Hirose GT21B User manual

GT21B
Terminal Instruction Manual
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
0
TITLE
GT21B Terminal Instruction Manual
APPROVED
KI.HIROKAWA
20210701
CHECKED
MH.YAMAGUCHI
20210701
DESIGNED
HK.WATANABE
20210701
WRITTEN
HK.WATANABE
20210701
TECHICAL SPECIFICATION
ETAD-T0685-01
0
1/ 8
FORM HC0011-9-1
HIROSE ELECTRIC CO.,LTD.
△
△
Jan.1.2022Copyright2022HIROSEELECTRICCO.,LTD.AllRightsReserved.

HIROSE ELECTRIC CO.,LTD.
ETAD-T0685-01
0
2/ 8
FORM HC0011-9-2
△
1.Configuration
GT21B-2426/1.6-2.9SCF Female terminal
GT21B-2426/1.6-2.9PCF Male terminal
Shield barrel
Insulation Barrel
Insulation Barrel
Shield barrel
Wire barrel
Carrier
Wire barrel
Carrier
Jan.1.2022Copyright2022HIROSEELECTRICCO.,LTD.AllRightsReserved.

HIROSE ELECTRIC CO.,LTD.
ETAD-T0685-01
0
3/ 8
FORM HC0011-9-2
△
2.Crimping procedure
(1) Stripping the cable
The stripping specification and the cable cut dimensions after crimping are shown below.
Cable cut dimensions (GT21B-2426/1.6-2.9SCF + S type housing)
GT21T-1S-HU (GT21-1S-HU(*))
Cable cut dimensions (GT21B-2426/1.6-2.9PCF + P type housing)
GT21N-1PP-HU(*)
Note) The dimensions of the stripping specification are recommended values. In order to satisfy
the quality of crimping, please verify the crimp quality standard.
Jan.1.2022Copyright2022HIROSEELECTRICCO.,LTD.AllRightsReserved.

HIROSE ELECTRIC CO.,LTD.
ETAD-T0685-01
0
4/ 8
FORM HC0011-9-2
△
(2)Crimping
①Use our company’s applicator for crimping
②Inspection before cimping
・Before crimping, verify if any foreign matter is on the crimper and the anvil. If so, clear
it away.
・When setting up the terminal, verify there is no interference between the terminal and
the terminal plate (Picture1). (In case of interference, the terminal cannot be set up
correctly.)
・Verify the crimping data of the appropriate cable and, measure the C/H as shown on the
cross-section below.
When crimping, set the stripped coaxial cable by making the contact with the wire barrel and the
dielectric of the cable, as shown in the Picture1.
Picture1 Cable position at the crimping
【Reference for the position of the cable】
Wire barrel
Terminal plate
Jan.1.2022Copyright2022HIROSEELECTRICCO.,LTD.AllRightsReserved.

HIROSE ELECTRIC CO.,LTD.
ETAD-T0685-01
0
5/ 8
FORM HC0011-9-2
△
Appearance after crimping
The appearance after crimping is shown in Picture2. The dielectric of the cable may be deformed
but it doesn’t affect the product’s function.
GT21B-2426/1.6-2.9PCF Appearance after crimping
GT21B-2426/1.6-2.9SCF Appearance after crimping
Picture2 Appropriate appearance after crimping
The shield braid may be trapped between the edges of the shield barrel but it does not affect the
quality of the product unless it exceeds the area of the shield barrel.
Jan.1.2022Copyright2022HIROSEELECTRICCO.,LTD.AllRightsReserved.

HIROSE ELECTRIC CO.,LTD.
ETAD-T0685-01
0
6/ 8
FORM HC0011-9-2
△
Crimp quality standard
①Position of crimping
A※1
0.1 MIN
B※2
0.35 MAX
C
1.0-2.0
D
0.3-1.0
※1 There is no problem in quality if the wire can be verified at the edge of the wire barrel.
※2 In case of inspecting by appearance, verify that the cable dielectric exceeds b1.
②Bendinig up, bending down
E
-10°MAX
F
-5°MAX
G
10°MAX
H
5°MAX
③Rolling
I
±5°MAX
J
±5°MAX
b1
B
C
A
D
Jan.1.2022Copyright2022HIROSEELECTRICCO.,LTD.AllRightsReserved.

HIROSE ELECTRIC CO.,LTD.
ETAD-T0685-01
0
7/ 8
FORM HC0011-9-2
△
④Twisting
K
±5°MAX
L
±5°MAX
⑤Cutoff tab
M
0.3MAX
⑥Crimp burr height
N1
0.05MAX
N2
0.15MAX
N3
0.05MAX
⑦Bell mouth
P
0.1-0.4
Jan.1.2022Copyright2022HIROSEELECTRICCO.,LTD.AllRightsReserved.

HIROSE ELECTRIC CO.,LTD.
ETAD-T0685-01
0
8/ 8
FORM HC0011-9-2
△
(4)Recommended inspection
①Appearance
Should be free from flaws, deformations, plating separation etc.
②Withstand voltage
Should be free from short circuit or insulation breakage when 600V AC is applied for one
second.
2mA leak current should be regarded as insulation breakage.
③Conduction
The inner conductor and outer conductor should be conductive.
4.Instructions
(1)Do not touch the terminal contacts or inside of the barrel.
(2)Do not put any object on a terminal. Do not drop terminals. Otherwise, terminals may be
deformed or become dirty. Handle terminals carefully.
(3)Do not pull terminals forcedly when they are entangled. Disentangle carefully to avoid
deforming them.
(4)Be careful not to deform terminals when touching them.
(5)Do not store terminals in a dusty place.
(6)Do not apply intense shocks to terminals.
(7)Do not put wire harnesses on the floor.
(8)Connectors are easily affected by shocks. Do not throw or swing them.
(9)Do not handle parts in such a manner as the connector is deformed or flawed or terminals
are deformed.
5.Storage Conditions
Storage place
Temperature & humidity conditions
Storage period
Indoor storage
15~30℃、60%RH or less
Six months (in our packing condition)
Store the products in a place that meets the following conditions, if they cannot be stored in
an air-conditioned warehouse as shown above. Do not store the products in a place with much
humidity or dust, exposure to direct sunlight, etc.
Storage place
Temperature & humidity conditions
Storage period
Indoor storage
-30~60℃、60%RH or less
Six months (in our packing condition)
Jan.1.2022Copyright2022HIROSEELECTRICCO.,LTD.AllRightsReserved.
Table of contents