manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HDL
  6. •
  7. Control Panel
  8. •
  9. HDL HDL-MPT2.46 User manual

HDL HDL-MPT2.46 User manual

This manual suits for next models

2

Other HDL Control Panel manuals

HDL HDL-MP8B-RF.18 User manual

HDL

HDL HDL-MP8B-RF.18 User manual

HDL Granite Display User manual

HDL

HDL Granite Display User manual

Popular Control Panel manuals by other brands

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

STG-BEIKIRCH MZ3 operation instruction

STG-BEIKIRCH

STG-BEIKIRCH MZ3 operation instruction

Efka Variocontrol V810 instruction manual

Efka

Efka Variocontrol V810 instruction manual

Cebora 208-10 instruction manual

Cebora

Cebora 208-10 instruction manual

AMX AutoPatch CP-15 instruction manual

AMX

AMX AutoPatch CP-15 instruction manual

Satel CA-6 KLED-S user manual

Satel

Satel CA-6 KLED-S user manual

Evolution IQ plus 800 installation manual

Evolution

Evolution IQ plus 800 installation manual

Fagor 8040 TCO CNC operating manual

Fagor

Fagor 8040 TCO CNC operating manual

AKO PROCool AKO-17635-2 quick guide

AKO

AKO PROCool AKO-17635-2 quick guide

ABB 6136/30M-101 operating instructions

ABB

ABB 6136/30M-101 operating instructions

Telikou BK-603 Belt Pack instruction manual

Telikou

Telikou BK-603 Belt Pack instruction manual

Mapei Mapeheat Thermo Touch user guide

Mapei

Mapei Mapeheat Thermo Touch user guide

Bosch D9412GV4 owner's manual

Bosch

Bosch D9412GV4 owner's manual

Mitsubishi Heavy Industries SC-SL4-AE2/1 user manual

Mitsubishi Heavy Industries

Mitsubishi Heavy Industries SC-SL4-AE2/1 user manual

Sminn BOX L VF1L EI instruction manual

Sminn

Sminn BOX L VF1L EI instruction manual

Balboa TP600 user manual

Balboa

Balboa TP600 user manual

Nice HSCU1 Instructions and warnings for installation and use

Nice

Nice HSCU1 Instructions and warnings for installation and use

Truma CP plus installation instructions

Truma

Truma CP plus installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Professional Home and Building Automation Do you need help? Contact with us
support1@hdlchina.com.cn
www.hdlautomation.com 1/ 2
Parameters
Electric Parameters (from HDL-MPPI.46 ):
BUS Power Supply DC12-30V
BUS Power consumption
(from HDL-MPPI.46) 20mA/DC24V
Environmental Conditions:
Working Temperature -5℃~45℃
Working relative Humidity Up to 90%
Storage Temperature -20℃~+60℃
Storage relative Humidity Up to 93%
Approved
CE
RoHS
Production Information:
Dimensions 86×116.5×10.5 (mm)
Weight MPT2.46:137.5(g); MPT4.46: 143(g)
MPT6.46:
Housing material Glass
Installation US wall box
Protection IP20
Overview
■It must work in conjunction with HDL-MPPI.46.
■Real product may be different from pictures on the right.
■Touch performance –touch panel sensitivity need to be read-
justed after installation.
■IR receiver function –only available for customized touch panel
with IR receiving hole.
■The cover can be replaced by the user .
■Bus cable—HDL Buspro/KNX cable, 0.8mm single-core copper
cable.
■Bus Connection—Series connection (hand-in-hand).
■Installation—US wall box.
Important Notes
Installation Step
■Connect bus cables. Make sure the color of wire complies
with the definition
■Make sure the Bus cable type is correct and has no short
circuit
■Mount the HDL-MPPI.46 in the wall-box
■Put this device into HDL-MPPI.46
HDL - MPT2.46
HDL - MPT4.46
HDL - MPT6.46
■Key Mode: Single on/off, Single on, Single off, Combi-
nation on, Combination off, Combination on/off, Short/
long press, Short press/long press..
■Key Control Type: Scene, Sequence, Timer, Universal
Switch, Single Channel Control, Broadcast Scene,
Broadcast Channel, Curtain Control, GPRS Control,
Panel Control, Security Module, Music Play, Universal
Control, etc.
■Built-in IR receiver, need to replace a plate with an IR
receiving hole to enable the IR remote control function.
■IR remote control function.
■Adjustable backlight color and intensity .
■Support HDL Buspro online upgrading .
■Customized image for touch panel.
Functions
HDL Buspro Definition for Cable
HDL Buspro HDL Buspro/KNX
DC24V Red
COM Black
DATA- White
DATA+ Yellow
Multi-function control panel, embedded with RGB
LED backlight for each touch button, any color is
available for the button via setting in HDL Buspro
configuration tools software.
Safety attention
■The screw down strength should not exceed 0.1Nm
■Mounting position: indoor
■Do not make wrong connection on Bus interface, it
will damage the Bus interface of this module
■Never let liquids get into the module, it will damage
this device
■Do not get AC power into Bus wire , it will damage all
devices in the system
■Ensure good ventilation
■Avoid contact with liquids and aggressive gases
HDL-MPT2.46 HDL-MPT4.46 HDL-MPT6.46
Professional Home and Building Automation Do you need help? Contact with us
support1@hdlchina.com.cn
www.hdlautomation.com 2/ 2
Dimensions and Wiring
HDL - MPT2.46
HDL - MPT4.46
HDL - MPT6.46
Installation: Hold the edge of panel (shown as above), insert the power interface module vertically. Do not
push the panel too hard.
Split: Insert a 2.5mm-screwdriver to the split gap, pry up from position 1 to 2,and then the wiring hole will open.
Then separate the panel and MPPI.46.
Glass plate replacement: Insert a small size straight screwdriver into the gap of the left side or right side of glass
cover (shown as above), to pick up the glass cover, then put the new cover in right place , then press the grey
area to lock the cover
Installation
1
2
Separate panel and power interface
Panel Panel power interface
(MPPI.46)
US wall box
Touch button function:On/off, dimming.
Address modification: Press any of button for 15s, all the backlights will flash, the address of this device can be
changed on HDL Buspro software: submenu ”address management→address modify”.
Signal interface and fastener: Connect to panel power interface (MPPI.46).
Split gap: Insert a slotted screwdriver to the split gap, separate the panel and power module (MPPI.46).
MPT6.46MPT4.46MPT2.46
Side view
10.5
Split gap
Signal interface
Fastener
Back view
83.5
Front view
116.5
86