HEART HA3020 User manual

Stand Alone Proximity Access ControllerHA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
1
STAND ALONE PROXIMTY
ACCESS CONTROLLER
OPERATION MANUAL
MODEL: HA3020
VERSION: 3.60
HEART ENTERPRISE CO. LTD.

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
2
zFeatures 3
zSpecification 3
zWiring Description 3
zInstallation 4
1.Wiring Diagram of HA3020 to HP1506 power pack 4
2.Wiring Diagram of HA3020 to HB0312 I/O relay board 5
zMain Function Description 5
1.Basic operation 5
2.Access modes three access modes selectable 5
3.Enrolment 5
4.Operation anti-duress 6
5.ARM/DISARM 7
6.Patrol function 7
7.Locate the last ten records 7
8.Review card data 7
9.Version check 8
10.Door bell function 8
zParameter Listing 8
zParameter Setting 8
1.Enrollment 8
2.Password Setting 12
3.Relay Time Setting 13
4.System Setting 15
zFactory Default List 24
zError/ Alarm Message 25

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
3
FEATURES
1. Proximity type reader, read range up to 10cm
2. Proximity card are less prone to physical damage or loss
3. Memory capacity store up to 5000 card holders
4. LCD display ,16 characters×2 lines with back light
5. Access mode selectable
(1). Card data
(2). Card data + password personal password or main password
(3). Card data or main password
6. Anti-duress function available
7. Patrol function available
8. Security function available
9. Personal password function
10. User card can be registered /deleted in batch mode
11. Authorize card to be removed once incorrect password key-in five times consecutively.
12. Alarm to be activated once incorrect password key-in five times within four minutes.
13. Last ten transaction history records available
14. Force entry alarm function available
15. Tamper alarm function available
16. Audible key tone available
17. Strike, alarm and duress relay drive time selectable (1-255 seconds)
18. Door left open time selectable (1-255 seconds)
19. Two-piece enclosure design the reader is patted for weather and hazard proofing
20. A separate relay module design, high security provided
21. With power saver function, the back light of LCD turn of f once there minutes
SPECIFICATION
Reader range :Up to 70mm (EM ISO-chip card 125 KHZ)
Display :16 characters * 2 lines LCD with back light
Keypad :12 key (0-9, *, #)
Memory Buffer :5,000 card holders
Indicator :Bi-color LED (Green / Red)
Case Material :ABS (UL 94V-0)
Dimension :150 (H) * 110 (W) * 45 (D) mm
Weight :380 g
Working voltage :DC 10- 15 volts
Power Consumption :300mA MAX
Operating temperature :0℃~50℃
Humidity :5﹪~95﹪(condensation)
Approved :IEC 529 IP34, CE, FCC
WIRING DESCRIPTION
Color Name Description
Red V+ +12VDC input from Controller
Black GND Ground
Brown CLK Clock signal to Controller
Orange DATA Data Signal to Controller
Yellow ACP AC Power failure input acknowledge from Controller. If
your system wiring to HB0312 no use in this line.

Stand Alone Proximity Access ControllerHA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
4
INSTALLATION
1. Wiring diagram of HA3020 to HP1506 power pack.
T2
T3
T5
T6
T7
T8
T1
T11
T15
T14
T13
T16
T9
T19
T20
T21
T18
T17
T12
T10
+12VDC
GND
Door Sensor
Aux Sensor
GND
Strike COM
Strike NC
Strike NO
Alarm COM
Alarm NC
Alarm NO
Duress COM
Duress NC
Duress NO
Guard COM
Guard NC
Guard NO
Patrol COM
Patrol NC
Patrol NO
Push Button
Elecric Bolt
+
EL A
T4
REDRED BLACKBLACK BROWNBROWN ORANGEORANGE YELLOWYELLOW
V+
CLK
GND
DATA
ACP
HA3020 SERIES
ACCESS CONTROL
SYSTEM
HP1506 WIRING DIAGRA
M
Alarm Siren
DIODE
Coil
PT
K1
K2
K3
K4
K5
J4
1
2
3
4
5
In general, fix the power pack at the top of the door ceiling. Connect the main unit and power pack with a
five-conductor strand, distant not larger then 150 meter.

