Hella SINTESI Instruction Manual

Operatin
g
g
uidelines
These instructions must be read
prior to installation
and use!
Pergola SINTESI
Operating guidelines
Operatin
g
g
uidelines
Table of Contents
Preliminary remarks HELLA Pergola SINTESI.....................................................................3
General notes.......................................................................................................................4
CE marking...........................................................................................................................5
Safety instructions ................................................................................................................6
Designated use ..................................................................................................................10
Servicing, maintenance and repair .....................................................................................11
Operating guidelines...........................................................................................................13
Operatin
g
g
uidelines
Subject to technical modifications – Date of Issue
September/2023
3
Preliminary remarks HELLA
Pergola SINTESI
With this HELLA product you have opted for a high-quality product with a most up-to-date
technology that can nevertheless be easily installed and operated. In these instructions we
describe the basic installation, commissioning and use.
For authorized specialist staff
For the consumer (user)
The following symbols will assist you with the installation or use and require a safety-
conscious conduct:
Attention!
This symbol indicates instructions that, if disregarded, can put the user in
danger.
Attention!
This symbol indicates instructions that, if disregarded, can potentially
result in damage to the product.
This symbol indicates
instructions for use or
helpful information.
This symbol requires you to
act.
Attention!
This symbol indicates a risk of injury or danger to life due to an electric
shock.
This symbol indicates parts of the product, for which you will find
important information in these installation instructions.
Attention!
This symbol indicates possible risk of injury by crushing.
This symbol indicates the
cleaning of the product.
This symbol indicates the
maintenance and repair of
the product.
Operatin
g
g
uidelines
4
Subject to technical modifications – Date of Issue
September/2023
General notes
Questions
In case of questions concerning the installation or the use of your product, please consult
your authorized specialist shop.
Spare parts/repairs
Spare parts are available at your HELLA specialist shop. Only spare parts that are
approved by HELLA are allowed to be used.
Warranty/guarantee
Precondition for warranty and guarantee is a correct and regular maintenance of the sun
protection device (at least once a year).
Warranty claims are subject to statutory limitation periods. Service parts are excluded
from the warranty; the same applies for changes in color and changes in characteristics
caused by UV radiation.
Liability
In case of non-observance of the directions and information given in these instructions
and in case of improper operation or unintended use, the manufacturer shall not accept
any warranty claims concerning any damage to the product. In these cases, the liability
for consequential damage to any parts or persons is ruled out as well.
Legal notes
The graphs and texts of these instructions were carefully prepared. We cannot be held
liable for any errors and their potential consequences! Subject to technical modifications
to the product and to these instructions! These instructions include copyrighted
information. All rights reserved! The listed product or brand names are trademarks of the
respective owners.
Installation Instructions
Detailed instructions for installing the product are available in the download section at
https://www.hella.info.

Operatin
g
g
uidelines
Subject to technical modifications – Date of Issue
September/2023
5
CE marking
The HELLA Pergola SINTESI and SINTESI FREE are in compliance with the declaration of
performance according to the Construction Products Regulation; if the unit is operated with
a motor drive it is additionally in compliance with the Machinery Directive and the Guideline
for Electromagnetic Compatibility; in case of proper use, the front-mounted blind
corresponds to the basic requirements of the harmonised standard EN 13561. The
respective declarations are deposited with the manufacturers.
The CE identification applies for the delivery status of the product. Specifications regarding
the wind resistance in the installed condition are given in the product documentation. The
product mounted meets the requirements of the specified standard only, if
during installation the information and instructions given in these instructions as well
as the information and instructions of the manufacturers of the screws have been
observed,
the product is installed with the recommended type and number of fasteners /
screws.
No changes, rebuildings or extensions, with the exception of those described in these
instructions, are allowed with this product. The fixed CE-label expires with any change,
rebuilding or extension.
