HEART HR4136-B1 User manual

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
2
Compilation:2022/03/30
Introduction:
Thank you for purchasing the HR4136-B1 CIDRW System.
Please observe the following points when operating the HR4136-B1:
• Please read and understand the content of this manual before using the system.
• After reading this manual, store it in a handy location for easy reference whenever necessary.
Precautions in using the product
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your HEART TECH representative if
you have any questions or comments.
WARRANTY
HEART TECH’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of
one year (or other period if specified) from date of sale by HEART TECH.
HEART TECH MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING
NONINFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY
BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. HEART DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
HEART TECH SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of HEART TECH for any act exceed the individual price of the product on which liability is
asserted.
IN NO EVENT SHALL HEART BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS HEART’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED,
STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR
INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR
RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT
OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for HEART TECH 's safety rated
products.
HEART TECH shall not be responsible for conformity with any standards, codes, or regulations that apply to the
combination of products in the customer’s application or use of the product.
At the customer’s request, HEART TECH will provide applicable third party certification documents identifying ratings and
limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the
suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an
exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the
products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not
described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment,

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
3
amusement machines, vehicles, safety equipment, and installations subject to separate industry or government
regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE HEART PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not
constitute a warranty. It may represent the result of HEART TECH’s test conditions, and the users must correlate it to
actual application requirements. Actual performance is subject to the HEART TECH Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant
construction changes are made. However, some specifications of the product may be changed without any notice. When
in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your
request. Please consult with your HEART TECH representative at any time to confirm actual specifications of purchased
products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are
shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
HEART TECH shall not be responsible for the user’s programming of a programmable product, or any consequence
thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us
before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this
document to another, please copy or transmit it in its entirety.
FCC WARNINGS
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference and followed, read and understood by all persons working with
the device (especially the safety information)
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, in accordance with part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual,may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception - this can be determined by turning the equipment off and on -the user is encouraged to try to correct the
interference using one or more of the following measures:
Reposition or relocate the receiving antenna.
Increase the distance between the equipment and the receiver.
Connect the equipment to an outlet to a circuit other than the one to which the receiver is connected.

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
4
Consult the dealer or an experienced radio/TV technician for assistance.
FCC ID : 2AB67-HR4136-B1
Compliance with :
FCC Code of Fedral Requlations,Part 15 Subpart C, Section §15.205
FCC Code of Fedral Requlations,Part 15 Subpart C, Section §15.209
WARNING
Changes or modifications not expressly approved by the party
responsible for compliance may void the user's authority
to operate the equipment.
Connector Description:
DC 10 ~ 24V:DC Input
Function:Setup Baud Rate,Buzzer ON/OFF,Self-test ON/OFF
Address:Setup address 00 ~ 99
ST:Status LED
TX:Data transmit LED
RX:Data received LED
ANT:Antenna terminal block
RS232:RS232 commnuications port
RS485:RS485 communications port
Baud Rate
Buzzer Self-test
21
3 4
OFFOFF
OFFON
ONOFF
ONON
Switch
Function
Switch
4800
9600
19200
28800
4
5
6
Ground
Pin No. RS232
RXD
TXD
R+ / D+
RS485
R- / D-
FUNCTION ADDRESSDC 10~24V
+
-
ST TX RX
ON
1 2 3 4
0 0
ANT RS232 RS485

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
5
Installation:
CIDRW Controller
Mount the CIDRW Controller with the two M3 - M4 screws.
Note:
Tighten the M3 - M4 screws with a torque not exceeding 1.2 Nm.
Do not apply organic solvents used with screw locking agents at the locations where the
screws are inserted.