Stand Alone Proximity Access ControllerHA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
5
T2
T3
T5
T6
T7
T8
T1
T11
T15
T14
T13
T16
T9
T19
T20
T21
T18
T17
T12
T10
+12VDC
GND
Door Sensor
Aux Sensor
GND
Strike COM
Strike NC
Strike NO
Alarm COM
Alarm NC
Alarm NO
Duress COM
Duress NC
Duress NO
Guard COM
Guard NC
Guard NO
Patrol COM
Patrol NC
Patrol NO
Push Button T4
AC Strike
A
C 24V
AC LOAD WIRING SCHEMATIC
Convert Relay
Alarm Siren
Diode
K1
K2
K3
K4
K5
Coil
2. Wring diagram of HA3020 to HB0312 I/O relay board
AEL
HB0312
STRIKE
ORANGE
BLACK
HA3020 SERIES ACCESS
CONTROL SYSTEM
Bolt
+
DOOR SENSOR
RED
PUSH BUTTON
GND
BROWN
ALARM
INPUT DC 12V
+12VDC
HB0312 STRUCTURE DIAGRA
M
EXIT BUTTON
K3
+12VDC
+12VDC
+12V
GND
DATA
CLOCK
DIODE
Coil
PT
1
2
3
4
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
ALARM SIREN
1
2
3
4
5
6
1
2
3
4
5
6
7
MAIN FUNCTION DESCRIPTION
1. Basic operation
HA3020 system use non-contact, proximity RF technology, just place the proximity card approach
the main unit to access the door.
2. Access modes: three access modes selectable:
(1) Card data only ”MODE 0” --- place the card approach the main unit to access the door.
(2) Card data or with main password or personal password ”MODE 1” --- place the card approach
the main unit AND then key-in the main password or personal password to access the door.
(3) Card data or main password “MODE 2” --- place the card approach the main password to
access the door.
3. Enrolment
Only the authorized card to be permitted to access the door, all new card should be enrolled before
used.

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
6
4.Operation anti-duress
With the anti-duress function provided, you no longer kidnap by thief. Key-in a preset code to the
rear of the regular password with ‘9’, the duress relay will be activated to drive the require device,
other then the door opened normally.
ACCESS MODE PROCEDURE LCD DISPLAY REMARK
MODE 0 Default Display READY FOR CARD
DC POWER ON
Press"12349#" CARD PLEASE Default the main
password is 1234,
Present proximity card WELCOME K3 activated
LED turn green
MODE 1 Present proximity card PASSWORD:
Press"12349#" WELCOME K3 activated
LED turn green
MODE 1 Press"12349#" CARD PLEASE:
Present proximity card WELCOME K3 activated
LED turn green
MODE 2 Press"12349#" WELCOME K3 activated
LED turn green
5.ARM/DISARM
HA3020 equipped a guard relay, which can arm or disarm the connected security system. Use
guard password or guardpassword plus card data toactivate this function, and guard password or
regular access procedure to deactivate this function.
6.Patrol function
This function provides the facility to monitor the watchman who patrols a certain district. HA3020
equipped a patrol a relay which can activated the connected recording system, you cannot access
the door neither use the patrol card or patrol password.
7. Locate the last ten records
The HA3020 store the last ten records in the memory use the following procedure to retrieve the
necessary data.
FUNCTION PROCEDURE LCD DISPLAY REMARK
Review the last ten
records Default Display READY FOR CARD
DC POWER ON
PRESS ’#’ 1.CHECK CARD NO.
2.RECORD CHECK Press ’*’ to abort
PRESS ’2’ LAST 1 11223344
Press’ 1 ’ÆScroll
PRESS ‘1’ LAST 2 11223344
Press’ 1 ’ÆScroll
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
8. Review card data
Function provided to read the internal code of card, procedure show below.
FUNCTION PROCEDURE LCD DISPLAY REMARK
Review the card data Default Display READY FOR CARD
DC POWER ON