HELLA Sonnen- und Wetterschutztechnik GmbH
A-9913 Abfaltersbach, Nr. 125
18
LE-PERG-01-002
EN 13561:2004+A1:2008
Pergola
SINTESI, SINTESI FREE
Exterior shading
Wind resistance class 3
Operatin
g
g
uidelines
6
Subject to technical modifications – Date of Issue
September/2023
Safety instructions
These installation instructions refer to prefabricated elements, that (1) for
100% are made from parts, which are defined by us, and (2) which are
made in manufacturing processes, which are defined by us too; in all other
cases we do not provide any guarantee!
The safety instructions as well as the appropriate instructions must be read
carefully before installation and use. In case of non-observance of the
directions and information given in these instructions and in case of
improper installation and operation or unintended use, the manufacturer
shall not accept any warranty claims concerning any damage to the
product. In these cases, the liability for consequential damage to any parts
or persons is ruled out as well.
- Follow the described installation steps and pay attention to
recommendations and notes.
- Keep these instructions in a safe place.
- All installation and removal works, as well as maintenance and repair
works are only allowed to be carried out by authorised and qualified
specialist staff.
- If switching, automatic or radio control devices are used to operate the
units, the information given in the enclosed instructions of the
manufacturer must be observed.
- During operation do not put your hand into or touch movable parts.
- Ensure that clothing or body parts cannot get caught on the unit.
- Observe the regulations for prevention of accidents of the employer's
liability insurance association!
- Before operation check the unit for visible damage. If the unit is
damaged, it should not be used; please consult authorized specialist
staff immediately.
- Risk of injury and accident due to the weight of the product!
- Take safety measures against the danger of squashing, especially when
operating the unit with automatic devices.
- Place the operating switch within sight of the unit, but not near any of the
moving parts.
- Never let children play with the unit.
Operatin
g
g
uidelines
Subject to technical modifications – Date of Issue
September/2023
7
Safety instructions
Danger due to crushing!
- Keep people away from the product while it is moving.
- Do not reach between moving parts while the product is in motion.
- Do not allow children to play with operating elements such as the hand-
held radio transmitter or switches of the product (keep the hand-held
radio transmitter out of reach of children’s hand!).
- Products that are operated via a control system can start moving at any
time and without prior notice. Inform people and children who are in the
vicinity of the product of the dangers so that the danger can be
eliminated.
This symbol is attached to the front of the front rail and indicates a possible
crushing hazard.
Danger of suffocation!
Ensure that the foil cannot get into the hands of children. Keep the foil in a
safe place.
Operatin
g
g
uidelines
8
Subject to technical modifications – Date of Issue
September/2023
Safety instructions
Attention! Risk of injury or danger to life due to an electric shock!
- Set-up, examination, commissioning and error correction of the unit must
only be performed by authorised or trained expert staff (as per VDE
0100).
- Switch off the current to the connecting lines when working at the unit.
There is danger to life! Take safety precautions against unintentional
switching on!
- Check the electrical wires regularly for damage. Do not use the unit if
any damage is found.
- Our electrically driven units are in accordance with the regulations for
power plants acc. to VDE 0100. We cannot guarantee for the operational
reliability of the unit with non-approved modifications.
- White motor cables are not UV-resistant and must therefore be routed in
empty conduits, cable ducts, or similar.
- The enclosed installation instructions of the electrical devices supplied
must be observed.
Units with motor drive:
The drives used are operated with a voltage of AC 230V/50Hz. Please
check the power supply provided by your utility company before connecting.
Any other voltage can destroy the drives.
Winter operation/Operation by frost:
Snow or ice can destroy the unit.
The units may only be operated if no ice or snow is lying on the cover of
SINTESI and TERRA SIDE.
The SINTESI and TERRA SIDE covers must be retracted at temperatures
below freezing point/in the event of frost, as the covers and their
mechanisms in the guide rails may get damaged.
During this time automatic control devices must be switched to
manual operation.

