Renishaw UCC PI 80 User manual

General information
© 2018 ‐ 2019 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without
the prior written permission of Renishaw.
The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
Disclaimer
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF
PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY,
HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.
Trademarks
RENISHAW® and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries.
apply innovation is a trademark of Renishaw plc.
All brand names and product names used in this document are trade names, service marks, trademarks, or registered trademarks of their
respective owners.
All trademarks and trade names are acknowledged.
WEEE
The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with the
general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for
waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help save valuable
resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service
or Renishaw distributor.
Warranty
Renishaw plc warrants its equipment for a limited period (as set out in our Standard Terms and Conditions of Sale) provided that it is installed
exactly as defined in associated Renishaw documentation.
Prior consent must be obtained from Renishaw if non-Renishaw equipment (e.g. interfaces and/or cabling) is to be used or substituted. Failure
to comply with this will invalidate the Renishaw warranty.
Claims under warranty must be made from authorised service centres only, which may be advised by the supplier or distributor.
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
2

Care of equipment
Renishaw probes and associated systems are precision tools used for obtaining precise measurements and must therefore be treated with
care.
Changes to Renishaw products
Renishaw reserves the right to improve, change or modify its hardware or software without incurring any obligations to make changes to
Renishaw equipment previously sold.
Packaging
To aid end user recycling and disposal the materials used in the different components of the packaging are stated here:
Packaging component Material 94/62/EC code 94/62/EC number
Outer box Cardboard - 70% recycled
content PAP 20
Packing foam Polyurethane PU 7
Packing foam Cross-linked polyethylene LDPE 4
Plastic bags Low density polyethylene bag LDPE 4
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
3

Product compliance
EU declaration of conformity
Contact Renishaw plc or visit www.renishaw.com/EU for the full EU declaration.
FCC (USA only)
Information to user (47 CFR 15.105)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference, in which case you will be required to correct the interference at your own expense.
Information to user (47 CFR 15.21)
The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could void the
user's authority to operate the equipment.
Equipment label (47 CFR 15.19)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
REACH regulation
Information required by Article 33﴾1﴿ of Regulation ﴾EC﴿ No. 1907/2006 ﴾“REACH”﴿ relating to products containing substances of very high
concern (SVHCs) is available at:
www.renishaw.com/REACH
China RoHS
Contact Renishaw plc or visit www.renishaw.com/ChinaRoHS for the full China RoHS tabulation.
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
4

Safety
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
There are no user serviceable parts inside the equipment.
The UCC PI 80 controller is only warranted and approved for use with the provided PSU.
The UCC PI 80 is isolated from ac power by disconnection of the IEC mains connector from the supplied PSU. If any additional means of
isolation is required, it must be specified and fitted by the machine manufacturer or installer of the product. The isolator / disconnection
device must be sited within easy reach of the operator and comply with IEC61010 and any applicable national wiring regulations for the
country of installation.
WARNING: Earthing of the UCC PI 80 is required. It is the responsibility of the OEM or installer to apply the earth bonding scheme
provided by Renishaw in this installation guide.
WARNING: The system can accelerate quickly during operation. The user must not enter the working volume of the CMM until all
power is removed. When within the working volume of the CMM, the user should wear eye protection.
WARNING: UCC PI 80 is isolated from ac power by disconnection of the IEC mains connector from the supplied PSU.
WARNING: Switching off or isolating the UCC PI 80 may NOT prevent unexpected machine movement. The user is advised to
isolate the machine from the electricity supply, compressed air or other energy sources in accordance with the machine
manufacturer's instructions before entering the danger zone or performing any maintenance operations.
CAUTION: It is strongly recommended that the CMM manufacturer or retrofitter includes in their maintenance instructions a
periodic test of the emergency stop and, if fitted, the associated reset switch.
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
5

Environmental conditions
Indoor use IP30 (BS EN60529:1992)
Altitude Up to 2000 m
Operating temperature +5 °C to +50 °C
Storage temperature ‐25 °C to +70 °C
Relative humidity for storage 90% maximum ﴾non‐condensing﴿ for temperatures up to +42 °C
Pollution degree 2
NOTE: If the UCC PI 80 is to be used in an environment where a higher IP rating is required, then the UCC PI 80 will need to be
housed in a suitable enclosure.
NOTE: The electrical input requirements to the provided PSU can be found on the PSU label.
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
6