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
7
PRESS ’#’ 1.CHECK CARD NO.
2.RECORD CHECK Press ’*’ to abort
PRESS ’1’ CARD PLEASE
000256 11223344
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
9. Version check
FUNCTION PROCEDURE LCD DISPLAY REMARK
Version check Default Display READY FOR CARD
DC POWER ON
PRESS ’#’ 1.CHECK CARD NO.
2.RECORD CHECK Press ’*’ to abort
PRESS ’0’ HEART ENTERPRISE
HA3020 V: 3.60
10. Door bell function
The HA3020 including doorbell function when you install with HP1506 power pack it will active at
relay K5.
FUNCTION PROCEDURE LCD DISPLAY REMARK
Door bell Default Display READY FOR CARD
DC POWER ON
PRESS ’0’ READY FOR CARD
DOOR BELL ON K5 activated
PARAMETER LISTING
The hierarchy diagram shows the relationship of each function

Stand Alone Proximity Access ControllerHA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
8
PARAMETER SETTING
1. Enrollment
Only the authorized card to be permitted to access the door; all new cards should be enrolled
before used. There are two categories: the access card which to be used to access the door, up to
5000 cards can be stored and put into operation; the patrol card use to monitor the watchmen who
patrol a certain district, more then 20 cards to be assigned neither patrol card or patrol password
can not access the door. Other then enrolls the card one by one, HA3020orivuded a batch mode
operation to simplify the procedure, just key-in the code of first and the total number of cards only.
The code of cards should be connected series. Example:
13480008
13480009
13480010
Main
function Function 1 Function 2 Function 3 Function 4 Function 5
1.ENROL 1.ACCESS CARD 1.S-ADD
2.S-DEL
3.B-ADD
4.B-DEL
2.PATROL CARD 1.S-ADD
2.S-DEL
2.PASSWD 1.MASTER
2.MAIN
3.PATROL
4.GUARD
3.TIMER 1.STRIKE
2.ALARM
3.DURESS
4.DB
4.SYSTEM 1.ALARM 1.TAMPER
2.FORCE
3.D-OPEN 1.FUNCTION
2.K2 ACTIVE
4.P-ERR
2.FORMAT 1.DELETE LOT NO
2.CHANGE FORMAT
3.MODE 1.ACCESS MODE
2.DI MODE 1.EXIT BUTTON
2.DOOR
3.PAUSE
3.READER
4.RESET
4.OTHER 1.TONE
2.PIN
3.DURESS
4.MORE 1.GUARD 1.FUNCTION
2.ARM
3.DISARM 1.CARD USE
2.STRIKE ACTIVE
2.PATROL
3.PAUSE
4.A-DEL

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
9
13480011
13480012
Add a new card (access card in MODE 0&2)
The following example assume the master code as "111111" (factory default) and no card in the
memory.
FUNCTION PROCEDURE LCD DISPLAY REMARK
Add a new card in
access MODE0&2 Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’1’ 1.ACCESS CARD
2.PATROL CARD
PRESS ‘1’ 1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL
PRESS ‘1’ AMOUNT :0
CARD NO.:
Present proximity card AMOUNT: 1
CARD NO.: 13480008
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Add a new card (access card in MODE 1)
The following example assume the master code as "111111" (factory default) and no card data in
the memory. You need to enable PIN function before enroll a new card in access mode 1.
FUNCTION PROCEDURE LCD DISPLAY REMARK
Enable PIN function
in access MODE 1 Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ‘4’ 1.TONE 2.PIN
3.DURESS 4.MORE
PRESS ‘2’ CURRENT: DISABLE
Press’1’ÆChange
PRESS ‘1’ CURRENT: ENABLE
Press’1’ÆChange Enable PIN function
PRESS ‘#’ READY FOR CARD
Add a new card in
access MODE 1 READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’1’ 1.ACCESS CARD
2.PATROL CARD
PRESS ‘1’ 1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL
PRESS ‘1’ AMOUNT :0
CARD NO.:
Present proximity card AMOUNT: 1
CARD NO.: 13480008
Amount: 1
PASSWORD:

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
10
PRESS ‘1666’ Amount: 1
PASSWORD: 1666
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Add the cards in batch mode
Example: the cards to be enrolled from 13480001 to 13480007 in batch mode.
FUNCTION PROCEDURE LCD DISPLAY REMARK
Add new card in
batch mode Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’1’ 1.ACCESS CARD
2.PATROL CARD
PRESS ‘1’ 1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL
PRESS ‘3’ AMOUNT: 0
CARD NO.:
Present proximity card CARD NO.: 13480001
TOTAL:
PRESS ‘7’ CARD NO.: 13480001
TOTAL: 7
Processing…7 Count down from 7
to 1
1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Delete a cards data
The following example assume the master code as "111111"(factory default), 7 cards pre-enrolled
already.
FUNCTION PROCEDURE LCD DISPLAY REMARK
Delete a card data Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’1’ 1.ACCESS CARD
2.PATROL CARD
PRESS ‘1’ 1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL
PRESS ‘2’ AMOUNT: 7
CARD NO.:
Present proximity card AMOUNT: 7
CARD NO.: 13480001
AMOUNT: 6
CARD NO.:
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Delete the cards in batch mode
The following example assume the master code as "111111"(factory default), 7 cards pre-installed
already .The cards to be input from 13480001 to 13480007, seven cards total

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
11
FUNCTION PROCEDURE LCD DISPLAY REMARK
Delete card data in
batch mode Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’1’ 1.ACCESS CARD
2.PATROL CARD
PRESS ‘1’ 1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL
PRESS ‘4’ AMOUNT: 7
CARD NO.:
Present proximity card CARD NO.: 13480001
TOTAL:
PRESS ‘7’ CARD NO.: 13480001
TOTAL: 7
Processing…7 Count down from 7
to 1
1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Add the patrol card
This example assume the master code as "111111" (factory default) and zero card data in the
memory:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Add a new patrol
card Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’1’ 1.ACCESS CARD
2.PATROL CARD
PRESS ‘1’ 1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL
PRESS ‘1’ AMOUNT :0
CARD NO.:
Present proximity card AMOUNT: 1
CARD NO.: 13480008
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Delete a patrol card
The following example assume the master code as "111111" (factory default) eight cards enrolled
already:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Delete a card data Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’1’ 1.ACCESS CARD
2.PATROL CARD
PRESS ‘2’ 1.S_ADD 2.S_DEL
3.B_ADD 4.B_DEL

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
12
PRESS ‘2’ AMOUNT: 8
CARD NO.:
Present proximity card AMOUNT: 8
CARD NO.: 13480001
AMOUNT: 7
CARD NO.:
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
2. Password Setting
Master password
In order to protect the internal parameter of the device,a master code is required when you want to
change some parameter inside, factory default is "111111”, you can change the code through the
following procedure:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Master password Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’2’ 1.MASTER 2.MAIN.
3.PATROL 4.GUARD
PRESS ‘1’ CURRENT: 111111
NEW:
PRESS ‘123456’ CURRENT: 111111
NEW: ******
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Main password
The main password (4 digits) used as a access code to access the door during the second (card
data plus password) access mode (MODE 1) default is "1234”, you can change the code through
the following procedure:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Main password Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’2’ 1.MASTER 2.MAIN.
3.PATROL 4.GUARD
PRESS ‘2’ CURRENT: 1234
NEW:
PRESS ‘5678’ CURRENT: 1234
NEW: ****
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Patrol password
The patrol password can be used to activated the equipped patrol relay (3 seconds) factory default
is " 1234567”, you can change the code through the following procedure:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Patrol password Default Display READY FOR CARD
DC POWER ON

