HomLiCon LCH5LP User manual

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 1
5 Channel Multifunctional PWM Controller
HomLiCon LCH5LP
Application
Control of groups LED, LED strips, LED modules
Color Organ, Sound Activated Light Show, Light Sequencer, etc.
Home Automation
Technical Specifications
Number of Channels
5
Color organ number of channels
4+ Inverse Channel
Supply voltage
12 V DC (9 –16 V DC)
Maximum output current per channel
2 A
Maximum total output current
10 A
Current consumption
15 mA
Number of stored levels and settings
10
Color Organ bandwidths
LF 50−200Hz , MF 200Hz−1kHz ,
MHF 1−7kHz, HF 7−14kHz
Line-in nominal level (set standard / high sensitivity)
0.3 V RMS /0.15 V RMS
Line-in maximum level
1.5 V RMS
Mic-in range of sound level (with module MACL - optional)
60 - 120 dB
PWM steps for each channel
110
Dimensions LCH4F
48 x 48 x 20 mm
Dimensions Remote
85 x 40 x 7 mm
Ambient temperature
5 −40°C

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 2
Controller Features
Control of all settings and functions through the remote control included in the kit.
Three main modes:
Color Organ, Sound Activated Light Show
Light Sequencer
Lighting
Switch with a press of a button between the previously saved custom 10 groups, different levels for all
channels or Light Show settings.
Easy save of 10 custom groups, different levels for all channels or Light Show settings.
Activation of Light Show controlled by sound from microphone, Line-in or unsynchronized.
Fully automatic Color Organ with AGC (Automatic gain control) and digital division of the
bandwidth in 4 range: LF 50 - 200Hz , MLF 200Hz - 1kHz , MHF 1 - 7kHz, HF 7 - 14kHz.
Level Meter with / without AGC (Automatic gain control).
Automatic or manual switching between different programs of Light Show.
Adjust sensitivity AGC (Automatic gain control) for Color Organ separately for each frequency channel LF,
MLF, MHF, HF in 4 levels, saved separately for each audio input.
Equalize or adjust the light intensity for channels in Light Show.
Setting the maximum level for inverse channel in Light Show.
Gradually increase or decrease the light intensity when you turn ON or OFF each PWM channel.
Gradually increase or decrease the light intensity for all channels to reach the preset levels when you select
one of the ten preset functions.Ability to set PWM control for each channel or ON/OFF option.
Ability to choose if the channels are OFF or a saved function is activated when the supply voltage is applied.
LED on each one of the channels connected to the microcontroller pins for indication and diagnostics.
Power MOSFET for the output of each channel.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 3
1.0 Basic operations and wired diagram
1.1 Light Show basic operations
All operations and settings are performed by the included IR remote control.
Button
Description
More info in
section:
Turns OFF all channels /Turns ON the saved functions for button 9
2.1
2.2
ON / OFF Light Show
5.1
Next Light Show program (to 10)
5.2
5.4
5.11
Previous Light Show program (to 1)
5.2
5.4
5.11
TEST
Lighting mode: Turns all channels ON
Light Show mode: ON / OFF the synchronization of sound and Light Show
(Color organ, Level meter OR Light Sequencer)
5.3
MENU ,
Line input (3.5mm stereo jack).
The interval between buttons must not exceed 2 seconds.
5.4
MENU ,
Microphoneinput
The interval between buttons must not exceed 2 seconds.
5.4
Note: See section 5.0 for more details
Table programs of 4 Channel Light Show
Remote control buttons: ON / OFF , Next program (to 10)., Previous program (to 1)
№
Programs with sound control
Programs without sound control
1
AUTO - automatic switching between programs 3 - 10, while at a
low sound level - switches to program 2
AUTO - automatic switching
between programs 3 - 10
2
Smooth transitions sequence (PWM) without sound control
3
Color organ with smooth transitions (PWM)
Chaser –►
4
Color organ classic
Chaser –►, ◄–
5
Level meter –►
Fill –►, ◄–
6
Level meter ◄–
Chaser dark dot –►
7
Level meter single dot –►
Chaser ◄–
8
Level meter 2 dot ◄–
Fill ◄–, Chaser ◄–, etc.
9
Level meter with beat detection shift –►
Chaser –►, Fill ◄–, etc.
10
Level meter with beat detection shift ◄–
Fill –►

