Installation Instructions
a. When installing these units, it is important to comply with the most recently established
rules and regulations as deemed pertinent by the local and national electrical, gas, ventilation,
sanitation, and fire codes. These units are classified by Underwriters Laboratories, Inc. as
Gas-Fired Food Service Equipment in accordance with American National Standards Institute
ANSI Z83.11b-1991, Gas Food Service Equipment - Ranges and Unit Boilers.
b. These gas units may not be directly connected to a gas flue or exhaust. However, the
units may only be operated in conjunction with a canopy type exhaust hood.
c. The room where the units are being installed must be ventilated in accordance to the
valid codes and regulations.
d. The units are to be installed securely and horizontally. The units may be installed on
combustible floors.
e. The minimum clearance to the rear or side walls must be 3 inches. It is also important
to insure that the bottom of the units is kept clear so that proper ventilation or air exchange can
occur.
f. Normally, the units will be sent to the operator already set up for the particular type of
gas available at their location. However, unless otherwise specified, the units will be set up for
natural gas use. Before installing and using the units for the first time, it is important to make
sure that the gas type and pressure indicated on the data plate matches the type of gas avail-
able in the location. Should this not be the case, it is imperative to change or convert the units
to the needed gas type.
g. The units must be fitted with the manual shut-off gas cock (valve) supplied with the
machine. This manual valve is needed to shut off the gas to the machine during maintenance
work, repairs, pressure testing and if the unit needs to be disconnected for any reason. DO
NOT REMOVE otherwise warranty will be voided.
h. A gas regulator is also supplied with the machine. This component is needed so that
the appropriate gas pressure can be set and insure an optimum operation of the unit. DO
NOT REMOVE otherwise warranty will be voided.
i. When installing this unit with a gas quick disconnect, a tethering device must be used.
j. Depending on local codes or if deemed necessary, a gas filter may also be required.
k. Do connect the unit to a 3/4" gas line. Connecting the unit to a lesser line can reduce
the units effectiveness or cause improper operation.