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
13
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’2’ 1.MASTER 2.MAIN.
3.PATROL 4.GUARD
PRESS ‘3’ CURRENT: 1234567
NEW:
PRESS ‘7654321’ CURRENT: 1234567
NEW: *******
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Guard password
The Guard password (3 digits) can be bused to arm or disarm the connected security system,
factory default is "123" you can changed the code through the following procedure:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Guard password Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’2’ 1.MASTER 2.MAIN.
3.PATROL 4.GUARD
PRESS ‘4’ CURRENT: 1234
NEW:
PRESS ‘321’ CURRENT: 123
NEW: ***
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
3. Relay Time Setting
NOTICE: In order to protect the connected equipment, please consult the technical people before
adjust these following function.
Strike active time
This relay connected to the electric once somebody accesses the door. The active time depends
on the characteristic of the strike.
Please consult the technical people before adjust the relay time:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Strike time delay Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’3’ 1.STRIKE 2.ALARM
3.DURESS 4.DB
PRESS ‘1’ CURRENT: 5 SEC
NEW:
PRESS ‘10#’ CURRENT: 5 SEC
NEW: 10
PRESS ‘#’ CURRENT: 10 SEC
NEW:
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Alarm active time
The alarm relay can be activated by the following event:
1. Front panel destroyed by vandal

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
14
2. Forced entry
3. Door opened over the preset time
4. Incorrect password input five time
Please consult the technical people before adjust the relay time:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Alarm time delay Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’3’ 1.STRIKE 2.ALARM
3.DURESS 4.DB
PRESS ‘2’ CURRENT: 5 SEC
NEW:
PRESS ‘10#’ CURRENT: 5 SEC
NEW: 10
PRESS ‘#’ CURRENT: 10 SEC
NEW:
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Anti-duress active time
In general this relay connected to the alarm system, which for away the scene,
For example, the building management office, police, station. Etc.
Please consult the technical people before adjust the relay time:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Anti-duress active
time delay Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’3’ 1.STRIKE 2.ALARM
3.DURESS 4.DB
PRESS ‘3’ CURRENT: 5 SEC
NEW:
PRESS ‘10#’ CURRENT: 5 SEC
NEW: 10
PRESS ‘#’ CURRENT: 10 SEC
NEW:
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
An interval time of door left open (AJAR)
In general, the door could be closed within a preset time; otherwise the alarm system will be
activated. Please consult the technical people before adjust the relay time.
FUNCTION PROCEDURE LCD DISPLAY REMARK
AJAR time setting Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’3’ 1.STRIKE 2.ALARM
3.DURESS 4.DB
PRESS ‘4’ CURRENT: 5 SEC
NEW:

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
15
PRESS ‘10#’ CURRENT: 5 SEC
NEW: 10
PRESS ‘#’ CURRENT: 10 SEC
NEW:
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
4. System setting
To set up the following function through this sub-menu:
1. Enable or disable the alarm function that activated from difference reason.
2. Select the cards’ formal
3. Access mode selection
4. Others (key tone, personal password, duress function selection…etc)
Tamper alarm enable setting
HA3020 equipped a tamper switch for vandal resistance, use the following procedures to Enable
this function if require:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Tamper alarm enable
setting Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’1’ 1.TAMPER 2.FORCE
3.D_OPEN 4.P_ERR
PRESS ‘1’ CURRENT: DISABLE
Press’1’ÆChange
PRESS ‘1’ CURRENT: ENABLE
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Force entry setting (Enable / Disable)
The alarm will be activated when entry by force without regular access, card data or password, use
the following procedures to enable this function if require:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Force entry enable
setting Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’1’ 1.TAMPER 2.FORCE
3.D_OPEN 4.P_ERR
PRESS ‘2’ CURRENT: DISABLE
Press’1’ÆChange
PRESS ‘1’ CURRENT: ENABLE
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Door not close within a present time alarm (Enable/Disable)
The alarm will be activated when the door could not close within a preset time, use the following
procedures to Enable this function if require.

