Honeywell
T841A
Heating-Cooling Thermostats
INSTALLATION INSTRUCTIONS
APPLICATION
The T841A Thermostats provide 24 Vac control of two-
stage heating and one-stage cooling in heat p mp
systems sing man al changeover.
The T841A provides EM.HT.-HEAT-OFF-COOL system
switching and AUTO-ON fan switching.
Test holes are provided on the front of the thermostat to
accommodate test meter leads witho t removing the
thermostat from the wall. Remove the cover of the
thermostat to expose test holes that are labeled to
correspond with the terminals on the back of the thermostat.
Table 1. Thermostat Feat res.
Thermostat Terminal
Designations LEDs A to Fan in
EM. HT. Fig re
N mbers
T841A W3, W2, Y, G, R, E, X, O, B, L AUX. HT., EM. HT., CHECK Yes 2
W3, W2, Y, G, R, E, X, O, B, L AUX. HT., EM. HT. Yes 3, 4
W, Y, R, T, F, G, X2, O, B EM. HT., AUX. HT. Yes 5
W3, W2, Y, G, R, E, X, O, B —Yes 6
W3, W2, Y, G, R, E, X, O, B EM. HT., AUX. HT. Yes 7
W2, W1, Y1, G, R, E, X, O, B EM. HT., AUX. HT. Yes 8
W3, W2, Y, G, R, E, X, O, B EM. HT., AUX. HT. Yes 9
W2, W1, Y, G, R, K, Z, X EM. HT., SERVICE No 10
W2, H, Y, G, R, E, X, A, O, B EM. HT., COMP. FAULT No 11
W, Y, G, R, X, O, B EM. HT., AUX. HT. Yes 12
W2, W1, Y1, G, R, E, X, O, B, L EM. HT., AUX. HT. Yes 13
W2, W1, Y, G, R, E, C/X, O, B, EM. HT., AUX. HT. Yes 14
W, Y, G, R, T, F, X2, O, B, U EM. HT., AUX. HT. Yes 15
W2, Y, G, R, E, B, X —Yes 16
OPERATION
The stages of heat make seq entially as the temperat re
drops. Make refers to the merc ry switch initiating a call for
heat or cool.
There is abo t 1 °F (0.6°C) between stages so the second
stage (a xiliary heat) makes only when the first stage
cannot handle the load. This 1°F is the interstage
differential.
The light emitting diode (LED) indicators on certain
thermostat models light when something specific happens
within the system. The AUX. HT. LED lights when a xiliary
heat (second stage heat) is operating d e to extremely
cold weather that req ires additional heat to s pplement
the heat p mp. When the red EM. HT. LED lights, the
emergency heat is operating ( s ally electric strip
heaters), beca se the homeowner has physically switched
to the EM. HT. position. When the red CHECK LED lights,
it indicates that something needs to be done to maintain
efficient system operation. See heating/cooling
man fact rer's instr ctions for specific meaning. When the
yellow COMP. FAULT LED lights, a compressor problem
req ires attention. When the yellow SERVICE LED lights,
see heating/cooling man fact rer's instr ctions for specific
meaning.