Operatin
g
g
uidelines
Subject to technical modifications – Date of Issue
September/2023
9
Safety instructions
Using the product for the wrong purpose:
Use the unit solely for the given purpose. Any wrong use can endanger the
user and result in damage to the product. Do not load the product with
additional weights. If the product is used for a different purpose, the right to
claim under guarantee is forfeited.
Operation of the unit in case of storm
To prevent damage, please retract your sun protection device with snowfall
or wind. If automatic control devices are used, adjust the wind controller in
dependance upon the wind resistance class of your sun protection device.
- Please make sure that no obstacles block the guide rails of the unit.
- Do not manually displace the movable parts of the unit.
- Especially in case of heavy rain or blocked drains, the water drain via the
integrated pipes is not possible completely; therefore a part of the water
must be discharged via the rain gutter.
- Plants and falling leaves can contain acids, which may cause damage to
the cover. Encrustations or damage to the cover resulting therefrom are
excluded from the warranty.
Operatin
g
g
uidelines
10
Subject to technical modifications – Date of Issue
September/2023
Designated use
Sun protection
Rain shelter (adequate inclination provided)
pplicationa recommendation - wind force
Wind force according to Beaufort Up to a complete width of [mm]
10 (up to 102 km/h or 28.4 m/s) 4000
9 (up to 88 km/h or 24.4 m/s) 5000
8 (up to 74 km/h or 20.7 m/s) 6000
The specifications given refer to the pergola SINTESI with two columns, completely
extended cover and without lateral end caps.
Minimum inclination angle of the unit to be used as rain shelter
Operatin
g
g
uidelines
Subject to technical modifications – Date of Issue
September/2023
11
Servicing, maintenance and repair
An unintentional switching on of units with motor drive is possible. Make
sure that the automatic control device is switched off and that the current
supply is interrupted during cleaning or maintenance work. If the unit is
operated manually, the operating crank handle must be unhooked and
kept in a safe place.
Cleaning
As a sun protection device fixed outside, the unit can get dirty in the
course of time. This will not reduce the usability of your unit. The powder-
coated parts of your unit will remain presentable for longer, if they are
cleaned regularly with a soft woollen cloth.
Do not use solvents, alcohol (rubbing alcohol) or scouring cleansing
agents! Use a mild household cleaner and a soft cloth to wash down
fingerprints and light grease- or oil patches. Rinse off with clear water
and dry with a soft cloth.
Never use a high-pressure cleaner. There is a risk that the surface of the
aluminium parts and the cover are affected by the pressure and the heat.
Remove regularly dirt or objects
- from the guide rails of the TERRA SIDE,
- from the rain gutter and the water entry openings facing towards the
column,
- from the water discharge openings at the bottom of the column,
Operatin
g
g
uidelines
12
Subject to technical modifications – Date of Issue
September/2023
Servicing, maintenance and repair
Maintenance
All inspection and maintenance works must be carried out by a
specialised company from HELLA or a HELLA partner. Regularly check
the electrical wires of motor driven units for damage. Check the
mechanical parts of your unit for visible damage. After exceptional events
such as storm, hail, sleet, maloperation or the like, the unit must be
checked for noticeable damage prior to operating it. If the unit is
damaged, it must not be used; consult authorized specialist staff
immediately. It is recommended to have the unit maintained by specialist
staff on an annual basis. This way wear is detected at an early stage and
damage to the unit is prevented.
Repair:
Improper repair works may cause both risk of injury to persons or
damage to the units.
Repair works must be carried out by a HELLA specialist company or a
partner company of HELLA.
Only use original spare parts from HELLA.

Operatin
g
g
uidelines
Subject to technical modifications – Date of Issue
September/2023
13
Operating guidelines
SINTESI
Motor drive
The fabric of the unit is retracted and extended via a radio transmitter or an
automatic device.