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
16
FUNCTION PROCEDURE LCD DISPLAY REMARK
AJAR function
enable setting Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’1’ 1.TAMPER 2.FORCE
3.D_OPEN 4.P_ERR
PRESS ’3’ 1.FUNCTION
2.K2 ACTIVE
PRESS ‘1’ CURRENT: DISABLE
Press’1’ÆChange
PRESS ‘1’ CURRENT: ENABLE
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Alarm relay to be activated when door not closed within a preset time
The built-in buzzer will activate, a "door opened" message shown on LCD when door would not
closed within a present time. Enable this function in if external alarm is required.
FUNCTION PROCEDURE LCD DISPLAY REMARK
AJAR relay enable
setting Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’1’ 1.TAMPER 2.FORCE
3.D_OPEN 4.P_ERR
PRESS ’3’ 1.FUNCTION
2.K2 ACTIVE
PRESS ‘2’ CURRENT: DISABLE
Press’1’ÆChange
PRESS ‘1’ CURRENT: ENABLE
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Alarm activated when incorrect password key-in five times within four minutes
Use the following procedure to Enable or Disable this function:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Pin error alarm enable
setting Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’1’ 1.TAMPER 2.FORCE
3.D-OPEN 4.P-ERR
PRESS ‘4’ CURRENT: DISABLE
Press’1’ÆChange

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
17
PRESS ‘1’ CURRENT: ENABLE
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Delete lot number
If 40 Bits format selected (refer to section “Change Format” HA3020 store the whole effective
length in to two parts, the higher bit group (16Bits) and lower bit group (24Bits) Use the following
procedures to delete the higher bit group if require
FUNCTION PROCEDURE LCD DISPLAY REMARK
Card lot number
delete setting Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’2’ 1.DELETE LOT NO
2.CHANGE FORMAT
PRESS ’1’ AMOUNT: 2
LOT NO.:
Present would like to
delete card AMOUNT: 1
LOT NO.:
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Change card format
The effective bit length of proximity card is 40Bits, the sample to take by HA3020 are as follows:
1. Lower 24 Bits only (Factory default)
2. 2.whole 24Bits
More then sixteen million combination staff no be used when lower 24 Bits to be selected. Use the
following procedures to adjust the standard.
FUNCTION PROCEDURE LCD DISPLAY REMARK
Change card format Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’2’ 1.DELETE LOT NO
2.CHANGE FORMAT
PRESS ‘2’ CURRENT: 24 BITS
Press’1’ÆChange
PRESS ‘1’ CURRENT: 40 BITS
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Door access mode selection
HA3020 has three-access mode selection
1. Card data only (Mode 0)
2. Card data plus password; main password or personal password (Mode 1)
3. Card data or main password (Mode 2)
Choose the second when higher security requires; use the following procedure to make your
selection:

