Homeworks QS HQP6-MDU Installation instructions

Lutron®|1www.lutron.com
product specifications 01.24.13
369755a
HomeWorks®QS MDU Processor
The HomeWorks®QS MDU processor provides
control and communication to HomeWorks®QS
system components.
The Ethernet links allow communication to the
HomeWorks®QS software, integration with third
party systems and control from the LutronRHome
Control+ mobile device application.
The processor is typically powered from the
QSPS-DH-1-60 power supply.
The HomeWorks®QS MDU processor can
be installed in a HQ-LV21, L-LV21 or L-LV14
enclosure.
Processor Capabilities
The HomeWorks®QS MDU processor has 2
links that are preconfigured as HomeWorks®QS
Wired Link and HomeWorks®QS RF Link. The
processor has a capacity of 50 devices/50 zones
maxiumum, shared between the two links. Refer to
HomeWorks®QS MDU System Architecture for a
list of devices for each link type.
Model Number
HQP6-MDU HomeWorks®QS MDU Processor

2 |Lutron®24/7 Technical Support—800.523.9466
product specifications 01.24.13
369755a
HomeWorks®QS MDU Processor
Specifications
Model Numbers HQP6-MDU
Power Processor (P): 24 V-250 mA
Links (L1 / L2): 24 V-2 A per link
Typical Power
Consumption
5 W; 8 Power Draw Units (PDUs)
Test conditions: Two Ethernet links connected, both device links in use
Regulatory Approvals UL, cUL, CE, CTICK
Environment Indoor use only. 32°F to 104°F (0°C to 40°C), 0%to90%humidity,
non-condensing
Heat Generated 17 BTU/hr — typical
(24 BTU/hr with 2 links at 2 A each output)
Cooling Method Passive Cooling
Power Failure Memory System data stored in non-volatile memory. Timeclock retention for 10years
Internal Timeclock ±1 minute per year
Miswire Protection All terminal block inputs are over-voltage and miswire protected against wire
reversals and shorts.
Low-Voltage Link
Wire Type
Two pair — one pair 18 AWG (0.75mm2), one pair 18 to 22 AWG
(0.34 to 0.75mm2)twisted shielded — IEC PELV / NEC®Class 2 cable
Low-Voltage Power
Wire Type
18 AWG (0.75mm2)
Communications Ethernet, RS485 (QS, RF, Power Panel)
Link Capacities Total link capacity between the HomeWorks®QS Wired Device Link and the
HomeWorks®QS RF Link cannot exceed 50 devices / 50 zones.
ESD Protection Meets or exceeds the IEC 61000-4-2 standard
Surge Protection Meets or exceeds ANSI/IEEE C62.41 standard
Mounting Mounts in HQ-LV21, L-LV14, or L-LV21
Dimensions With terminal blocks (as shown): 4.27 in (108 mm) x 6.0 in (152 mm)
Without terminal blocks: 4.27 in (108 mm) x 5.26 in (134 mm)
Connections Two 5-pin removable terminal blocks* for Links 1 and 2.
One 5-pin removable terminal block* for Power Input.
Two RJ 45 standard Ethernet connections.
* Each terminal will accept up to two 18 AWG (0.75mm2) wires.
Warranty http://www.lutron.com/TechnicalDocumentLibrary/HomeWorks_Warranty.pdf
http://www.lutron.com/TechnicalDocumentLibrary/ HomeWorks_Intl_Warranty.pdf
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.

Lutron®|3www.lutron.com
product specifications 01.24.13
369755a
HomeWorks®QS MDU Processor
Dimensions
Dimensions shown as: in (mm)
Front View Side View
1.06
(26.9)
6.0 (125)
5.26 (134)
4.27 (108)

4 |Lutron®24/7 Technical Support—800.523.9466
product specifications 01.24.13
369755a
HomeWorks®QS MDU Processor
Wire Landing Boards
(QS-WLB)
Example Mounting
L-LV14
(5) Ground
(4) Red L2 (Link 2) Power
(3) Red L1 (Link 1) Power
(2) Red P (Processor) Power
(1) Black COM (Common)
DIN Rail
Power Supply
(QSPS-DH-1-60)

