WARNING
- Turning on the power switch starts to
heat the glue tank which will finally
reach a temperature of around 180
degrees Celsius. Keep your hands and
fingers away from the glue tank, other-
wise severe personal injury can result.
First, the clamper is needed to move to
the left end to perform the following
procedures.
1. Turn on the power switch and wait for the
start lamp to light which shows that the
hot-melt glue is ready for binding.
NOTE
It takes about 20 minutes to heat the hot-
melt when the BQ-140 was OFF, and about 7
minutes when the BQ-140 was in standby
mode.
2. Select with the binding mode
selector switch.
3. Insert the book block 0.04" (1 mm) into
the clamper so that the book block is
lifted about 0.2" (5 mm) from the nipper.
- The glue is not be applied on the spine.
4. Close the clamper by turning the clamp
handwheel clockwise.
5. Press the start button.
- The clamper moves to the left and stops at
the left end.
6. Press the stop button.
Cover Stopper Installation Instruction
Binding Mode
Selector Switch
Start
Button
Reset Button
Clamp
Handwheel
Stop Button
Power Switch
[Book Binder BQ-140]