Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
Ref No GMK10486
ASNZS 5263.1.3:2016
Installation Manual
Installation and Appliance Setup
Models:
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions regarding installation, operation or service.
NOTICE: DO NOT discard this manual!
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
• DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
- If you cannot reach your gas supplier, call
the re department.
• Installation and service must be performed
by a qualied installer, service agency, or the
gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
350X-AU
550X-AU
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
DO NOT MODIFY THIS APPLIANCE.
NOTE: NOT INTENDED FOR
FIREPLACE INSERT.

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
2
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
Installation Standard Work Checklist....................3
1 Product Specic and Important Safety Information
A. Appliance Certication ............................4
B. Glass Specications..............................4
C. Gas Pressure Requirements .......................4
D. Gas Pressure Requirements .......................4
E. High Altitude Installations ..........................4
F. Non-Combustible Materials Specication. . . . . . . . . . . . . . 4
G. Combustible Materials Specication .................4
H. Electrical Codes .................................4
2 Getting Started
A. Design and Installation Considerations ...............5
B. Good Faith Wall Surface/TV Guidelines ..............5
C. Tools and Supplies Needed ........................5
D. Inspect Appliance and Components..................6
3 Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams .......7
B. Clearances to Combustibles .......................9
C. Constructing the Appliance Chase .................. 11
D. Floor Protection ................................ 11
4 Termination Location and Vent Information
A. Vent Termination Minimum Clearances ..............12
B. Chimney Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
C. Approved Pipe .................................14
D. Use of Elbows .................................14
E. Measuring Standards ............................15
F. Vent Diagrams .................................16
5 Vent Clearances and Framing
A. Pipe Clearances to Combustibles ..................29
B. Wall Penetration Framing/Firestops .................30
C. Ceiling Firestop/Floor Penetration Framing ...........31
D. Install Attic Insulation Shield.......................31
6 Appliance Preparation
A. Vent Collar Preparation ..........................32
B. Installing the Optional Heat-Zone®-240V Kit .......... 34
C. Securing and Leveling the Appliance ................34
D. Non-Combustible Material ........................34
7 Venting and Chimneys
A. Assemble Vent Sections .........................35
B. Assemble Slip Sections ..........................36
C. Secure the Vent Sections.........................37
D. Disassemble Vent Sections ....................... 37
E. Vertical Termination Requirements.................. 38
F. Horizontal Termination Requirements ...............39
8 Electrical Information
A. General Information .............................41
B. Wiring Requirements ............................42
C. Fan ..........................................43
D. Control Module Operation ........................43
9 Gas Information
A. Fuel Conversion ................................44
B. Gas Pressure ..................................44
C. Gas Service Access .............................44
D. High Altitude Installations ......................... 44
E. Air Shutter Setting ..............................45
F. Burner Identication/Verication....................46
10 Finishing
A. Facing Material.................................47
B. Mantel and Wall Projections.......................48
C. Decorative Front Finishing ........................49
11 Appliance Setup
A. Remove Fixed Glass Assembly ....................50
B. Remove the Shipping Materials ...................50
C. Clean the Appliance ............................. 50
D. Setup Overview ................................50
E. Install Hearth Components, Teco-Sil, Glowing Embers®
Refractory and Logs.............................50
F. Install and Paint Teco-Sil .........................51
G. Install Logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
H. LED’s ........................................55
I. Install Fixed Glass Assembly ...................... 55
J. Install Decorative Front ..........................55
K. Appliance Operation.............................55
12 Reference Materials
A. Vent Components Diagrams ......................56
B. Accessories ...................................62
= Contains updated information.

