Diagnostic Codes:
Blower vacuum switch closed
Blower vacuum switch open (check voltage selector plug on new install)
Bad board or secondary high voltage fault
Communication error between control module and display
interface assembly
Bad board
Flame present with gas valve not energized
Maximum return water temp exceeded and/or rapid water
temp rise
Ignition failure
Igniter circuit open
Water pressure switch, vent pressure switch or temp limit switch
Voltage polarity reversed, low voltage detected
Keypad failure (stuck button)
Temp sensor (thermistor input failure)
Hold
AC -
AO -
bd -
CE -
EE -
HF -
HS -
IF -
IO -
LO -
PF -
Sb -
SF -
‘bo’ (bypass operation -2 wire ONLY)
Press to place the heater in
MODE
MODE
&
STANDBY
SPA
POOL
SERVICE
HEAT
TEMP SET MODE
Max Pool Temp Limit is Pre-set To Energy-saving 90 F, See Owner’s Manual.
‘STANDBY’ Mode.
for 3 seconds
for ‘bo’ to appear. Heater must be in Spa or Pool Mode
for bypass operation to work
Temperature Lockout
Hold the
Press to place heater in ‘STANDBY’ Mode.
MODE
& for 3 seconds.
SPA LED indicates max temp for Spa; use arrows
Press , POOL LED indicates max temp for
MODE
Press again to return to STANDBY.
MODE
to adjust max temp.
Pool; follow above sequence.