Lutron®|5www.lutron.com
product specifications 01.24.13
369755a
HomeWorks®QS MDU Processor
Wiring Diagrams—Networking
WANLAN
Laptop PC
Ethernet cable:
Cat5/Cat5e
328 ft (100 m) maximum each run
Ad-hoc Networking: Direct Ethernet connection from PC to MDU processor
Standard Networking: Connection using an Ethernet hub/switch/router
WANLAN
Laptop PC
Ethernet Router
HomeWorksRQS
MDU processor
HomeWorksRQS
MDU processor
Ethernet cable:
Cat5/Cat5e
328 ft (100 m) maximum per home run
328 ft (100 m) max
3rd Party Integration Device
(not supplied by Lutron)

6 |Lutron®24/7 Technical Support—800.523.9466
product specifications 01.24.13
369755a
HomeWorks®QS MDU Processor
Wiring Diagrams— HomeWorks®QS Processor
L(+) N(-)
QSPS-DH-1-60
120 - 240V
Input / Entrada / Entrée
24V
Output / Salida / Sortie
22.5 - 25V
Max 2A combined Draw from
processor when powering both
links from the same power supply
(5) Ground
(3) Red L1 (Link 1) Power
(2) Red P (Processor) Power
(1) Black COM (Common)
(1) Black COM
(Common)
(4) Red L2
(Link 2) Power
up to 50 device addresses*
up to 50 device addresses*
RF Link
QS Link
* Total link capacity between the HomeWorks®QS Wired Device Link and the HomeWorks®QS RF
Link cannot exceed 50 devices / 50 zones.

Lutron®|7www.lutron.com
product specifications 01.24.13
369755a
HomeWorks®QS MDU Processor
Wiring Diagrams—HomeWorks®QS RF Link
* HomeWorks®QS Hybrid Repeaters can be powered from the Processor link or a wall-mount transformer.
If powering from a wall-mount transformer, Pin 2 does not get connected. A maximum of 4 hybrid repeaters can be
used with the HQP6-MDU processor.
Add
Test
Setup
Wired
RF
Communication
Repeater Status
13 4
2
P
Hybrid Repeater
PowerRepeaterLink
COM
24V
9V
1
MUX
MUX
234
Activate
Test
Hybrid Repeater
Add
Test
Setup
Wired
RF
Communication
Repeater Status
13 4
2
P
Hybrid Repeater
Power RepeaterLink
COM
24V
9V
1
MUX
MUX
234
Activate
Test
Add
Test
Setup
Wired
RF
Communication
Repeater Status
13 4
2
P
Hybrid Repeater
Power RepeaterLink
COM
24V
9V
1
MUX
MUX
234
Activate
Test
HomeworksRQS Processor
HQP6-MDU
HomeworksRQS RF Link *
1000 ft (305 m) maximum wire length per run
HomeworksRQS RF Link *
HomeworksRQS
RF Link *
HomeworksRQS
RF Link *
30 ft (9 m)
maximum
30 ft (9 m)
maximum
30 ft (9 m)
maximum
60 ft (18 m)
maximum
HomeworksRQS Hybrid Repeater
HomeworksRQS RF Link *
1000 ft (305 m) maximum
wire length per run

8 |Lutron®24/7 Technical Support—800.523.9466
product specifications 01.24.13
369755a
HomeWorks®QS MDU Processor
Wiring Diagrams—HomeWorks®QS Wired QS Link
with Shades / Draperies (Controllable Window Solutions)
L(+) N(-)
QSPS-DH-1-60
120- 240 V
Input/ Entrada / Entrée
24V
Output/ Salida / Sortie
22.5- 25 V
HomeworksRQS wired devices
HomeworksRQS wired devices
QS Link
120 V~
60 Hz
QSPS-P1-10-60
QS Smart Power
Panel
Table of contents
Other Homeworks Computer Hardware manuals
Popular Computer Hardware manuals by other brands

EMC2
EMC2 VNX Series Hardware Information Guide

Panasonic
Panasonic DV0PM20105 Operation manual

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 user manual

Gigabyte
Gigabyte B660M DS3H AX DDR4 user manual

Raidon
Raidon iT2300 Quick installation guide

National Instruments
National Instruments PXI-8186 user manual