References and associated documents
It is recommended that the following documentation is referenced when installing the UCC PI 80:
Renishaw documents
Title Document number
Installation guide: SP80 H-1000-5212
Installation guide: UCC BI H-1000-7602
Installation guide: UCC AI H-1000-7611
Installation guide: UCC T3 PLUS and UCC S3 H-1000-2118
Installation guide: UCC T3-2 H-1000-5254
Installation guide: UCC T5 H-1000-7573
Installation guide: UCC S5 H-1000-7598
Installation guide: SPA2-2 H-1000-5247
Installation guide: SPA3 H-1000-7566
Installation and user's guide: MCU H-1000-5182
Installation and user's guide: MCU5-2 and MCU W-2 H-1000-5280
Guide: Product interconnection system (PICS) H-1000-5000
UCCassist-2 help Found within UCCassist-2
External documents
National and international standards including the following may be applicable to the finished machine or installation:
EN 60204-1:2006/A1:2009 (Safety of machinery - Electrical equipment of machines - Part 1: General requirements)
BS EN 61010-1:2010 (Safety requirements for electrical equipment for measurement, control and laboratory use. General requirements)
BS EN ISO 13849-1:2015 and BS EN ISO 13849-2:2008 (Safety of machinery. Safety-related parts of control systems)
BS EN ISO 12100:2010 (Safety of machinery - General principles for design - Risk assessment and risk reduction)
It is the responsibility of the OEM or installer to ensure that the finished installation complies with applicable national regulations for the
country of installation.
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
7

Introduction
The UCC PI 80 is required for CMM systems which are fitted with Renishaw's SP80 scanning probe and facilitates the use of the UCC S3 as the
machine controller.
If the CMM system uses brushless motors, then the UCC PI 80 may be connected to a Renishaw SPA2-2 which provides power. Please see the
UCC BI user guide (Renishaw part number H-1000-7602) for configuration instructions.
If the CMM system uses motors which are not supported by Renishaw SPA products (e.g. above 80 V or 10 A), then the UCC PI 80 may be
connected to a third party analogue amplifier to provide power. Please see the UCC AI installation guide for configuration instructions.
Key Description Key Description
1Scale 0 interface (15W HDD
socket) *9UCC - EXP (RJ45 socket)
2Scale 1 interface (15W HDD
socket) *10 UCC - SPA (RJ45 socket) *
3Scale 2 interface (15W HDD
socket) *11 SPA - A (RJ45 socket) **
4Scale 3 interface (15W HDD
socket) *12 SPA - B (RJ45 socket) **
5SP80 interface (15W D socket) 13 MCU (9W D plug) *
6Machine I/O (44W HDD socket) *14 Servo power amplifier / E-STOP
(25W D socket) *
7RS232 (9W D plug) *15 Earth terminal
8PICS (9W D socket) *16 UCC PI 80 power jack (6.3 mm
socket)
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
8

* NOTE: Only to be used when interfacing to an SPA2-2 (see the UCC BI installation guide, Renishaw part number H-1000-7602)
or when using a third party amplifier (see the UCC AI installation guide, Renishaw part number H-1000-7611), otherwise the SPA3
/ SPA3-2 connections should be used.
** NOTE: Only to be used when interfacing to an SPA2-2 (see UCC BI installation guide, Renishaw part number H-1000-7602).
WARNING: The capability to connect the UCC PI 80 to a third party analogue amplifier requires UCCsuite v5.3 or newer.
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
9

Connectivity
The UCC PI 80 has different configuration layouts to provide an interface to CMM systems with three, four or five machine axes, whether
brushed or brushless motors.
NOTE: The UCC S3 needs to be version V.2 or newer - see label on rear panel (first shipped February 2015).
3-axis CMM with brushed motors
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
10

System components
The part numbers of the UCC PI 80 kits and upgrades are:
Kit Part number
SP80 controller kit 1 (contains UCC S3, SPA3, UCC PI 80, MCU5-2,
PSU, connector kit) A-5518-1200
SP80 controller kit 2 (contains UCC S3, SPA3, UCC PI 80, connector
kit) A-5518-1203
SP80 controller kit 3 (contains UCC S3, SPA3, UCC PI 80, MCU5-2,
connector kit) A-5518-1205
SP80 controller kit 4 ﴾contains UCC S3, 2 × SPA3, UCC PI 80, MCU5‐
2, 2 × PSU, connector kit﴿
A-5518-1207
Accessories Part number
Connector kit A-5518-0010
Bracket kit A-5518-0005
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
14