3
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
Installation Standard Work Checklist
Customer:
Lot/Address:
Model (circle one): 350X-AU, 550X-AU
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
Serial #:
Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective
action needed _____________________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________
Comments Communicated to party responsible ____________________ by ______________________on ___________
(Builder / Gen. Contractor/) (Installer) (Date)
Appliance Install YES IF NO, WHY?
Veried that the chase is insulated and sealed. (Pg. 11) ___________________________
Required non-combustible board is installed. (Pg. 34) ___________________________
Veried clearances to combustibles. (Pg. 9-10) ___________________________
Fireplace is plum, level, square and secured. (Pg. 34) ___________________________
Venting/Chimney Section 7 (Pg 35-40)
Venting conguration complies to vent diagrams. ___________________________
Venting installed, locked and secured in place with proper clearance. ___________________________
Firestops installed. ___________________________
Attic insulation shield installed. ___________________________
Exterior wall/Roof ashing installed and sealed. ___________________________
Terminations installed and sealed. ___________________________
Electrical Section 8 (Pg 35-40)
Unswitched power (110-120 VAC) provided to the appliance. ___________________________
Switch wires properly installed. ___________________________
Gas Section 9 (Pg 41-43)
Proper appliance for fuel type. ___________________________
Was a conversion performed? ___________________________
Leak check performed and inlet pressure veried. ___________________________
Veried proper air shutter setting for installation type. ___________________________
Finishing Section 10 (Pg 47-49)
Combustible materials not installed in non-combustible areas. ___________________________
Veried all clearances meet installation manual requirements. ___________________________
Mantels and wall projections comply with installation manual requirements. ___________________________
Appliance Setup Section 11 (Pg 50-55)
All packaging and protective materials removed (inside & outside of appliance). ___________________________
Refractories, logs, media and embers installed correctly. ___________________________
Glass assembly installed and secured. ___________________________
Accessories installed properly. ___________________________
Mesh, doors, or decorative front properly installed. ___________________________
Manual bag and all of its contents are removed from inside/under
the appliance and given to party responsible for use and operation. ___________________________
Started appliance and veried no gas leaks exist. ___________________________
2279-982 12/17
= Contains updated information.
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your le.
• That this checklist remain visible at all times on the appliance until the installation is complete.
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this
installation manual.
WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions could
lead to a re or explosion.
ATTENTION INSTALLER:
Follow this Standard Work Checklist

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
4
1 Product Specic and Important Safety Information
A. Appliance Certication
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Specications
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
MODELS: 350X-AU, 550X-AU,
LABORATORY: IAMPO OCEANA
TYPE: Direct Vent Heater
STANDARD: AS/NZS 5263.1.3:2016
NOTE: The gas control valve supplied with this product is approved for a maximum inlet pressure of
3.40 kPa. For pressures over 3.40 kPa, an in line pressure regulator must be installed upstream from the gas control valve.
350X-AU 550X-AU
NATURAL GAS PROPANE BUTANE NATURAL GAS PROPANE BUTANE
Inlet Gas Pressure 1.13 - 3.40 kPA 2.75 - 3.40 kPA 2.75 - 3.40 kPA 1.13 - 3.40 kPA 2.75 - 3.40 kPA 2.75 - 3.40 kPA
* Outlet (Manifold)
Gas Pressure .87 kPA 2.40 kPA 2.40 kPA .87 kPA 2.40 kPA 2.40 kPA
Max. Gas Con-
sumption 21 19 17 28 26 21
Min. Gas
Consumption 14.7 13.3 11.9 19.6 18.2 14.7
Burner Injector
DMS (mm)
#44
(2.18 mm)
#55
(1.32 mm)
#56
(1.18 mm)
#40
(2.49 mm)
#53
(1.51 mm)
#55
(1.32 mm)
Pilot Injector .023 in.
(.584 mm)
.014 in.
(.356 mm)
.014 in.
(.356 mm)
.023 in.
(.584 mm)
.014 in.
(.356 mm)
.014 in.
(.356 mm)
* The allowable Outlet (Manifold) Gas Pressure ranges are: Natural Gas .80 - .95 kPA and Propane, Butane 2.37 - 2.61
kPA.
D. Gas Pressure Requirements
E. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 ft. (610 m) elevation:
Reduce input rate 4% for each 1000 ft. (305 m) above
2000 ft. (610 m).
F. Non-Combustible Materials Specication
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC (1382 °F) shall be con-
sidered non-combustible materials.
G. Combustible Materials Specication
Materials made of or surfaced with wood, compressed pa-
per, plant bers, plastics, or other material that can ignite
and burn, whether ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
H. Electrical Codes
All electrical safety testing has been done following the EN
60335-2-102 standard. Local codes apply.
C. Gas Pressure Requirements
Pressure requirements for 350X-AU, 550X-AU applianc-
es are shown in table below.
Two taps are provided on the gas control for a test gauge
connection to measure the inlet and outlet pressures.
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of the system at test pressures in
excess of 3.40 kPa.
If the appliance must be isolated from the gas supply pip-
ing system by closing an individual shut-off valve, it must
be of the handle-less type.