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 4
Table of the Factory Pre Stored Light Show Functions (You can change these settings)
Button
Function
№ Program
Signal input
0
Light Show without sound sync. (Light Sequencer) - AUTO Program
Program 1
–
6
Light Show –Color organ classic
Program 4
Line-In
7
Light Show –Level meter
Program 5
Line-In
8
Light Show –Color Organ smooth transitions (PWM)
Program 3
Line-In
9
Light Show with sound sync.–AUTO Program –switch between
programs 3 - 10, while at a low sound level - switch to program 2
(Smooth transitions sequence (PWM) without sound control}
Program 1
Line-In
Note 1: Button Turns OFF all channels /Turns ON the saved functions for button 9.
Note 2: See section 2.0 for more details

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 5
1.2 Wiring diagram and description
The supply voltage 12V DC must be connected to the terminal blocks marked +and −.
All +terminals of the LED strips / modules must be connected together in a terminal outside the controller and a
single wire from this connection must be connected to the terminal marked + L on the controller.
Each of the −terminals of the LED strips / modules must be connected to terminals 1, 2, 3, 4, 5 respectively.
Notе: First, install spacers in the mounting holes on the board to protect the installed components.
More connection options can be found on the last pages.
Warning:
–Outputs do NOT have protection from short circuit, overload or reverse voltage.
Improper connection will lead to a damaged controller.
–Line-in audio signal must be from the Line-out of a player, computer (green jack) or
smartphone. Do not use a speaker output from amplifier or car audio. Adjust
(increase) the level of the player until the channels start to turn on.
–Individual and/or POWER LEDs must be connected by a series resistor limiting the
current to nominal (in LED strips and modules is embedded).
–Do not connect POWER LEDs or LED COBs that are powered by a driver or inverter
(small electronic board).

