SUNDIAL Y PLAN
■Installation
Valve - Wat r flow must b into port
AB. Port A is th outl t conn ction to
th radiator circuit and port B to th
cylind r primary circuit.
Room Thermostat - Th th rmostat
must b locat d wh r not subj ct to
xtran ous h at gains, dir ct sunlight
or draughts.
Cylinder Thermostat - For optimum
p rformanc th th rmostat should b
locat d b tw n 1/
4and 1/
3up th
cylind r from th floor.
■Time Control
Standard ractice
A 2 chann l programm r to control th
HW and h ating zon s.
Best ractice
A tim switch to control HW and a
programmabl th rmostat for th
h ating zon .
Bypass Valve - An automatic bypass
valv should b fitt d to th syst m to
stop wastag of n rgy and pr v nt
incr as d pr ssur within th circuit.
Ev n though th r is always on valv
outl t op n: th bypass will guard
against th possibility of th h ating
circuit b ing isolat d by radiator
th rmostats or op ration of manual
radiator valv s.
■Operation
Hot Water Only Requirement - On a
d mand for h at from th cylind r
th rmostat, th valv r mains op n to
DHW only and th pump and boil r ar
switch d on.
Heating Only Requirement - On a
d mand for h at from th room
th rmostat, th valv motor is
n rgis d so that th CH port only is
op n d and th pump and boil r ar
switch d on.
HTG and HW Requirement - Wh n both
th rmostats d mand h at, th valv
ball is position d to allow both ports to
b op n and th pump and boil r
switch d on. Wh n n ith r th rmostat
is d manding h at, th pump and
boil r ar off. Th valv r mains in th
last position of op ration whilst th
mains is switch d on.
■Specification
Standard Sundial Y lan comprises:
V4073A1039 : 22mm 3 port mid-position valv
L641A1039 : Strap-on cylind r th rmostat
T6360B1028 : Room th rmostat
ST9400C1000 : 7 day full programm r
or
ST9400A1002 : 1 day full programm r
Automatic Bypass Valve
DU144A1001 : 22mm straight auto bypass valv
DU145 – 3/
4B : 22mm angl d auto bypass valv
Optional components
Y6630D1007 : Wir l ss analogu room th rmostat
T6620B1008 : DT200 digital room th rmostat
Best ractice
CMT901A1044 : 1 day programmabl th rmostat
CMT907A1041 : 7 day programmabl th rmostat
Frost protection
T4360A1009 : Frost Th rmostat
L641B1004 : Low limit Pip Th rmostat
■Typical Wiring
Not : It is r comm nd d that th 10 way Junction Box or Sundial Wiring C ntr
should b us d to nsur first tim , fault fr wiring.
© Honeywell Control Products and Systems, Issue 10, 2.5