5
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
2 Getting Started
A. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the outside.
No additional outside air source is required.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector, re ofcials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• The vent system conguration to be used.
• Gas supply piping requirements.
• Provisions for optional heat management system.
• Electrical wiring requirements.
• Framing and nishing details.
• Whether optional accessories - devices such as a wall
switch, or remote control - are desired.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure Framing material
Pliers Hammer
Phillips screwdriver Manometer
Gloves Framing square
Voltmeter Electric drill and bits -1/4 in. (6 mm)
Plumb line Safety glasses
Level Reciprocating saw
Flat blade screwdriver
Non-corrosive leak check solution
1/2 - 3/4 in. (13 - 19 mm) length, #6 or #8 Self-drilling
screws
Caulking material (300 ºF (149 ºC) minimum continuous
exposure rating)
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualied
service technician, service agency or your dealer.
Figure 2.1 Good Faith Wall Surface Temperatures Above Appliance
B. Good Faith Wall Surface/TV Guidelines
NOTICE: Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certication. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 °F (16 °C) or
more depending on the thermometer settings and material
characteristics being measured.Use appropriate nishing
materials that are able to withstand these conditions. For
additional nishing guidelines, see Section 10.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
(152 mm)
TO CEILING
12 in.
(305 mm)
147 °F
(64 °C)
APPLIANCE FRONT
FIREPLACE
OPENING
18 in.
(457 mm)
24 in.
(610 mm)
30 in.
(762 mm)
135 °F
(57 °C)
132 °F
(56 °C)
123 °F
(51 °C)
127 °F
(53 °C)
Installation and service of this appliance should be performed
by qualified personnel. Hearth & Home Technologies
recommends HHT Factory Trained or certied professionals.

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
6
D. Inspect Appliance and Components
• Carefully remove the appliance and components from
the packaging.
• The vent system components and decorative fronts may
be shipped in separate packages.
• If packaged separately, the log set and appliance grate
must be installed.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
•Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and benet.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged, in-
complete or substitute components. Keep appliance dry.
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modication of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a re hazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under
water. Call a qualied service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.

7
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
3 Framing and Clearances
Appliance Dimensions Table
A. Appliance/Decorative Front Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Figure 3.1 Appliance Dimensions
Q
R
Ø
O
P
L
M
N
GAS LINE ACCESS
T
S
C
V
A
B
U
E
D
F
ELECTRICAL
ACCESS
G
H
J
I
K
Ø
W
Ø
HEAT-ZONE®-240V ACCESS
XX
Y
350X-AU 550X-AU
Location Inches Millimeters Inches Millimeters
A 33 838 36 914
B 28-1/8 714 31-1/8 791
C 24-1/8 613 27-3/16 691
D 16 406 18-1/16 459
E 31-1/8 791 33-1/16 840
F 3-1/2 89 3-9/16 90
G 6-7/8 175 6-7/8 175
H 21-3/8 543 23-3/8 594
I 32-3/8 822 34-3/8 873
J 34-1/2 876 36-7/16 926
K 8 203 8 203
L 8-3/4 222 8-13/16 224
M 16-1/4 413 16-5/16 414
350X-AU 550X-AU
Location Inches Millimeters Inches Millimeters
N 1/2 13 1/2 13
O 22-3/4 578 25-3/4 654
P 11-3/8 289 12-7/8 327
Q 15-7/8 403 15-7/8 403
R 6-5/8 168 6-5/8 168
S 2-1/8 54 2-3/16 56
T 6 152 6 152
U 1 25 1 25
V 28 711 30-1/16 764
W 5 127 5 127
X 14 356 14 356
Y 9-1/8 232 9-1/8 232

