hilscher NPIX Series Operating and installation instructions

Device description
netPI Extension Modules
NPIX
Hilscher Gesellschaft für Systemautomation mbH
www.hilscher.com
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public

Table of contents 2/35
Table of contents
1 Introduction .............................................................................................................................. 3
1.1 About this document ........................................................................................................3
1.1.1 Description of the contents ............................................................................... 3
1.1.2 List of revisions ................................................................................................. 3
1.1.3 Conventions in this document........................................................................... 4
1.2 Legal notes.......................................................................................................................5
2 Installation ................................................................................................................................ 9
2.1 Installing NPIX (standard procedure) ...............................................................................9
2.2 Installing NPIX with open netPI casing ..........................................................................12
3 Pinning of the extension socket........................................................................................... 18
4 NIOT-E-NPIX-RS485: Extension module for RS-485........................................................... 19
5 NIOT-E-NPIX-RS232: Extension module for RS-232........................................................... 22
6 NIOT-E-NPIX-IO: Extension module for digital inputs and outputs .................................. 25
7 NIOT-E-NPIX-EVA: Evaluation module ................................................................................ 30
Contacts.................................................................................................................................. 35
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Introduction 3/35
1 Introduction
1.1 About this document
1.1.1 Description of the contents
This document describes the hardware and the installation of the netPI
Extension Modules:
·NIOT-E-NPIX-RS485 (RS-485 communication interface)
Part no.: 1322.011
·NIOT-E-NPIX-RS232 (RS-232 communication interface)
Part no.: 1322.012
·NIOT-E-NPIX-IO (communication interface for digital inputs and
outputs)
Part no.: 1322.040
·NIOT-E-NPIX-EVA (evaluation board)
Part no.: 1322.050
1.1.2 List of revisions
Revision Date Revision
1 01-23-2017 Document created
Table1: List of revisions
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Introduction 4/35
1.1.3 Conventions in this document
Notes, operation instructions and results of operation steps are marked as
follows:
Notes
Important:
<important note>
Note:
<simple note>
<note, where to find further information>
Operation instructions
1. <operational step>
Ø<instruction>
Ø<instruction>
2. <operational step>
Ø<instruction>
Ø<instruction>
Results
<intermediate result>
<final result>
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Introduction 5/35
1.2 Legal notes
Copyright
© Hilscher Gesellschaft für Systemautomation mbH
All rights reserved.
The images, photographs and texts in the accompanying materials (in the
form of a user's manual, operator's manual, Statement of Work document
and all other document types, support texts, documentation, etc.) are
protected by German and international copyright and by international trade
and protective provisions. Without the prior written consent, you do not
have permission to duplicate them either in full or in part using technical or
mechanical methods (print, photocopy or any other method), to edit them
using electronic systems or to transfer them. You are not permitted to make
changes to copyright notices, markings, trademarks or ownership
declarations. Illustrations are provided without taking the patent situation
into account. Any company names and product designations provided in
this document may be brands or trademarks by the corresponding owner
and may be protected under trademark, brand or patent law. Any form of
further use shall require the express consent from the relevant owner of the
rights.
Important notes
Utmost care was/is given in the preparation of the documentation at hand
consisting of a user's manual, operating manual and any other document
type and accompanying texts. However, errors cannot be ruled out.
Therefore, we cannot assume any guarantee or legal responsibility for
erroneous information or liability of any kind. You are hereby made aware
that descriptions found in the user's manual, the accompanying texts and
the documentation neither represent a guarantee nor any indication on
proper use as stipulated in the agreement or a promised attribute. It cannot
be ruled out that the user's manual, the accompanying texts and the
documentation do not completely match the described attributes, standards
or any other data for the delivered product. A warranty or guarantee with
respect to the correctness or accuracy of the information is not assumed.
We reserve the right to modify our products and the specifications for such
as well as the corresponding documentation in the form of a user's manual,
operating manual and/or any other document types and accompanying
texts at any time and without notice without being required to notify of said
modification. Changes shall be taken into account in future manuals and do
not represent an obligation of any kind, in particular there shall be no right
to have delivered documents revised. The manual delivered with the
product shall apply.
Under no circumstances shall Hilscher Gesellschaft für Systemautomation
mbH be liable for direct, indirect, ancillary or subsequent damage, or for
any loss of income, which may arise after use of the information contained
herein.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Introduction 6/35
Liability disclaimer
The hardware and/or software was created and tested by Hilscher