General wiring standards
To achieve reliable operation of the UCC PI 80 the following should be observed:
All signal cables MUST be screened and all cable screens should be connected electrically to the cable connector's metal shells.
It is recommended that cable screens should only be connected to the functional earth (via the connector shell) of the UCC PI 80. To avoid
earth loops, cable screens should not be directly attached to the CMM's functional earth.
The grounding must be continuous between all equipment in the installation.
All cable connectors should be secured to the UCC PI 80 and SPA (where present) by the connector jack screws.
NOTE: When used for SP80 only, with an SPA3 and UCC S3, the amplifier ground will be connected to the UCC PI 80 ground
through the UCC S3.
Naming convention
Function Description
signal active high
/signal/ (active low)
reserved Do not use. For Renishaw purposes only.
signal + Positive differential pair
signal - Negative differential pair
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
15

Installation
Dimensions
Width Depth Height Weight
440 mm (17.3 in) 180 mm (7.1 in) 44 mm (1.7 in) 2.4 kg (5 lb 3 oz)
UCC PI 80 can either be free standing or used in a 19 inch rack system.
WARNING: Ensure the UCC PI 80 is disconnected from the mains supply during installation.
Free-standing installation
The UCC PI 80 unit draws air from the right hand side when viewed from the front and expels air out of the left hand side. A minimum
clearance gap of 10 mm is necessary between the sides of the unit and any obstruction. The dimensions shown on the above drawing are in
mm (in).
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
16

Mounting in a 19 inch rack (optional)
NOTE: The screws supplied with this kit are M5 × 6 mm countersink type.
The rack mounting kit (Renishaw part number A‐5518‐0005﴿ contains two brackets and four M5 × 6 mm screws. Assemble the brackets to
the UCC PI 80 as shown below:
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
17

Earth bonding scheme
* NOTE: May be protective earth where appropriate for electrical safety.
CAUTION: The capability to use the UCC PI 80 in a dual SPA system or a system using absolute scales is not yet available, please
contact CMM support for further information.
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
18

Software installation
Support for the UCC PI 80 is included in UCCsuite version 5.3 and onwards. All recommended updates for any of the system components
must be installed for correct operation.
NOTE: The UCC S3 needs to be version V.2 or newer - see label on rear panel (first shipped February 2015).
The UCCassist-2 application included in this software release will allow the user to correctly configure the system to use the UCC controller to
interface to the UCC PI 80.
The software can be obtained online at www.renishaw.com/cmmsupport or from your local Renishaw supplier. Follow the prompts to install
the UCCsuite software.
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
19

Connectors and signals
This section contains information on the following UCC PI 80 ports:
SP80 interface socket (15W D socket)
UCC - EXP (RJ45 socket)
UCC PI 80 power socket (6.3 mm socket)
Key Description Key Description
1Scale 0 interface (15W HDD
socket) *9UCC - EXP (RJ45 socket)
2Scale 1 interface (15W HDD
socket) *10 UCC - SPA (RJ45 socket) *
3Scale 2 interface (15W HDD
socket) *11 SPA - A (RJ45 socket) **
4Scale 3 interface (15W HDD
socket) *12 SPA - B (RJ45 socket) **
5SP80 interface (15W D socket) 13 MCU (9W D plug) *
6Machine I/O (44W HDD socket) *14 Servo power amplifier / E-STOP
(25W D socket) *
7RS232 (9W D plug) *15 Earth terminal
8PICS (9W D socket) *16 UCC PI 80 power jack (6.3 mm
socket)
* NOTE: Only to be used when interfacing to an SPA2-2 (see the UCC BI installation guide, Renishaw part number H-1000-7602)
or when using a third party amplifier (see the UCC AI installation guide, Renishaw part number H-1000-7611), otherwise the SPA3
/ SPA3-2 connections should be used.
** NOTE: Only to be used when interfacing to an SPA2-2 (see UCC BI installation guide, Renishaw part number H-1000-7602).
UCC PI 80 installation guide
www.renishaw.com
Issued 07 2019
20
Table of contents
Other Renishaw Controllers manuals

Renishaw
Renishaw UCC S5 REVO-2 User manual

Renishaw
Renishaw MCU5 User manual

Renishaw
Renishaw UCC T5 User manual

Renishaw
Renishaw UCC MMI-2 User manual

Renishaw
Renishaw UCClite-2 User manual

Renishaw
Renishaw UCC T3 User manual

Renishaw
Renishaw PHC10-3 PLUS User manual

Renishaw
Renishaw PHC10-3 PLUS User manual

Renishaw
Renishaw UCC1 User manual

Renishaw
Renishaw UCC T3-2 User manual