CONTENTS PAGE
I. GENERAL INFORMATION --------------------------------------------------------------------------1
1. SAFETY INSTRUCTIONS-------------------------------------------------------------------------1
2. DIMENSIONS/SPECIFICATIONS ---------------------------------------------------------------3
[a] RTC-120SNA -------------------------------------------------------------------------------------3
[b] RTC-120SDA -------------------------------------------------------------------------------------4
[c] RTC-150SNA -------------------------------------------------------------------------------------5
[d] RTC-150SDA -------------------------------------------------------------------------------------6
[e] RTC-180SNA -------------------------------------------------------------------------------------7
[f] RTC-180SDA -------------------------------------------------------------------------------------8
II. TECHNICAL INFORMATION-----------------------------------------------------------------------9
1. WIRING DIAGRAM----------------------------------------------------------------------------------9
2. REFRIGERATION CIRCUIT -------------------------------------------------------------------- 10
3. ELECTRONIC CONTROLS --------------------------------------------------------------------- 11
[a] SET POINT TEMPERATURE -------------------------------------------------------------- 11
[b] CABINET TEMPERATURE DIFFERENTIAL ------------------------------------------- 11
[c] DEFROST CYCLE ---------------------------------------------------------------------------- 11
[d] DEFROST COMPLETION TEMPERATURE ------------------------------------------- 11
[e] CLOGGED CONDENSER DETECTION TEMPERATURE------------------------- 11
[f] TEMPERATURE DISPLAY CYCLE ------------------------------------------------------- 11
[g] COMPRESSOR SOFT START------------------------------------------------------------- 12
[h] CABINET TEMPERATURE AND TEMPERATURE DISPLAY---------------------- 12
[i] RESOLUTION ---------------------------------------------------------------------------------- 13
[j] SET POINT TEMPERATURE AND CABINET TEMPERATURE------------------- 13
[k] CHECKING AND ADJUSTING SET POINT TEMPERATURE --------------------- 13
[l] MANUAL DEFROST -------------------------------------------------------------------------- 14
[m] CANCELLING SOFT START -------------------------------------------------------------- 14
4. ERROR CODES ----------------------------------------------------------------------------------- 14
[a] EEPROM WRITE ERROR (EA) ----------------------------------------------------------- 14
[b] EEPROM VERIFY ERROR (ED) ---------------------------------------------------------- 15
[c] CABINET TEMPERATURE TOO HIGH (E1) ------------------------------------------- 15
[d] CABINET TEMPERATURE TOO LOW (E2)-------------------------------------------- 16
[e] DEFROST CYCLE TOO LONG (E3) ----------------------------------------------------- 16
[f] ABNORMAL PRESSURE (E4) ------------------------------------------------------------- 17
[g] CONDENSER CLOGGED (E7)------------------------------------------------------------ 18
[h] DEFROST THERMISTOR DEFECTIVE (E8) ------------------------------------------ 18
[i] CLOG THERMISTOR DEFECTIVE (E9) ------------------------------------------------ 19
5. ENERGY SAVING CONTROL------------------------------------------------------------------ 19
[a] STANDARD MODE --------------------------------------------------------------------------- 19
[b] ENERGY SAVING MODE ------------------------------------------------------------------- 20
[c] CABINET TEMPERATURE CORRECTION -------------------------------------------- 20
6. TIMING CHART ------------------------------------------------------------------------------------ 21
[a] STANDARD MODE (RTC series) --------------------------------------------------------- 21
[b] ENERGY SAVING MODE (RTC series) ------------------------------------------------- 22
[c] STANDARD MODE (FTC series) ---------------------------------------------------------- 23
[d] ENERGY SAVING MODE (FTC series) ------------------------------------------------- 24
[e] FORCED STARTUP (CANCELING SOFT START)----------------------------------- 24