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
6
Antenna
Stick antenna
12.4
Rectangular antenna
22mm
32mm
15mm
Note:Mount with the two M3 - M4 plastic screws .
Champ Core Installation Instructions

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
7
Wiring Diagram:
ANT RS232 RS485
4
5
6
Ground
Pin No. RS232
RXD
TXD
RS485
R- / D-
R+ / D+4
5
Pin No.
Antenna cable length : 2M with RP-TNC connecter

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
8
Systems Architecture:
RS232 RS485
Ethernet
10/100M
ADDRESSDC 10~24V
+
-
ST TX RX
FUNCTION
ON
1 2 3 4
0 0
ANT RS232 RS485ANT RS232 RS485
ANT RS232 RS485ANT RS232 RS485
ANT RS232 RS485ANT RS232 RS485
HR4136-B
CID R/W Controller
Max. 25 set.
HR4135 Gate Controller
HR4136-B
CID R/W Controller
Max. 25 set.
Total 1000m Max.
1. Each HR4135 gate controller has two RS485 communication ports. Each RS485 communications
port Maximum connections of 32 sets HR4136-B1 CIDRW controller. Recommended maximum
number of connections each RS485 communications port is not over 25 sets HR4136-B1 CIDRW
controller.
2. RS485 maximum connection distance: from HRP485 Repeater to last one HR4136-B1 CIDRW
Controller total 1000 m.

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
9
MODEL HRP485
RS485 REPEATER
MODEL HRP485
RS485 REPEATER
1. Use HRP485 Repeater can be connected up to 99 set HR4136-B1 CIDRW Controller.
2. RS485 the maximum connection distance: from HRP485 Repeater to last one HR4136-B1 CIDRW
Controller total 1000 m.

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
10
Transmission Area (information only):
Stick antenna
Tag : TEXAS INSTRUMENTS 32mm Glass Transponder part number RI-TRP-DR2B
The transmission area diagram going through the center of the antenna and indicated on a flat surface
vertical to the antenna surface is as indicated below.
X01122334455667788 99 10 11
Legend :
Normal area
Recommended area
Unrecommended area
X
Y

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
11
Rectangular antenna
Tag : TEXAS INSTRUMENTS 32mm Glass Transponder part number RI-TRP-DR2B
The transmission area diagram going through the center of the antenna and indicated on a flat surface
vertical to the antenna surface is as indicated below.

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
12
General specifications:
Characteristic Specification Comment
Supply Voltage Range DC 10 ~ 24V (+/-10%) Supplied from the power terminals
Current consumption @12VDC Average 60mA ; Peak 160mA Approx. 2A max, with rush current
Transmitting Radio Frequency Typical 134.2KHz FSK
Transponder Type TIRIS Tag Single & Multi page Transponder
Operating ambient
temperature -10 ~ +70°C No freezing
Operating ambient humidity 10 ~ 85%RH No dew condensation
Storage ambient temperature -20 ~ +85°C No freezing
Storage ambient humidity 5 ~ 95%RH No dew condensation
Communication interface RS-232C or RS-485 9600 bps (Default), N.8.1 (fixed)
Weight 450g MAX. No freezing
Dimensions 147 × 110 × 32 mm Except for protrusions on connectors
Mounting system Secured with two M3 screws. Use the enclosed washers.
Communication interface specification:
Characteristic Specification
Connector specification RJ45 connector plug
Communication standard RS-232C or RS-485 only for used HR4135 Gate Controller
Synchronization Asynchronous mode, start-stop synchronization
Communications control standard SEMI/SECS protocol for HR4136-B1 CID Read/Write controller
Baud rate 4800,9600,19200,28800 bps (Default 9600)
Character format (fixed)
Start bit Data bit Parity bit Stop bit Total
1 8 None 1 10
Error control FCS (Frame Check Sequence)
Total cable length RS-232C 15 m Max. ;
RS-485 : From HR4135 to last one HR4136-B1 Total 1000 m Max.

HR4136-B1
HEART TECH ENTERPRISE CO., LTD. BEST SERVICE FROM HEART
13
DIP Switch settings specifications:
SW No. Name Description
1 ~ 2 Baud rate
SW 4800 9600 19200 28800
1 OFF ON OFF ON
2 OFF OFF ON ON
3 Beeper status ON The beeper is enabled when a correct Stream Function executed.
OFF The beeper is disabled.
4 Test mode ON The controller automatic read tag RFID repeatedly.
OFF Normal operation.
Table of contents