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
8
FIRESCREEN DECORATIVE FRONT
Figure 3.2 Decorative Front Dimensions - Firescreen and Clean Face
C
A
D
BE
F
G
A B C D E F G
550X-AU CF-32 in. 26-9/16 18-11/16 30-13/16 23-5/16 25-7/16 3-1/2 4-9/16
mm 675 475 783 592 646 89 116
CLEAN FACE DECORATIVE FRONT
A B C D E F G
350X-AU FS-3 in. 26 23 28 1-5/8 2-5/8 25-1/16 26-3/4
mm 660 584 711 41 67 637 680
550X-AU FS-5 in. 28-7/8 25-1/8 31 1-5/8 2-5/8 27-1/8 28-3/4
mm 733 638 787 41 67 689 730
A
B
FG
ED
C

9
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
B. Clearances to Combustibles
When selecting a location for the appliance it is important to
consider the required clearances to walls. See Figure 3.3.
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of trafc and away from furniture and draperies.
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 3.3 Appliance Locations
J
C
A
K
H
B
F
D
I
IF
A
E
G
L
Refer to Section 10.B for mantel and wall
projection information.
Consider the mantel or cabinet system to be
installed and comply with the necessary
requirements for elevated hearth. Refer to
instructions included with cabinet system.
Models A B C D E
Min. F G H I J K L
350X-AU
in. 39-1/2 34 55-7/8
See Section
10.B for
Alcove
Installation
1/2 44 62-1/4 16-1/4 48-1/2 68-3/4 13-1/2 7-1/2
mm 1003 864 1419 13 1118 1581 413 1232 1746 343 191
550X-AU
in. 42 37 59-1/2 1/2 44 62-1/4 16-1/4 48-1/2 68-3/4 15-1/16 7-1/2
mm 1067 940 1511 13 1118 1581 413 1232 1746 383 191
NOTICE: Additional clearance are required for Heat-Zone®-240V
installations. Provisions must be made in advance to ensure t within the
framing.

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
10
Figure 3.4 Clearances to Combustibles
E
H
I
F
G
J
MEASURE FROM TOP OF
UNIT OPENING OR FROM
TOP OF HOOD
* MINIMUM FRAMING DIMENSIONS
Models
A B C D E F G H I J
DVP Pipe SLP Pipe
Rough
Opening
(Height)
**DVP Pipe SLP Pipe
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Rough
Opening
(Depth)
Rough
Opening
(Depth)
350X-AU
in. 10 8-5/8 32-3/4 16-1/4 16-1/4 34 32 0 0 1/2 1/2 36
mm 254 219 832 413 413 864 813 0 0 13 13 914
550X-AU
in. 10 8-5/8 34-3/4 16-1/4 16-1/4 37 32 0 0 1/2 1/2 36
mm 254 219 882 413 413 940 813 0 0 13 13 914
* Adjust framing dimensions for interior sheathing (such as sheetrock)
C** Add 12 in. (305 mm) when rear venting with one 90º elbow.
C
B
D
A

11
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
C. Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should be enclosed inside the chase.
NOTICE: Treatment of ceiling restops and wall shield
restops and construction of the chase may vary with the
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
Walls, ceiling, base plate and cantilever oor of the chase
should be insulated. Vapor and air inltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air inltration may be an issue, the inside surfaces may be
sheetrocked and taped (or an equivalent method may be
used) to achieve maximum air tightness.
To further prevent drafts, the wall shield and ceiling
restops should be caulked with caulk with a minimum
of 300 ºF (149 °C) continuous exposure rating to seal
gaps. Gas line holes and other openings should be
caulked with caulk with a minimum of 300 ºF (149 °C) con-
tinuous exposure rating or stuffed with unfaced insulation. If
the appliance is being installed on a cement surface, a layer
of plywood may be placed underneath to prevent conducting
cold up into the room.
D. Floor Protection
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Maintain specied air space
clearances to appliance and vent pipe:
• Insulation and other materials must be secured to prevent
accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with appliance or chimney.
• Failure to maintain airspace may cause overheating and
a re.