Gesellschaft für Systemautomation mbH with utmost care and is made
available as is. No warranty can be assumed for the performance or
flawlessness of the hardware and/or software under all application
conditions and scenarios and the work results achieved by the user when
using the hardware and/or software. Liability for any damage that may have
occurred as a result of using the hardware and/or software or the
corresponding documents shall be limited to an event involving willful intent
or a grossly negligent violation of a fundamental contractual obligation.
However, the right to assert damages due to a violation of a fundamental
contractual obligation shall be limited to contract-typical foreseeable
damage.
It is hereby expressly agreed upon in particular that any use or utilization of
the hardware and/or software in connection with
·Flight control systems in aviation and aerospace;
·Nuclear fusion processes in nuclear power plants;
·Medical devices used for life support and
·Vehicle control systems used in passenger transport
shall be excluded. Use of the hardware and/or software in any of the
following areas is strictly prohibited:
·For military purposes or in weaponry;
·For designing, engineering, maintaining or operating nuclear systems;
·In flight safety systems, aviation and flight telecommunications systems;
·In life-support systems;
·In systems in which any malfunction in the hardware and/or software
may result in physical injuries or fatalities.
You are hereby made aware that the hardware and/or software was not
created for use in hazardous environments, which require fail-safe control
mechanisms. Use of the hardware and/or software in this kind of
environment shall be at your own risk; any liability for damage or loss due
to impermissible use shall be excluded.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Introduction 7/35
Warranty
Hilscher Gesellschaft für Systemautomation mbH hereby guarantees that
the software shall run without errors in accordance with the requirements
listed in the specifications and that there were no defects on the date of
acceptance. The warranty period shall be 12 months commencing as of the
date of acceptance or purchase (with express declaration or implied, by
customer's conclusive behavior, e.g. putting into operation permanently).
The warranty obligation for equipment (hardware) we produce is 36
months, calculated as of the date of delivery ex works. The aforementioned
provisions shall not apply if longer warranty periods are mandatory by law
pursuant to Section 438 (1.2) BGB, Section 479 (1) BGB and Section 634a
(1) BGB [Bürgerliches Gesetzbuch; German Civil Code] If, despite of all
due care taken, the delivered product should have a defect, which already
existed at the time of the transfer of risk, it shall be at our discretion to
either repair the product or to deliver a replacement product, subject to
timely notification of defect.
The warranty obligation shall not apply if the notification of defect is not
asserted promptly, if the purchaser or third party has tampered with the
products, if the defect is the result of natural wear, was caused by
unfavorable operating conditions or is due to violations against our
operating regulations or against rules of good electrical engineering
practice, or if our request to return the defective object is not promptly
complied with.
Costs of support, maintenance, customization and product care
Please be advised that any subsequent improvement shall only be free of
charge if a defect is found. Any form of technical support, maintenance and
customization is not a warranty service, but instead shall be charged extra.
Additional guarantees
Although the hardware and software was developed and tested in-depth
with greatest care, Hilscher Gesellschaft für Systemautomation mbH shall
not assume any guarantee for the suitability thereof for any purpose that
was not confirmed in writing. No guarantee can be granted whereby the
hardware and software satisfies your requirements, or the use of the
hardware and/or software is uninterruptable or the hardware and/or
software is fault-free.
It cannot be guaranteed that patents and/or ownership privileges have not
been infringed upon or violated or that the products are free from third-party
influence. No additional guarantees or promises shall be made as to
whether the product is market current, free from deficiency in title, or can be
integrated or is usable for specific purposes, unless such guarantees or
promises are required under existing law and cannot be restricted.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Introduction 8/35
Confidentiality
The customer hereby expressly acknowledges that this document contains
trade secrets, information protected by copyright and other patent and
ownership privileges as well as any related rights of Hilscher Gesellschaft
für Systemautomation mbH. The customer agrees to treat as confidential all
of the information made available to customer by Hilscher Gesellschaft für
Systemautomation mbH and rights, which were disclosed by Hilscher
Gesellschaft für Systemautomation mbH and that were made accessible as
well as the terms and conditions of this agreement itself.
The parties hereby agree to one another that the information that each
party receives from the other party respectively is and shall remain the
intellectual property of said other party, unless provided for otherwise in a
contractual agreement.
The customer must not allow any third party to become knowledgeable of
this expertise and shall only provide knowledge thereof to authorized users
as appropriate and necessary. Companies associated with the customer
shall not be deemed third parties. The customer must obligate authorized
users to confidentiality. The customer should only use the confidential
information in connection with the performances specified in this
agreement.
The customer must not use this confidential information to his own
advantage or for his own purposes or rather to the advantage or for the
purpose of a third party, nor must it be used for commercial purposes and
this confidential information must only be used to the extent provided for in