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
18
FUNCTION PROCEDURE LCD DISPLAY REMARK
Door access MODE 1
selection Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’3’ 1.ACCMOD2.DI_M
3.READER 4.RESET
PRESS ‘1’ CURRENT: MODE 0
Press’1’ÆChange Default Mode 0
PRESS ‘1’ CURRENT: MODE 1
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Polarity of three input point selection
HA3020 provides three input points which function show as following:
1. Egress button point
2. Door state detection point
3. Pause control point
The polarity of these point can be changed when require ( NO→normal open ; NC→normal
close )
Polarity of egress button selection (NC/NO)
The following example assume the master code as “111111”, egress button point as “NO” state
(factory default)
FUNCTION PROCEDURE LCD DISPLAY REMARK
Egress button
polarity selection Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’3’ 1.ACCMOD2.DI_M
3.READER 4.RESET
PRESS ’2’ 1.EXIT BUTTON
2.DOOR 3. PAUSE
PRESS ‘1’ CURRENT: NO
Press’1’ÆChange
PRESS ‘1’ CURRENT: NC
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Polarity of door detector selection (NC/NO)
The following example assume the master code as “111111”door detector point as “NO” state
(factory default)
FUNCTION PROCEDURE LCD DISPLAY REMARK
Door sensor polarity
selection Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
19
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’3’ 1.ACCMOD2.DI_M
3.READER 4.RESET
PRESS ’2’ 1.EXIT BUTTON
2.DOOR 3. PAUSE
PRESS ‘2’ CURRENT: NO
Press’1’ÆChange
PRESS ‘1’ CURRENT: NC
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Polarity of pause contact selection (NC/NO)
The following example assume the master code as “111111” pause contact point as “NO” state
(factory default):
FUNCTION PROCEDURE LCD DISPLAY REMARK
Door sensor polarity
selection Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’3’ 1.ACCMOD2.DI_M
3.READER 4.RESET
PRESS ’2’ 1.EXIT BUTTON
2.DOOR 3. PAUSE
PRESS ‘3’ CURRENT: NO
Press’1’ÆChange
PRESS ‘1’ CURRENT: NC
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Reader format selection
HA3020 can be changed proximity reader to HID 26 bits format wiegand reader setting as following
example assume the master code as “111111” pause contact point as “NO” state (factory default):
FUNCTION PROCEDURE LCD DISPLAY REMARK
Reader format
selection Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’3’ 1.ACCMOD2.DI_M
3.READER 4.RESET
PRESS ‘3’ CURRENT: HEART
Press’1’ÆChange
PRESS ‘1’ CURRENT: HID_W26
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Clear all of stored card data

Stand Alone Proximity Access Controller
HA3020
HEART ENTERPRISE CO., LTD. 5.01.2002
20
NOTICE: In order to protect the connected equipment, please consult the technical people before
adjust this function.
If you have to clear all of stored card data setting as following example assume the master code as
“111111” pause contact point as “NO” state (factory default):
FUNCTION PROCEDURE LCD DISPLAY REMARK
Clear all stored card
data Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’3’ 1.ACCMOD2.DI_M
3.READER 4.RESET
PRESS ‘4’ PRESS 1
TO RESET UNIT
PRESS ‘1’ PASSWORD:
PRESS ’111111#’ PRESS 1
TO RESET UNIT Default master
code’111111’
PRESS ‘1’ EEPROM EARSING
READY FOR CARD
End of operation
Beeper sound of keys selection (Enable / Disable)
A beeper sound comes out when a key being pressed (factory default Æenable), use the following
procedure to disable this function when require:
FUNCTION PROCEDURE LCD DISPLAY REMARK
Beeper tone enable Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
PRESS ’4’ 1.ALARM 2.FORMAT
3.MODE 4.OTHER
PRESS ’4’ 1.TONE 2.PIN
3.DURESS4.MORE
PRESS ‘1’ CURRENT: DISABLE
Press’1’ÆChange
PRESS ‘1’ CURRENT: ENABLE
Press’1’ÆChange
PRESS ‘#’
Or time out in 15 sec READY FOR CARD
End of operation
Personal password function selection (Enable / Disable)
The personal password to be used in the second access mode 2 in which means card data with
password.
FUNCTION PROCEDURE LCD DISPLAY REMARK
PIN function enable Default Display READY FOR CARD
DC POWER ON
PRESS ’111111#’ 1.ENROLL 2.PASSWD.
3.TIMER 4.SYSTEM Default master
code’111111’
Table of contents
Other HEART Controllers manuals