheated. The motor
will restart automacally once cooled, for as long as it is plugged into a power source.
In the event of a malfuncon or breakdown, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock.
This air mover is equipped with an 10 . 14 AWG electric power cord having an equipment
grounding conductor and a grounding plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in accordance with all local codes and
ordinances. Do not modify the plug provided. If it will not fit the outlet, have the proper
outlet installed by a qualified electrician.
Power Cords
ŸUse three-pronged adapters that are UL and CE approved and with Ground Fault
Circuit Interrupter (G.F.C.I.).
ŸDo not use cords that show any kind of wear or damage.
ŸCords are not covered by warranty
WARNING! The Total amperage of the BVP25D Air Mover plus all other
devices plugged into the receptacle must not exceed 12 amps.
Grounding Instrucons
The BVP25D must be grounded. Should it malfuncon, grounding provides a path of least
resistance for electric current and reduces the risk of electric shock. This appliance is
equipped with a cord that has an equipment-grounding conductor and a grounding plug.
The plug must be inserted into a properly installed and grounded outlet, in accordance
with all local
WARNING!
Improper
connecon of the
equipment-
grounding
conductor can
result in the risk of
an electric shock.
Check with a qualified electrician or service person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the plug provided with the appliance. If plug
does not fit the outlet, have a proper outlet installed by a qualified electrician.
NOTE: In Canada, the use of a temporary adapter is not permied by the Canadian
Electrical Code
Use with 115V
3-Prong Grounded
Connection
DO NOT
Use with a 3-Prong to
2-Prong Adapter
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com 54
Lubricaon
NO LUBRICATION IS NECESSARY. The motor is equipped with lifeme lubricated bearings.
Storage & Transportaon
1. Before storing your air mover, it should be cleaned.
2. Wrap the power cord around the carry handle on top of the unit to keep it untangled.
3. If you have more than one unit, store units by stacking. Do not stack more than 5 units
high.
4. Never operate unit while on its side or while stacked.
5. THE BVP50 SHOULD BE STORED INDOORS.
CAUTION:
Do not operate this air mover stacked on top of each other. Do not stack
more than 5 units high for storage.
Servicing
In order to receive service or replacement parts under warranty, you must:
1. Call (574) 294-1910 for an RMA (Return Merchandise Authorizaon Number)
2. Have your proof of purchase ready.
Upon inspecon, we will advise you of the repairs needed and the cost (if applicable).
Hawk will issue repair or replacement parts depending on warranty.
GFCI Protecon and the On-Board Duplex Outlet
The standard AC GFCI outlet on the unit promotes operator safety in wet applicaon. The
GFCI switch trips when electrical ground is sensed. Check the GFCI protecon prior to
operaon by plugging the unit into a 110V outlet. Pushi the “TEST” buon on the control
panel. The buon will pop out. If operang properly, the “RESET” buon on the control
panel will also pop out. Reset by pushing in the “RESET” buon. The unit can be reset
only when the unit is plugged in.
Cleaning
WARNING: To reduce the risk of injury from the air mover accidentally
starng, unplug power cord before cleaning. The outside of the unit may be
cleaned with a damp cloth to remove any dust or residue.
User Servicing Instrucons
WARNING: Be sure to disconnect power supply before aempng to
service or remove any components. Do not aempt to service your air
mover beyond what is described in the user manual. For all other servicing,
follow instrucons in the Warranty secon.
HAWK HAWK
ENTERPRISES ENTERPRISES Hawk BPB25A Axial User’s Manual
Hawk BPB25A Axial User’s Manual
Pro b lem
Possib le C a u se
Solutio n
U n it N o t Run n in g
Sw itch is o ff
Turn o n
N o pow er
Plug unit in ; check circu it b reaker
Bad ou tle t
Check o u tlet, ch an ge to a d ifferen t
outle t
Faulty Switch
Replace sw itc h *
Faulty or b roken m oto r
w ire or cord
U se vo lt/am p m e ter to ch e ck
contin u ity. R e p la ce m oto r w ire o r
cord *
U n it ru n s bu t m akes
loud , g rating noise s
Sev e re jolting ca u se s
blow er w h eel to ru b
again st h o use
Rem o ve and re p la c e d am a ged m o to r
or m oto r m o unts* if n e ed ed
Sev e re jolting defo rm ed
hou sin g
Replace b lo w er w h e e l o r dam aged
hou sin g*
Excessive vibra tio n
Sev e re jolting ca u se d
m o tor shaft to bend –
un it is out o f b alance
Rem o ve and re p la c e m o tor*
D a m a ged b lo w e r w h eel
blade
Rem o ver b lo w er w h e el*
Build-up of dirt on on e
sid e o f b low er w h eel
Clean blow er w h e e l b la d e s
Blow er w h e el n ot
tu rning
Blow er w h e el jam m ed
again st h o usin g
Rem o ve and re p la c e d am a ged m o to r
m o u n ts* R e p la ce blow er w h eel if
needed*
Bro k en /loose cap acitor
w h eel; failed capacitor
Replace capacitor w ire/m oto r if
needed*
D a m a ged h o u sing is
pre ssin g o n blow er
w h eel
Replace h o usin g /u n it, if n eed ed *
U n it ru n s bu t shuts off
on o verlo ad
Failin g m o to r bearing s.
Internal ele ctrical fault
in m o tor
Replace m o to r*
O b stru ctio n in inta ke
grill or e xhaust grill
Rem o ve ob structio n
rotomolded
chassis
switch cover switch &
meter
25’ powercord
cord
connectors
fan
motor
air
intake
grill
air exhaust grill
rubber
feet
76
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK ENTERPRISES - 2902 Park Six Court, Elkhart, IN 46514
(574) 294-1910 - www.hawkenterprises.com
HAWK HAWK
ENTERPRISES ENTERPRISES
Troubleshooting
Construction & Parts
Operator Panel Features
Hawk BPB25A Axial User’s Manual
Hawk BPB25A Axial User’s Manual
Power Indicator Light
Reseable Circuit Breaker
GFCI Plug Outlet
Run-Time Hour Meter
Run-Time Hour Meter displays cumulave operang hours for me tracking.
Hour meter is not reseable and cannot be erased.
Reseable Circuit Breaker protects the unit and connected daisy chained units. It
senses total current drawn. When more than 12 amps are drawn through the power
cord, the breaker trips.
GFCI Ground Fault Circuit Interrupter trips when a fault to electrical ground is sensed,
promong protecon of the operator. A tripped GFCI can be reset when the unit is
plugged into the 110V outlet.
Warning! The total amperage of the unit plus all other devices plugged into the GFCI
outlet must not exceed 12 amps.
2-Speed Toggle
Power Switch
Damaged fan blade
Dirt buildup on one of the
fan blades
Remove and replace fan blade
Clean fan blades
Fan blades not turning Fan blades are blocked Clean blades. Remove obstrucons.
Motor failed Replace motor