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
12
A. Vent Termination Minimum Clearances
4 Termination Location and Vent Information
Fire Risk.
Maintain vent clearance to combustibles as
specied.
• DO NOT pack air space with insulation or other
materials.
Failure to keep insulation or other materials away
from vent pipe could cause overheating and re.
WARNING
Figure 4.2 Staggered Termination Caps
Gas, Wood or Fuel Oil
Termination Cap
B
Gas
Termination
Cap **
A *
*If using decorative cap cover(s), this distance may need to be
increased. Refer to the installation instructions supplied with the
decorative cap cover.
**
A B
6 in. (minimum) up to 20 in.
152 mm/508 mm
18 in. minimum
457 mm
20 in. and over 0 in. minimum
In a staggered installation with both gas and wood or fuel oil
terminations, the wood or fuel oil termination cap must be
higher than the gas termination cap.
Figure 4.1 Minimum Height From Roof To Lowest Discharge
Opening
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
VERTICAL
WALL
TERMINATION
CAP
HORIZONTAL
OVERHANG
305 mm
X
ROOF PITCH
IS X/ 305 mm
LOWEST
DISCHARGE
OPENING
510 mm MIN.
610 mm MIN.
Angle H (Min.) mm
0°-26.6° ..........................................................500*
26.6°-30.3° ..........................................................500*
30.3°-33.7° ..........................................................500*
33.7°-36.9° ..........................................................610*
36.9°-39.8° ..........................................................760*
39.8°-42.5° ..........................................................990
42.5°-45.0° ........................................................1220
45.0°-49.4° ........................................................1520
49.4°-53.1° ........................................................1830
53.1°-56.3° ........................................................2130
56.3°-59.0° ........................................................2290
59.0°-60.3° ........................................................2440
* H minimum may vary depending on regional
snowfall. Refer to local codes.

13
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
B. Chimney Diagram
Figure 4.3 Minimum Clearances for Termination
NOTES: 1. All distances are measured vertically or horizontally along the wall to a point
in line with the nearest part of the terminal.
2. Prohibited area below electricity meter or fuse box extends to ground level.
3. Flue terminal under covered area:
a) The covered area or recess shall be open on at least two sides.
b)Fanassistedueapplianceshallhaveatleastonesideopenandtheterminalshallbe
within 500 mm of the opening and discharging in the direction of the opening.
4. ClearancefromaueterminaltoaLPcylindershallbeaminimumof1meter.
MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS
OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES
T= Flue terminal M= Gas meter Shading indicates prohibited
I= Mechanical air inlet P=Electricitymeterorfusebox areasforueterminals
f
c
n
I
openable
window
j
jj
door
h
h
h
T
e e
P
T
g
k
k
db
d
M
a
c
g
See note 2
See note 3
T
a - Below eaves, balconies or other projections: MIN. CLEARANCE - in. (mm)
Appliances up to 50 MJ/h input .................................................................................... 12 (300)
Appliances over 50 MJ/h input ...............................................................................20-1/2 (500)
b - From the ground or above a balcony............................................................................... 12 (300)
c - From a return wall or external corner......................................................................... 20-1/2 (500)
d - From a gas meter (M) ...................................................................................................... 39 (1000)
e - From an electricity meter or fuse box (P)................................................................... 20-1/2 (500)
f - From a drain or soil pipe .................................................................................................... 6 (150)
g - Horizontally from any building structure (unless appliance approved
for closer installation) or obstruction facing a terminal............................................... 20-1/2 (500)
h - Fromanyotherueterminal,cowl,orcombustionairintake .................................... 20-1/2 (500)
j - Horizontally from an openable window, door, non-mechanical air
inlet, or any other opening into a building, with the exception of
sub-oorventilation:
Appliances up to 150 MJ/h input ............................................................................ 20-1/2 (500)
Appliances over 150 MJ/h input ................................................................................... 60 (1500)
k - Fromamechanicalairinlet,includingaspafan............................................................. 60 (1500)
n - Vertically below an openable window, non-mechanical air
inlet or any other opening into a building, with the exception of ...................................... See table
sub-oorventilation................................................................................................................ below
CLEARANCE
Space Heaters All other appliances
Up to 50 MJ/h input Up to 50 MJ/h input Over 50 MJ/h input and
Up to 150 MJ/h input Over 50 MJ/h input
6 in. (150 mm) 20 in. (500 mm) 39 in. (1000 mm) 59 in. (1500 mm)

