InformationMenu
TheInformationMenudisplaysvaluablesystemandpoolinformation.TheAquaRiteProwill
defaulttodisplayingaportionoftheInformationMenuwhennobuttonshavebeenpushedfor2
minutes.Theunitwillautomaticallyscrollthroughseveralstatusdisplays.Toaccessallofthe
InformationMenuitems,pushtheINFObuttononthefrontpanel.Advancethroughthevarious
menuitemsusingthe"<"or">"buttons.AlistoftheInformationMenuitemsisshownbelow.
TheAquaRiteProdesiredoutput%isshownhere.IfSuperChlorinateisactive,the
displaywillshowthetimeremaininguntiltheAquaRiteProwillreturntothedesired
output%.ThismenuisdisabledifanAQL-CHEMisusedandORPAutoSensingis
enabled(seeAQL-CHEMmanual).
Thisdisplaywillbeshownonlyifchemicalsensingisenabled.Thisdisplayshowsboth
pHandORPlevels/statuswhenchemistrysensingisenabledviatheChemistryCon-
gurationWizard(requirestheuseofAQL-CHEMSensingKit).TheAquaRiteProwill
refertotheselevelstodeterminehowmuchchlorinetogenerate(ORP)andhowmuch
CO2oracidtodispense(pH).RefertotheAQL-CHEMmanualforspecicinformation
abouttheselevelsaswellastherecommendedranges.
+/-23.45Visthevoltageappliedtothechlorinatorcell
+/-6.75Aisthecurrent(amps)throughthecell
84ºFisthewatertemperatureatthecell
3200PPMisthe“instant”saltlevelatthistime
Forthechlorinatortobeoperating,severalconditionsmustexist:thelterpumpmust
berunning,theowswitchmustbedetectingow,thechlorinatorsettingmustbeset
greaterthan0%,thewatertemperatureatthecellmustbebetween50ºFand140ºF,
andthesaltlevelmustbewithintheoperatingrange.Ifanyoftheseconditionsare
notmet,thechlorinatordiagnosticdisplaywilltellyouthereason.It’spossibletohave
morethanonereason,inwhichcaseafteryourectifywhatwasdisplayedthersttime,
aseconddisplaywillappear.
Ifthecurrent(amps)displayis0.00A,thenthechlorinatorisoperatingnormallybutis
intheoffpartofitsnormaloperatingcycle.Simplypresseitherthe“+”or“-“keyto
startanewcycle.
TheAquaRiteProperiodicallyreversesthepolarityofthevoltageappliedtothecell
inordertoautomaticallycleanoffanycalciumdepositsthatmayhavebuiltuponthe
cell.Itisimportantthatyoucheckthechlorinatoroperationinbothpolarities.Todo
this,presseitherthe“+”or“-“buttonsandthechlorinatorwillturnoff,waitfor15
secondsandthenturnonintheoppositepolarity.
Chlorinator
50%
No function
Move to previous/next menu item
Super Chlorinate
22:15 remaining
No function
Move to previous/next menu item
if ORP Auto Sensing is not used
pH 7.5 (On)
ORP 700 mV (On)
No function
Move to previous/next menu item
if AQL-CHEM is used
Set Day and Time
Wednesday 10:37P Move to previous/next menu item
+23.45 +6.75A
84°F 3200PPM
Press to switch chlorinator operation to opposite polarity (15 second delay)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS