– 15 –
ENGLISH
LEAVE HOME(LH) OPERATION
ƵTo start LEAVE HOME operation
Press (LEAVE HOME) button during stop or operation.
ƽ
Room temperature is set at 10°C and heating operation starts.
“ ”, “ ”, “ ”, “ ” is displayed on the LCD.
Press (LEAVE HOME) button during stop or operation.
Room temperature is set at 10°C and heating operation starts.
“ ”, “ ”, “ ”, “ ” is displayed on the LCD.
ƽSet number of operation days (1 to 99 days), if needed.
Press (TIME) button to select number of days.
Number of days blink.
* Press “
(UP)” to set number of days from 1 day, 2 days, 3
days ..... 98 days, 99 days, 1 day and so on.
* Press “
(DOWN)” to set number of days from 99 days, 98
days, 97 days .... 3 days, 2 days, 1 day, 99 days and so on.
* Number of day is counted when clock indicates 0:00.
ƽ Press (SEND) button to confirm number of operation
days. Display for number of operation days will stop blinking.
ƽPress (CANCEL) button to reset number of operation
days or to have continuous operation.
ƵTo cancel LEAVE HOME operation
ƽPress (START/STOP) button.Or
ƽPress (LEAVE HOME) button again.
ƽChange to other operation mode by pressing (MODE) button.
NOTE
ƽAfter reaching the set number of operation days for Leave Home or by pressing the (Leave Home) button again,
ƽDuring Leave Home operation, fan speed and horizontal air deflector position cannot be changed.
ƽBy pressing (Leave Home) button, implementation of Weekly Timer or One Timer only Timer is cancelled.
ƽ In case of power supply shut down, after autorestart, all setting for number of days operation will be reset and unit
shall be in continuous operation.
ƽ
For multi connections, when each room is running in different operation mode such as FAN only, COOLING, DEHUMIDIFYING
or AUTO mode, Leave Home operation cannot operate even though it is possible to set Leave Home operation.
In order to start Leave Home operation, all rooms must stop its operation. Then, press (LEAVE HOME) button to
operate Leave Home operation.
ƽ For multi connections, when all rooms are running HEATING operation, it is possible to operate Leave Home operation
by pressing the (LEAVE HOME) button.
ƽ For multi connections, if two or more rooms are set to operate Leave Home operation, the capability to reach the
set temperature at 10°C may not possible. In addition, this also depends on outdoor temperature.
Continuous operation
Day timer operation
Prevent the room temperature from falling too much by setting temperature automatically when no one is at home.
This operation is able to operate by" Continuous operation" or " Day timer operation" . Please use " Day timer operation"
to set the number of days up to 99 days.
10°C
ƽ
Option 1. Continuous operation.
Option 2. Day timer operation.
Return to previous operation mode.Or
othe unit will operate in previous mode.
POWERFUL,SILENT and ECO operations are not applicable during Leave Home.
ƽ
1
– 16 –
CLEAN (ONE TOUCH CLEAN) OPERATION
Drying indoor heat exchanger after cooling operation to prevent mildew.
ƵTo start CLEAN operation
ƵTo cancel CLEAN operation
ƽ Press (CLEAN) button when unit is OFF.
Total time taken for One Touch Clean operation is 60 minutes.
During this operation, HEATING or FAN operation shall
operate.
During one touch clean, operation lamp is blinking.
“ ”, “ ” is displayed on the LCD.
ƽ Press (START/STOP) button.Or
ƽ Press (CLEAN) button again.
1
NOTE
ƽ When CLEAN operation finish, unit will switch OFF automatically.
ƽ
ƽ For multi connections, when pressing (CLEAN) button, operation is limited to FAN operation.
ƽ For multi connections, when one room operates CLEAN operation first, other rooms can operate
COOLING, DEHUMIDIFYING or FAN operation. However, when other rooms need to operate HEATING
operation, air conditioner will be in STANDBY mode. After CLEAN operation finish, HEATING operation
will start.
If Weekly Timer or Once Timer is set, there is a need to cancel those timer before operating CLEAN function.