Other HAWK ENTERPRISES Fan manuals

HAWK ENTERPRISES BPB25DA Axial User manual

HAWK ENTERPRISES

HAWK ENTERPRISES BPB25DA Axial User manual

HAWK ENTERPRISES BVP50 User manual

HAWK ENTERPRISES

HAWK ENTERPRISES BVP50 User manual

Popular Fan manuals by other brands

Monte Carlo Fan Company Centro Max 5CQM52-L Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company Centro Max 5CQM52-L Series Owner's guide and installation manual

Sunforce 81300 manual 

Sunforce

Sunforce 81300 manual 

Hunter 21587 Manual de Installatión y Operatión

Hunter

Hunter 21587 Manual de Installatión y Operatión

TEFAL Harmony VF3645T0 manual

TEFAL

TEFAL Harmony VF3645T0 manual

Vents KKSA user manual

Vents

Vents KKSA user manual

Mitsubishi Electric LGH-100RX3-CAN Technical manual

Mitsubishi Electric

Mitsubishi Electric LGH-100RX3-CAN Technical manual

Modern Fan Co Velo DC VEL Series Installation instructions and owner's manual

Modern Fan Co

Modern Fan Co Velo DC VEL Series Installation instructions and owner's manual

Patron FA-8 product manual

Patron

Patron FA-8 product manual

Campomatic SF300R operating instructions

Campomatic

Campomatic SF300R operating instructions

Ohyama woozoo PCF-MKM18 user manual

Ohyama

Ohyama woozoo PCF-MKM18 user manual

Faro Barcelona Easy manual

Faro Barcelona

Faro Barcelona Easy manual

Home Decorators Collection INTERVALE N609A-BN Use and care guide

Home Decorators Collection

Home Decorators Collection INTERVALE N609A-BN Use and care guide

Harbor Breeze Bath Ventilator with Light installation guide

Harbor Breeze

Harbor Breeze Bath Ventilator with Light installation guide

Broan EZ80C installation guide

Broan

Broan EZ80C installation guide

Loren Cook LXUL Installation, operation and maintenance manual

Loren Cook

Loren Cook LXUL Installation, operation and maintenance manual

Manta MTF410 instruction manual

Manta

Manta MTF410 instruction manual

aireRyder F0028 manual

aireRyder

aireRyder F0028 manual

Bard ERV-FA2 installation instructions

Bard

Bard ERV-FA2 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.