this agreement or otherwise to the extent as expressly authorized by the
disclosing party in written form. The customer has the right, subject to the
obligation to confidentiality, to disclose the terms and conditions of this
agreement directly to his legal and financial consultants as would be
required for the customer's normal business operation.
Export provisions
The delivered product (including technical data) is subject to the legal
export and/or import laws as well as any associated regulations of various
countries, especially such laws applicable in Germany and in the United
States. The products / hardware / software must not be exported into such
countries for which export is prohibited under US American export control
laws and its supplementary provisions. You hereby agree to strictly follow
the regulations and to yourself be responsible for observing them. You are
hereby made aware that you may be required to obtain governmental
approval to export, reexport or import the product.
Terms and conditions
Please read the notes about additional legal aspects on our netIOT web
site under http://www.netiot.com/netiot/netiot-edge/terms-and-
conditions/.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 9/35
2 Installation
2.1 Installing NPIX (standard procedure)
This section describes how to install the NPIX Extension Module in the
netPI.
Requirements
Electrostatically sensitive devices
When installing the NPIX Extension Module: Take the necessary
precautions for handling components that are vulnerable to electrostatic
discharge.
ØTake care to touch the NPIX Extension Module only at its casing or
front panel. Do not touch the metal contacts on the PCB.
ØBefore installation, touch a grounded object to discharge potential
static.
ØWear an approved grounding wrist strap.
ØIf available, use a static-safe workstation.
·If your netPI has already been installed in a switch cabinet, remove the
device from the top hat rail and disconnect all cables from the device.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 10/35
Step-by-step instructions
ØRemove the screws of the cover of the extension slot at the bottom of
the netPI.
Figure1: Remove cover of extension slot
Figure2: Extension slot with cover removed
ØInsert the NPIX module into the extension slot. Take care to fit the
guiding rail/slit at the upper module cover correctly into the guiding pin
of the extension slot.
Figure3: Inserting module
ØPush the module into the slot until it reaches its final position.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 11/35
ØTighten the screws at the module.
Note:
If you have difficulties to tighten the screws, this may be due to the
module being slightly tilted and the connector pins thus not fitting
properly into the extension socket of the netPI. In this case, it can
be useful to open the casing of the netPI and to proceed as
described in section Installing NPIX with open netPI
casing [}page12].
Figure4: Tighten screws of the extension module
ØStick the label (included in the delivery of the module) onto the casing of
the netPI.
Figure5: Attach label sideways
ðYou have installed the NPIX Extension Module.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 12/35
2.2 Installing NPIX with open netPI casing
This section describes how to install the NPIX Extension Module in the
netPI with the upper casing of the netPI removed. The installation with an
opened casing allows you free sight of the expansion socket inside the
netPI, thus enabling you to check whether you have fitted the connector
pins of the module properly into the expansion socket.
Requirements
Electrostatically sensitive devices
When installing the NPIX Extension Module: Take the necessary
precautions for handling components that are vulnerable to electrostatic
discharge.
ØTake care to touch the netPI and NPIX Extension Module only at their
casings respectively front panels. Do not touch the metal contacts on
the PCBs.
ØBefore installation, touch a grounded object to discharge potential
static.
ØWear an approved grounding wrist strap.
ØIf available, use a static-safe workstation.
·If your netPI has already been installed in a switch cabinet, remove the
device from the top hat rail and disconnect all cables from the device.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 13/35
Step-by-step instructions
ØRemove the screws of the cover of the extension slot at the bottom of
the netPI.
Figure6: Remove cover of extension slot
Figure7: Extension slot with cover removed
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 14/35
The casing of the netPI is held together by six screws.
ØRemove the screws:
Figure8: Screws on the top side
Figure9: Screws on the lower side
ØRemove the upper casing by sliding it from the netPI device in the
direction of the antenna. Take care not to damage the antenna.
Figure10: Remove casing
ÊYou now have free sight of the expansion socket on the netPI PCB.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 15/35
ØInsert the NPIX module into the extension slot. Take care to fit the
guiding rail/slit at the upper module cover correctly into the guiding pin
of the extension slot.
Figure11: Inserting module
ØPush the module into the slot until it reaches its final position.
Figure12: Connector pins correctly fitted to the extension slot
Take care to insert the module horizontally. If the module is tilted
downwards, the connector pins of the module might jam at the lower part of
the extension socket.
Figure13: Connector pins jammed
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 16/35
ØTighten the screws at the NPIX Extension Module.
Figure14: Tighten screws at the module
ØPut the protection cap on the antenna, as shown in the picture below:
Figure15: Protection cap on antenna
ØSlide the upper casing back onto the netPI device.
Figure16: Refit casing
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Installation 17/35
ØFix casing with the screws.
Figure17: Tighten screws
ØStick the label (included in the delivery of the module) onto the casing of
the netPI.
Figure18: Attach label sideways
ðYou have installed the NPIX Extension Module.
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

