Assembly Instructions M8110-EN
1. Proceed as follows in order to cool down the unit and empty
the mould (mould evacuation)
Display menu page Functions.
Select the function Cooling and activate with the key.
Select the function Mould evacuation and activate with the
key.
The activated function is indicated with the symbol.
2. Main switch off, remove the plug from the mains and empty
the unit.
3. Remove the cover from the unit (see Instruction Manual
Chapter Maintenance).
4. Proceed as follows in order to remove the cooling
valve 2 (M 4):
Loosen the screw fixing the multiphase motor on the
proportional module (2.1).
Turn the multiphase motor, slightly extract and move out of
connection.
Remove the Torx locking screw for fixing the guide bush.
Disconnect the modules of the proportional module (2.1) from
each other using 2x hexagon head screws.
Remove piston and guide sleeve.
ATTENTION!
Damage due to wrong mounting
An incorrect assembly can lead to malfunctions.
Therefore:
–Observe correct mounting.
–Handle all parts with care.