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 6
2.0 Stored Functions - Settings and Operation
All operations and settings are performed by the included IR remote control.
2.1 Stored Functions - Easy Switching Between Different Levels and Settings
Buttons 1, 2, 3, 4 and 5 are used for control of the corresponding channels in Lighting mode or as part of
the ten buttons for stored functions. Switching is performed with the button . When buttons 1, 2, 3, 4 and 5
used for channels control, STATUS LED flashes with short pulse (0.01s) and a long pause (2s).
You can quickly switch between the different saved light levels and Light Show settings with the use of
the buttons 0, 1, 2, ..., 9, and the levels will change smoothly until the new values are reached.
Table of the Factory Pre Stored Functions (You can change these settings)
Button
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
0
Level 10%
Light Show without sound sync. - Program 1 - AUTO Program
1
Level 100%
Level 30%
Level 100%
Level 30%
Level 100%
2
Level 20%
Level 100%
Level 20%
Level 100%
Level 20%
3
Level 10%
Level 10%
Level 100%
Level 10%
Level 10%
4
Level 10%
Level 40%
Level 40%
Level 100%
Level 40%
5
Level 0%
Level 100%
Level 100%
Level 100%
Level 100%
6
Inverse channel
Light Show - Program 4 - Color organ classic - Line-In
7
Inverse channel
Light Show - Program 5 - Level meter ––►- Line-In
8
Inverse channel
Light Show –Program 3 - Color Organ (PWM) - Line-In
9
Inverse channel
Light Show with sound sync. - Program 1 - AUTO - Line-In
Note 1: Button Turns OFF all channels /Turns ON the saved functions for button 9.
Note 2: The functions are the highest priority. No matter what mode is the controller using, the function
button will activate the appropriate stored settings. The buttons 0 , 6 , 7 , 8 , 9 are always used for switching
functions.
2.2 Saving Functions
You can save the present levels and Light Show settings in the non-volatile memory by sequentially
pressing and releasing the buttons MENU and one of 0, 1, 2, ..., 9 (the interval between pressing the buttons
should not exceed 2 seconds).
List of the settings are stored separately for each of the buttons from 0to 9 :
Levels of the channels (Lighting mode)
ON/OFF Light Show
If Light Show is activated:
The present program
Programs with or without sound synchronization
Audio input: Line-in or Microphone
4 channel Light Show (channels 2, 3, 4, 5) or 3 channel (channels 3, 4, 5)
ON/OFF inverse channel (channel 1)
Note:
–The Light Show settings are stored separately for each function button 0to 9and the button for a
total of 11 groups.Changing one setting will save all active at that time, only for the button .
–The settings for each function key 0to 9are saved only with the buttons MENU , 0 to 9.
–Light Show can not be activated if it is disabled by the sequence: MENU , , 0.You can find more
info about these settings on section 5.13.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 7
3.0 Lighting mode - Channels control
3.1 Setting the levels for the channels
The controller is in lighting mode when the light show is OFF.
Buttons 1, 2, 3, 4 and 5are used for control of the corresponding channels or as part of the ten buttons
for stored functions. Switching is performed with the button - alternatively. When buttons 1, 2, 3, 4 and 5
are used for channels control, STATUS LED flashes with short pulse (0.01s) and a long pause (2s).
A single button system is used for regulating each channel and it is as follows:
I. By pressing and releasing the button for specific channel the light’s intensity is increasing.
II. After the next pressing and releasing it is fixed on the current level.
III. After pressing and releasing again - the light’s intensity is decreasing.
IV. After the next pressing and releasing it is fixed on the current level.
By repeating steps I - IV or part of them the required level can be reached.
For more precise adjustment the +and –buttons can be used. They regulate the last channel
that was used, or the selected one by pressing and releasing the button Cand the button for the
specific channel (1 to 5).
Note: The options for controlling the device have the following priority:
1. Buttons for functions
2. Light Show control buttons
3. Buttons for channels control
3.2 Adjusting the speed of smooth transitions when switching channels
The speed settings of smooth channels switching and speed settings in Light Show program 2 –“Smooth
transitions sequence” is the same.
The adjustment can be made in the light show program 2 by +and –buttons.
You can find more info about these settings on section 5.9.
3.3 Setting the channels in PWM or ON/OFF mode
You can switch certain channels in PWM or ON/OFF by turning on the necessary channels for ON/OFF
mode and sequentially press and release the MENU , , 1((the interval between pressing each of the
buttons should not exceed 2 seconds). With this combination, the turned ON channels are stored in non-volatile
memory with function ON/OFF, and the turned OFF channels with PWM. After such a change it is
recommended the stored values and settings for buttons 0, 1, ..., 9 to be made again.
Note: Channels that are in ON/OFF mode do not work correctly in Light Show.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 8
3.4 Table of General Settings
Settings changes can be made by successively pressing and releasing the following buttons:
MENU , , 1
Switching certain channels of PWM or ON / OFF can be made by turning ON the