Pinning of the extension socket 18/35
3 Pinning of the extension socket
The following table shows the pinning of the extension socket inside the
netPI.
Note:
Please note that the extension socket mechanically resembles the
Mini PCI Express format, but is - due to its proprietary pinning - in
electric respect not a "real" Mini PCIe interface.
Socket Pin Signal Pin Signal
1 +24V DC 27 MMIO17
2 +24V DC 28 BCM 3 (BCM_SCL1)
3 +24V DC 29 MMIO18
4 +24V DC 30 BCM 4 (GPIO)
5 Isolation Zone 31 MMIO19
6 Isolation Zone 32 BCM 7(BCM_SPI0_CE1_N)
7 GND 33 MMIO20
8 GND 34 BCM 18 (BCM_SPI1_CE0_N)
9 GND 35 MMIO21
10 GND 36 BCM 22 (GPIO)
11 ID_SD (BCM 0) 37 MMIO22
12 ID_SC (BCM 1) 38 BCM 23 (GPIO)
13 +3V3 39 MMIO23
14 +3V3 40 BCM 25 (GPIO)
15 +5V 41 MMIO24
16 +5V 42 BCM 27 (GPIO)
17 MMIO08 43 MMIO25
18 RSTOUT_NETRAPID
(from communication
CPU)
44 BCM 16 (BCM_SPI1_CS2_N)
19 MMIO09 45 MMIO26
20 BCM14 (BCM_TXD0) 46 BCM 19 (BCM_SPI1_MISO)
21 MMIO10 47 MMIO27
22 BCM 15 (BCM_RXD0) 48 BCM 20 (BCM_SPI1_MOSI)
23 MMIO11 49 MMIO36
24 BCM 17 (BCM_TX_EN) 50 BCM 21 (BCM_SPI1_SCLK)
25 MMIO16 51 GND
26 BCM 2 (BCM_SDA1) 52 BCM 26 (GPIO) (IRQ from NPIX)
Table2: Pinning of the extension socket in netPI
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