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
14
C. Approved Pipe
This appliance is approved for use with Hearth & Home
Technologies DVP or SLP venting systems. Refer to Sec-
tion 12.A for vent component information and dimensions.
DO NOT mix pipe, ttings or joining methods from differ-
ent manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation. This appli-
ance requires a separate vent. DO NOT vent to a pipe
serving a separate solid fuel burning appliance.
D. Use of Elbows
Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect. See
Figure 4.4.
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A
length of straight pipe is allowed between two 45º elbows.
See Figure 4.4.
Figure 4.5 shows the vertical and horizontal offsets for
DVP or SLP elbows.
Figure 4.4
HORIZONTAL
VERTICAL
RUN
RISE
EFFECTIVE
LENGTH
DVP
Pipe
Effective Length Rise/Run
Inches Millimeters Inches Millimeters
DVP4 4 102 2-3/4 70
DVP6 6 152 4-1/4 108
DVP12 12 305 8-1/2 216
DVP24 24 610 17 432
DVP36 36 914 25-1/2 648
DVP48 48 1219 34 864
DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108
DVP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216
SLP
Pipe
Effective Length Rise/Run
Inches Millimeters Inches Millimeters
SLP4 4 102 2-3/4 70
SLP6 6 152 4-1/4 108
SLP12 12 305 8-1/2 216
SLP24 24 610 17 432
SLP36 36 914 25-1/2 648
SLP48 48 1219 34 864
SLP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108
SLP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216

15
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
Y
X
X
X
Vent Type X
Inches Millimeters
DVP 16-1/4 413
SLP 11-1/4 286
Figure 4.5 Vertical and Horizontal Offset for DVP and SLP Elbows
Vent
Type
X Y
Inches Millimeters Inches Millimeters
DVP 4-1/2 114 17 432
SLP 5 127 11-3/4 298
E. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards:
• Pipe measurements are shown using the effective length
of pipe. See Section 12.A for information on effective
length of pipe components.
• Horizontal terminations are measured to the outside
mounting surface (ange of termination cap) (see Figure
4.6).
• Vertical terminations are measured to top of last section
of pipe. See Figure 4.7.
• Horizontal pipe installed level with no rise.
MEASURE TO SHADED SURFACE
(OUTSIDE MOUNTING SURFACE)
Figure 4.6 Measure to Outside Mounting Surface
Figure 4.7. Measure to Top of Last Section of Pipe

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
16
F. Vent Diagrams
Figure 4.8 Vent Cap - Generic Appliance Shown
General Rules:
• SUBTRACT 3 ft. (914 mm) from the total H measurement
for each 90º elbow installed horizontally.
• SUBTRACT 1-1/2 ft. (457 mm) from the total H
measurement for each 45º elbow installed horizontally.
• A maximum of three 90º elbows (or six 45º elbows) may
be used in any vent conguration. Some elbows may be
installed horizontally. See Figure 4.15.
• Elbows may be placed back to back anywhere in the
system.
• Any 90º elbow may be replaced with two back to back
45º elbows.
• When penetrating a combustible wall, a wall shield
restop must be installed.
• When penetrating a combustible ceiling, a ceiling restop
must be installed.
• Horizontal runs of vent do not require vertical rise;
horizontal runs may be level.
• Horizontal termination cap should have a 1/4 in. (6
mm) downward slant to allow any moisture in cap to be
released. See Figure 4.8.
WALL
1/4 in. max.
(6 mm)
Fire Risk.
• When using SLP-HRC-SS termination cap on
top vented appliances, a one foot minimum
vertical vent section is required before installing
rst elbow.
• When using DVP-TB1 termination cap on top vented
appliances, a three foot minimum vertical vent section is
required before installing rst elbow.
WARNING