necessary channels for ON/OFF mode and sequentially press and release the MENU,
, 1. With this combination, the turned ON channels are stored in non-volatile
memory with function ON/OFF, and the turned OFF channels with PWM. After such a
change it is advisable the stored values and settings 0, 1, ..., 9 to be set again.
MENU , , 7
After applying the supply voltage, the channels are OFF.
MENU , , 8
After applying the supply voltage, turns on the saved functions for button 9.
MENU , , 0
Reset the user settings and return the original (factory) or just reboot. It activates
STATUS LED - ON/OFF in 0.1 seconds, while awaiting confirmation with button +
to return to initial (factory) settings, button –for RESET or another button to exit.
Note: The interval between each button must not exceed 2 seconds.
3.5 Hardware return to factory settings
1) Turn Power OFF
2) Place jumper J5 pins 2 and 3 (Caution: incorrectly placed jumper on pins 1 and 2 can
damage the controller)
3) Turn Power ON
After 2-3 seconds or when STATUS LED turns ON :
4) Turn Power OFF
5) Remove jumper J5
4.0 Status LED Indication
For indication of the received infrared pulses and the current state of some features is used STATUS
LED. When the buttons 1, 2, 3, 4 and 5are used for the control of specific channel in Lighting mode, STATUS
LED flashes with short pulse (0.01s) and a long pause (2s). After pressing the button MENU the status LED is
activated for 2 seconds (on/off in 0.1 sec.) as indication for waiting for the next button to be pressed.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 9
5.0 Light Show Control and Settings
5.1 Turning ON / OFF Light Show
Turn ON / OFF Light Show by pressing button .
Note:
–When Light Show is activated by pressing button , the last saved settings will be activated instead
of the last used settings by the function keys 0to 9.The Light Show settings are stored separately for
each function button 0to 9and the button for a total of 11 groups. Changing one setting will save
all active at that time, only for the button .
–Light Show can not be activated if it is disabled by the sequence: MENU , , 0.You can find more
info about these settings on section 5.13.
5.2 Switching programs
You can switch between programs with the buttons:
–next program (to 10)
–previous program (to 1)
5.3 Switching between programs with/without sound control
The button TEST is used (if Light Show is activated) to switch between two groups of programs:
–programs with sound control - Color organ, Level meter, etc.
–programs with self patterns - Chaser, moving light, etc.
5.4 Switching between audio inputs
You can switch between audio inputs with the following key sequence:
–MENU ,-Line-in
–MENU ,-Microphone
The interval between each button must not exceed 2 seconds.
5.5 Setting Line-in Audio Sensitivity
When using a Line-in, you can choose between two sensitivity levels with the buttons:
- Standard sensitivity (default)
+ High sensitivity
To adjust the sensitivity of the line input, the controller must be set to one of the Light Show programs
with sound control (programs 3 to 10 - Color organ, Level meter, etc.).
First pressing one of the +or -buttons only serves to indicate the current sensitivity state for a period
of 2 seconds: Standard sensitivity - channel 3 ON (green)
High sensitivity - channel 4 ON (blue)
Note 1: Press the Cbutton before adjusting the sensitivity if you have already made other settings (eg
those in section 5.7).
Note 2: This setting is unavailable when using the microphone input.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 10
5.6 Setting maximum brightness levels for channels in Light Show and Inverse
Channel
Some colors LEDs are brighter than others. With this option, you have the ability to equalize brightness.
You can equalize or adjust the light intensity for channels in Light Show and set the maximum level for inverse
channel.
5.6.1 View maximum brightness levels for channels in Light Show and Inverse Channel
You can visualise the present levels with key sequence: C ,(Light Show must be switched OFF).
5.6.2 Setting maximum brightness levels for channels in Light Show and Inverse Channel
1. Turn OFF Light Show ( button or ) .
2. Set the channels to desired levels(See section 3.1) or visualise the present levels with key
sequence: C ,and adjust them.
3. Save the new levels by pressing and releasing the following buttons:
MENU ,,C .
Note:
–The interval between each button must not exceed 2 seconds.
–This setting does not affect program 2 –“Smooth transitions sequence (PWM) without sound control”.
–For proper operation of Light Show program 3, the maximum level of channels should not be less
than 15%.
5.7 Setting Audio Sensitivity AGC (Automatic gain control) for Color Organ
You can adjust sensitivity AGC for Color Organ separately for each frequency channel LF, MLF, MHF, HF
in 4 levels. These settings are saved separately for each audio input - for 4 frequency channels on Line-In and
for 4 on Microphone-In.
To adjust the sensitivity, the controller must be set on one of the two programs for Color Organ (program
2 or 3), and buttons 1 to 5 must be set for channels control (button - status led flashes with short pulse
0.01s and a long pause 2s).
The selection of the channel that you want to adjust is made by pressing one of the buttons 2, 3, 4, 5
respectively for frequency channels LF, MLF, MHF, HF. By pressing one of the buttons 2 to 5, the present level