NIOT-E-NPIX-RS485: Extension module for RS-485 19/35
4 NIOT-E-NPIX-RS485: Extension module for RS-485
Functional description
The NIOT-E-NPIX-RS485 is an extension module with RS-485 interface.
Figure19: NIOT-E-NPIX-RS485
Technical data
Parameter Value
Part number 1322.011
Interface RS-485
Connector D-Sub, 9-pole, female
Isolation Yes
LEDs COM0: Communication state (Duo LED red/green)
COM1: Communication state (Duo LED red/green)
Table3: Technical data NIOT-E-NPIX-RS485
Label
The label is included in the delivery as a separate sticker, and is to be
attached to the casing of the netPI next to the mounted module.
Figure20: NIOT-E-NPIX-RS485 Label
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018

NIOT-E-NPIX-RS485: Extension module for RS-485 20/35
Pinning of the RS-485 connector
Pin Signal Description
1 n.c. Not connected
2 n.c. Not connected
3 RXD/TXD-P Receive/transmit data positive
4 n.c. Not connected
5 ISOGND Ground (isolated)
6 VP Power supply positive +5V for terminating resistor, maximum
current 15 mA
7 n.c. Not connected
8 RXD/TXD-N Receive/transmit data negative
9 n.c. Not connected
D-Sub socket connected to PE
Table4: RS-485 interface
Pinning of the host interface
Connector Pin Signal Description Pin Signal Description
1 n.c. Not connected 27 n.c. Not connected
2 n.c. Not connected 28 n.c. Not connected
3 n.c. Not connected 29 n.c. Not connected
4 n.c. Not connected 30 n.c. Not connected
5 n.c. Not connected 31 n.c. Not connected
6 n.c. Not connected 32 n.c. Not connected
7 GND Reference potential 33 n.c. Not connected
8 GND Reference potential 34 n.c. Not connected
9 GND Reference potential 35 n.c. Not connected
10 GND Reference potential 36 BCM22(GPIO) -
11 ID_SD (BCM0) - 37 n.c. Not connected
12 ID_SC (BCM1) - 38 BCM23(GPIO) -
13 +3V3 - 39 n.c. Not connected
14 +3V3 - 40 BCM25(GPIO) -
15 n.c. Not connected 41 n.c. Not connected
16 n.c. Not connected 42 n.c. Not connected
17 n.c. Not connected 43 n.c. Not connected
18 n.c. Not connected 44 n.c. Not connected
19 n.c. Not connected 45 n.c. Not connected
20 BCM14(BCM_TXD0) - 46 n.c. Not connected
21 n.c. Not connected 47 n.c. Not connected
22 BCM15(BCM_RXD0) - 48 n.c. Not connected
23 n.c. Not connected 49 n.c. Not connected
24 BCM17(BCM_TX_EN) - 50 n.c. Not connected
25 n.c. Not connected 51 GND Reference
potential
26 n.c. Not connected 52 BCM26(GPIO) -
Table5: Pinning of the host interface of NIOT-E-NPIX-RS485
netPI Extension Modules | NPIX
DOC171201HW01EN | Revision 1 | English | 2018-01 | Released | Public
© Hilscher 2018
This manual suits for next models
4
Table of contents
Other hilscher Control Unit manuals
Popular Control Unit manuals by other brands

Sentiotec
Sentiotec Pro-C2 Instructions for installation and use

Rasmussen
Rasmussen SPK3E owner's manual

Honeywell
Honeywell Silent Knight SK-Relay-6 Installation and maintenance instructions

Keysight Technologies
Keysight Technologies 34952A user guide

Digi
Digi XTend vB DigiMesh XTP9B-DPM-001 user guide

TA Hydronics
TA Hydronics STAF-SG Series manual

Aion Electronics
Aion Electronics Comet Distortion manual

Siemens
Siemens SIMATIC 505 Installation and operation guide

Geist
Geist Watchdog Wi instruction manual

HMS
HMS IXXAT Safe T100 Safety Manual–Original Instructions

BENKISER
BENKISER 828er quick start guide

Burkert
Burkert 2100 series operating instructions