Assembly Instructions M8125-EN
1. Proceed as follows in order to cool down the unit and empty
the mould (mould evacuation)
Display menu page Functions.
Select the function Cooling and activate with the key.
Select the function Mould evacuation and activate with the
key.
The activated function is indicated with the symbol.
2. Main switch off, remove the plug from the mains and empty
the unit.
3. Proceed as follows to replace the sound transducer (BB 1.x,
BB 2.x) at measuring ciricuit x:
Fig. 1: Flow-5, autonom. module
Fig. 2: Connection of sound transducer
(BB 1.x, BB 2.x) to 8 pin cable plug.
Disconnect the cable plug from the socket (X 402.x)Fig. 1) at
the evaluation unit.
Disassemble screws (Label 1 Fig. 1) and remove cover.
Disconnect sound transducer (BB 1.x, BB 2.x Fig. 1) .
Open the 8 pin cable plug and replace the sound transducer
(BB 1.x, BB 2.x) with a new one (connect cable plug Fig. 2).
Close 8 pin cable plug and connect it to the socket (X 402.x
Fig. 1).
Connect new transducer (BB 1.x, BB 2.x Fig. 1) (tighten with
max. 30 Nm torque).
Mount covers with screws (Label 1 Fig. 1).
4. Reconnect mains plug and switch on main switch.
5. Press the key to switch on the unit and check it for leaks.