Operating the unit with ONYX:
For information regarding the operation and programming of the unit and
details on sensors see chapter “Operating and configuring Pergola PLUS
with ONYX”.
Operating the unit with Somfy io:
For information regarding the operation and programming of the unit see
the provided documentation by the manufacturer. For details on additional
sensors see chapter “Sensors Somfy io”.
Automatic control devices may fail under extreme conditions (e.g. power
failure or technical faults).
Thermal protection:
The drives used are not suitable for a non-stop operation. The integrated
thermal protection switches the drive off after approx. 4 minutes. After
approx. 10 to 15 minutes, the drive is ready for use again.
Lighting
By activating a radio transmitter or an automatic device you can switch the
lighting on or off.
Controlling the lightning with ONYX:
Operation and programming are to be found in the chapter "Operation and
configuration of Pergola PLUS with ONYX"
Operatin
g
g
uidelines
14
Subject to technical modifications – Date of Issue
September/2023
Operating guidelines
Hand-held radio transmitter with scroll wheel
Setting the scroll wheel function with hand-held radio transmitter “Somfy
Situo 5 Variation A/M io”:
- Open the rear housing cover
- Set the selector switch for the operating mode “E” to position 2
In this way the scroll wheel reacts to the LED lighting and heating. You will
find detailed information in the enclosed instructions of the manufacturer.
2
E
Operatin
g
g
uidelines
Subject to technical modifications – Date of Issue
September/2023
15
Operating guidelines
TERRA SIDE
Motor drive:
By operating a hand-held radio transmitter or an
automatic device, the cover moves up or down.
Operating the unit with ONYX:
For information regarding the operation and
programming of the unit and details on sensors
see chapter “Operating and configuring Pergola
PLUS with ONYX”.
Operating the unit with Somfy io:
For information regarding the operation and
programming of the unit see the provided
documentation by the manufacturer. For details
on additional sensors see chapter “Sensors
Somfy io”.
The end positions of the drive are not adjusted ex works.
Please refer to the chapter “Setting the motor” for more details.
Automatic control devices may fail under extreme conditions (e.g. power
failure or technical faults).
Operatin
g
g
uidelines
16
Subject to technical modifications – Date of Issue
September/2023
Operating guidelines
TERRA SIDE
Automatic control devices should be set to
manual operation during your absence.
Adjust the external control device in such a
way, that a non-stop operation of the motor is
avoided!
Thermal protection:
The drives used are not suitable for a non-stop
operation. The integrated thermal protection
switches the drive off after approx. 4 minutes.
After approx. 10 to 15 minutes, the drive is
ready for use again.
Please avoid to roll up the cover opposite to
the intended direction (see adjacent
illustration).
This may cause damage to the cover.

Operatin
g
g
uidelines
HELLA Interior Venetian
Blinds
regulate the lighting in a
room very comfortably,
immediately gracing it
with much more
atmosphere.
HELLA Insect screens
and you decide who is
allowed to come in and
who isn't.
HELLA Pleated Blind
folds up very compactly
and protects very well
against the sun and nosey
glances where only little
space is available.
HELLA Outdoor Blinds
serve for the light
regulation, as view
protection, anti-glare blind
and heat protection.
HELLA Front-mounted
Roller Shutter
for more safety and
protection against rain,
wind, heat, the cold, noise,
incident light and nosey
glances, also available for
subsequent installation.
HELLA Vertical awning
With toggle catch
mechanism for a lovely
façade design with perfect
heat and glare protection.
For questions, wishes and ideas:
HELLA Infoline +43/(0)4846/6555-0
HELLA Sonnen- und Wetterschutztechnik GmbH
A-9913 Abfaltersbach, No. 125
Phone: +43/(0)4846/6555-0
Fax: +43/(0)4846/6555-134
e-mail: office@hella.info
Internet: http://www.hella.info
Table of contents
Other Hella Lawn And Garden Equipment manuals