of sensitivity is displayed on the output channels 2, 3, 4, 5 as a level bar, where level 1 (which is the lowest
sensitivity) will turn on channel 2 and level 4 ( which is the highest sensitivity) will turn on channels 2,3,4 and 5.
The selection of a channel is active until another channel is selected or the program is switched.
Table of Sensitivity level AGC
Sensitivity level
AGC
Sensitivity displayed on the
output channels 2, 3. 4, 5
Sensitivity level
AGC
Sensitivity displayed on the
output channels 2, 3. 4, 5
1 (lowest)
☼● ● ●
3
☼☼ ☼ ●
2
☼☼ ●●
4 (highest)
☼☼ ☼ ☼
The adjustment for the selected frequency channel is made by buttons +and -, and the levels are
visualized on the output channels 2, 3. 4, 5. Pressing the button once serves only for visualization. Pressing it
again serves for regulation. After the change of sensitivity it takes some time (3 –15s) for activation of the new
settings.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 11
Table of the Factory Pre Stored Levels Sensitivity (You can change this settings)
Frequency
channel
Button
to
select
Line-In
factory pre
stored level
Line-In level displayed
on the output channels
2, 3. 4, 5
Microphone-
In factory pre
stored level
Microphone-In level
displayed on the output
channels 2, 3. 4, 5
LF
2
3
☼☼ ☼ ●
4
☼☼ ☼ ☼
MLF
3
3
☼☼ ☼ ●
4
☼☼ ☼ ☼
MHF
4
3
☼☼ ☼ ●
4
☼☼ ☼ ☼
HF
5
3
☼☼ ☼ ●
4
☼☼ ☼ ☼
5.8 Adjusting the speed in the programs without sound synchronization
You can adjust the speed of programs without sound synchronization by buttons +and -.
5.9 Adjusting the speed in program 2 –“Smooth transition sequence”
You can change the speed of the smooth transition in program 2 –“Smooth transition sequence (PWM)
without sound control” with buttons +and -.
Note: This setting affects the speed of smooth transitions when switching channels in Lighting mode.
5.10 Determining the optimal voltage of the audio signal -
Level meter without AGC (Automatic gain control)
To determine the optimal audio signal level (Line-In only), you can temporarily turn OFF the AGC. When
program 5 is active (Level meter –►) you can select the use of the AGC:
–Button 4- turn ON AGC (default)
–Button 5- turn OFF AGC
Table of input voltage when the AGC is turned OFF for the corresponding display of channels 2, 3, 4, 5
Line-In input voltage (RMS)
Level displayed on the output channels 2, 3, 4, 5
Standard / High sensitivity
Program 5 Level meter –►
0.1V / 0.05V
☼●● ●
Low level
0.2V / 0.1V
☼☼ ● ●
Optimal level
0.4V / 0.2V
☼☼ ☼ ●
Optimal level
0.5V / 0.25V
☼☼ ☼ ☼
High level
The level is optimal when channels 1 and 2 are ON and channel 3 is flashing.
Note:
1. This setting will not be saved. Exit from program 5 automatically turns ON the AGC.
2. Program 5 and switched OFF AGC can be saved to a function key (see section 2.2).
3. AGC can be turned OFF when MIC-IN is active. The voltages for switching ON channels 1 - 4 are
respectively: 0.25V, 0.5V, 1V, 1.25V.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 12
THERE ARE TWO TYPES OF LIGHT SHOW ACCORDING TO THE NUMBER OF
CHANNELS USED :
5.11 4 Channel Light Show (channels 2, 3, 4, 5)
TABLE PROGRAMS OF 4 CHANNEL LIGHT SHOW
№
Programs with sound control
Programs without sound control
1
AUTO - automatic switching between programs 3 - 10, while at a
low sound level - switches to program 2
AUTO - automatic switching
between programs 3 - 10
2
Smooth transitions sequence (PWM) without sound control
3
Color organ with smooth transitions (PWM)
Chaser –►
4
Color organ classic
Chaser –►, ◄–
5
Level meter –►
Fill –►, ◄–
6
Level meter ◄–
Chaser dark dot –►
7
Level meter single dot –►
Chaser ◄–
8
Level meter 2 dot ◄–
Fill ◄–, Chaser ◄–, etc.
9
Level meter with beat detection shift –►
Chaser –►, Fill ◄–, etc.
10
Level meter with beat detection shift ◄–
Fill –►
In this mode Channel 1 can be used for:
–Inverse Channel. When the channels 2, 3, 4 and 5 are OFF, channel 1 is switched smoothly to
previously stored level. It works only for 4 channel light show and synchronization with sound.
–Backlight with adjustable level 0 - 100%.
5.12 3 Channel Light Show (channels 3, 4, 5)
The available programs that can be used are from 1 to 6 (view Table programs of 4 Channel Light Show).
Setting Audio Sensitivity AGC is not available, but the corresponding values from 4 Channel Light Show
[channel MF= (MLF + MHF) /2] is used.
In this mode Channel 1 and Channel 2 can be used for backlight with adjustable level 0 - 100%.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 13
5.13 Table of General Settings for Light Show
Settings changes can be made by successively pressing and releasing the following buttons:
MENU , , 0
Disable Light Show
MENU , , 3
Enable 3 channel Light Show - used channels 3, 4 and 5
MENU , , 4
Enable 4 channel Light Show - used channels 2, 3, 4 and 5. [DEFAULT]
MENU , , 5
Disable the use of inverse channel
MENU , , 6
Allow the use of channel 1 for inverse channel. When the channels 2, 3, 4 and 5 are
off, channel 1 is switched smoothly to previously saved level. It works only for Light
Show with 4 channels and synchronization with sound. [DEFAULT]
MENU , , 7
The range of low frequencies for color organ are set to 50 - 180Hz [DEFAULT]
MENU , , 8
The range of low frequencies for color organ are set to 50 - 250Hz. It is recommended
when using speakers that do not reproduce low frequencies well.
Note: The interval between each button must not exceed 2 seconds.