17
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
Figure 4.9
One Elbow
Top Vent - Horizontal Termination
Note: Use SLP Series
components only.
H1
V1
Note: A 6 in. (152 mm) section of straight ue
must be attached to the heater before a 90° elbow.
V1Minimum H1Maximum
Elbow only NOT ALLOWED
1 ft. 305 mm 2 ft. 610 mm
2 ft. 610 mm 4 ft. 1.22 m
3 ft. 914 mm 8 ft. 2.44 m
4 ft. 1.22 m 10 ft. 3.05 m
5 ft. 1.52 m 16 ft. 4.88 m
V1+ H1= 30 ft. (9.14 m) Maximum

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
18
Two Elbows
Top Vent - Horizontal Termination - (continued)
Figure 4.10
Note: Use SLP Series
components only.
INSTALLED
HORIZONTALLY
H1
H2
V1
V1Minimum H1+ H2Maximum
Elbow only Not allowed
6 in. 152 mm 1 ft. 305 mm
1 ft. 305 mm 2 ft. 610 mm
2 ft. 610 mm 4 ft. 1.22 m
3 ft. 914 mm 6 ft. 1.83 m
4 ft. 1.22 m 8 ft. 2.44 m
5 ft. 1.52 m 10 ft. 3.05 m
20 ft. 6.10 m 10 ft. 3.05 m
V1+ H1 + H2= 30 ft. (9.14 m) Maximum
H1 + H2= 10 ft. (3.05 m) Maximum

19
Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
Figure 4.11
Top Vent - Horizontal Termination - (continued)
Three Elbows
Note: Use SLP Series
components only.
H2
H1
V2
V1
V1Min. H1Max. V2Min. H2Max.
6 in. 152 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm
1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 2 ft. 610 mm
2 ft. 610 mm 2 ft. 610 mm 3 ft. 914 mm 4 ft. 1.22 m
3 ft. 914 mm 3 ft. 914 mm 4 ft. 1.22 m 6 ft. 1.83 m
4 ft. 1.22 m 4 ft. 1.22 m 5 ft. 1.52 m 8 ft. 2.44 m*
5 ft. 1.52 m 6 ft.* 1.83 m 6 ft. 1.83 m 6 ft. 1.83 m
*H1= 6 ft. (1.83 m) Maximum *H1+ H2= 12 ft. (3.66 m) Maximum
V1+ V2= 32 ft. (9.75 m) Maximum V1+ V2+ H1+ H2= 36 ft. (10.97 m) Maximum

Heat & Glo • 350X-AU, 550X-AU Installation Manual • 2279-980 • 12/17
20
Top Vent - Vertical Termination
No Elbow
Figure 4.12
Figure 4.13 Exhaust Restrictor Installation
V1= 36 ft. Max. (10.97 m)
RESTRICTOR
PLATE
INNER HEAT SHIELD
CENTER TAB
Note: Use SLP Series
components only.
Note: Be sure to reinstall the inner heat shield
after exhaust restrictor installation.
Exhaust restrictor Instructions
Exhaust restrictors are recommended for these verti-
cally terminated products which have excessive draft.
Exhaust restrictors will compensate for high draft, and
restore visual ame height. If the vent conguration has
a total vertical of 12 ft. (3.7 m), an exhaust restrictor may
be needed. The exhaust restrictor is located in the appli-
ance manual bag.
Note: Remove center tab in exhaust restrictor for vent
conguration with over 20 ft. (6.0 m) of vertical.
See Figure 4.13.
Note: Remove inner heat shield, if installed.
1. Install the exhaust restrictor over the center of the ex-
haust outlet in the rebox. See Figure 4.13.
2. Center the exhaust restrictor in the open end of the
exhaust outlet and secure through the slots on the ex-
haust restrictor with the two 1/4 in. self tapping screws
provided in the appliance manual bag.
3. Reinstall top refractory.
Note: If installing a vertical vent/termination off the top of the
appliance, the optional exhaust restrictor may be needed.
V1
This manual suits for next models
1
Table of contents
Other Heat & Glo Heater manuals
Popular Heater manuals by other brands

Dimplex
Dimplex CAB Series Installation and operating instructions

Manta
Manta MM438 user manual

Fondital
Fondital DIMENSION L Installation, use and maintenance manual

DeLonghi
DeLonghi TRDX4 manual

Generac Power Systems
Generac Power Systems MAC1.2G owner's manual

Econo Heat
Econo Heat ENERGY EFFICIENT user manual