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 14
6.0 Description of the remote control buttons
Button
Description
More info in
section:
Turns OFF all channels /turns ON the saved functions for button 9.
MENU
Save the present levels and Light Show settings in the non-volatile memory by
successively pressing and releasing the buttons MENU and one of 0, 1, 2,
3, 4, 5, 6, 7, 8, 9
2.2
3.4
5.13
TEST
Lighting mode: Turns all channels ON.
Light Show mode: ON / OFF the synchronization of sound and Light Show
(Color organ, Level meter OR Light Sequencer)
5.3
You can choose between buttons 1, 2, 3, 4 and 5to control the respective
channels, or as a part of the ten buttons (0- 9) for stored functions. When the
buttons 1 - 5 are used for control of the respective channels, STATUS LED
flashes with short pulse (0.01s) and a long pause (2s).
2.1
3.1
3.4
ON / OFF Light Show.
5.1
Next Light Show program (to 10) ; MENU ,-Line-in
5.2
5.4
Previous Light Show program (to 1) ; MENU ,-Mic-in
5.2
5.4
C
Select a channel to be precisely tuned with + and –
Sequentially press and release OK and one of 1,2,3,4,5.
3.1
–+
Lighting mode: Regulating the last used channel or the selected one.
Light Show - Programs with sound control:
- Standard sensitivity (default), + High sensitivity
Light Show - Programs without sound synchronization:
Speed control
3.1
5.5
5.7
5.8
5.9
1, 2, 3, 4, 5
Regulate or turns ON/OFF particular channel.(1)
2.1
2.2
5.7
5.10
0, 1, 2, 3, 4,
5, 6, 7, 8, 9
Switch between the saved Functions.(1)
2.1
2.2
3.1
NOTE 1: Buttons 1, 2, 3, 4 and 5are used to control the respective channels or as part of the ten buttons (0- 9)
for stored functions. Switching is performed by the button MODE.When they are used for channels
control, STATUS LED flashes with short pause (0.01s) and a long pause (2s).

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 15
Arrangement of the buttons on the remote control:
Battery CR2025 (not included in kit)

www.homlicon.com HomLiCon LCH5LP
2021 mc-kit.net Page 16
Connecting additional modules and various loads
Table of contents
Other HomLiCon Controllers manuals
Popular Controllers manuals by other brands

Crystop Display Gmbh
Crystop Display Gmbh AutoSat 2 Control user manual

KROHNE
KROHNE SU 502 Handbook

Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-R Series user manual

Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-R Series Migration guide

Siemens
Siemens RDF270 manual

AMX
AMX NetLinx Integrated Controller NI-700 installation guide