HotWire TR8100V User manual

Menu # Feature Explanation Adjustment
(Press up & down buttons to adjust)
01 Mode/Sensor Selection
This thermostat is a combination model which allows you
to choose 3 different modes.
A mode = Air Sensing Only(Has built in sensor)
AF mode = Air & Floor sensing (Floor probe must be installed)
F mode = Floor Sensing(Floor probe must be installed)
A / AF / F
02 Switching differential
The number of degrees difference before switching.
The default is 1°C which means the thermostat will switch
the heating on 0.5°C below the set temperature and will turn
it off 0.5°C above the set temperature.With a 2°C differential
the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
1 Deg C, 2 Deg C....10 Deg C ( 1 Deg C by default)
03 Air Temp Calibration This is to recalibrate the air temp if required -1 Deg C = decrease 1 °C , 1 Deg C = increase 1 Deg C
04 Floor Temp Calibration This is to recalibrate the floor temperature if required -1 Deg C = decrease 1 °C , 1 Deg C = increase 1 Deg C
05 Temperature Readout
(AF mode only)
This gives you the option to show the Air Temp,
Floor Temp or to show both Air & Floor at intervals
A = Show Air Temperature
F = Show Floor Temperature
A-F = Show Floor and Air Temperature in 5 sec intervals
06 Maximum Floor Temp
( AF Mode only) This is to protect the floor surface 20 Deg C - 40 Deg C (40 Deg C by default)
07 Temperature Format This allows the temperature to be set to show
Deg Celsius or Deg Fahrenheit Deg C / Deg F
08 Clock Format You can select the clock to show in either 12
or 24 hour time 24 (default), 12- hour or 24-hour clock format
09 Frost Protection This is to avoid your room temp going below 5 DegC On = activated, Off = deactivated
10 5+2 / 7 Day mode
This allows you to programme either 5 days at once,
then the 2 days of the weekend separately,
or a full 7 days at the same time or 7 days separately.
01 = 5 + 2 Day Programming
02 = 7 Day Programming
HotwireThermostat
Technical Information
To enter into the setting menu please follow the steps below:
Step 1. Turn the thermostat off by pressing POWER
Step 2. Press MENU you will then see menu 01.
Step 3. Use the up and down arrows to adjust the sensor selecti on which is Menu 01(Air sensing;Air and Floor, or Floor only)
Step 4. Press NEXT to move to the next Menu and once you have all the menu options set,
Setp 5. Press DONE to accept and store.
Configuration Menu
HotwireThermostat
Instructions
Model Number: TR8100V
HotwireThermostat
Instructions
Turning your heating Off Manually:
Your thermostat and floor are both off and your floor will cool down. Any
settings you have entered into the Thermostat will be maintained
Australia
Verve Distribution
6 Todd St
Port Adelaide SA 5015
www.vervedistribution.com.au
New Zealand
The Heating Company
PO BOX 420
Whitianga NZ
www.hotwire.co.nz
Program button
Confirm button
Set the clock
Set the day of the week
7
8
6
5
4
3
2
1
RT stands for “room temperature” and FT stands for “floor temperature”.
Power button, to turn on/off the thermostat9
Manu
Auto
Indicates the time frames available in Auto Mode.
Heating is turned on
“Manu” indicates manual mode, “Auto” indicates automatic mode. In
Auto mode, the thermostat executes the preprogrammed schedules.
While in Manu mode, the thermostat maintains a constant set temperature
manually set by the user.
Button and Descriptions
RT/FT
1234
Press clock button, and time display will start flashing
Use the up and down buttons to adjust .Holding the
Press the OK button once the time is set.
Press the day button to get to the current Day of the week.
Step One: Set The Time and Day:
Turning your heating on and off Automatically
buttons down will increase or decrease the time in 15 minutes increments.
Ensure that the thermostat is on Auto mode.
Step Two: Set the thermostat to Auto mode
Turning your heating On Manually:
Press the up or down button to adjust to the required temperature
Around 23degC is an average but you can increase if required.
Press OK button to exit.
Step Three: Programming your schedules
If you set your thermostat to 7 day programmable mode
If you set your thermostat to 5+2 day programmable mode
(1). Press Prog button.
(3). Press up or down buttons to adjust the time you wish the program 1 event to commence
for the currently selected day. and then press Prog button.
(2). Press up or down buttons to select the day you wish to start programming. then press Prog.
(hold up button to select all days of the week, to cancel, hold up button again.)
(4). Press up or down buttons to set the temperature for this time period,then press Prog.
(6). Press OK to save and exit.
(8). Press OK to save and exit.
(5). Set time and temperature for the next time period. Repeat step(2) and (3) for each
time period.
(1). Press Prog button.
(2). Press up or down buttons to adjust the time you wish the program 1 event to commence
for the week days( from Monday to Friday). and then press Prog button.
(5). Press up or down buttons to adjust the time you wish the program 1 event to commence
for the weekends( Saturday and Sunday). and then press Prog button.
(3). Press up or down buttons to set the temperature for this time period,then press Prog.
(4). Set time and temperature for the next time period. Repeat step(2) and (3) for each
time period. and then press Prog button.
(6). Press up or down buttons to set the temperature for this time period,then press Prog.
(7). Set time and temperature for the next time period. Repeat step(5) and (6) for each
time period.
icon will display.
Key Lock & Unlock
Press and hold to unlock the thermostat. The lock icon will disappear.
* Note no program changes are possible while the unit is locked.
Press and hold to lock the thermostat. A lock
In Auto mode, to temporary override the current setpoint temperature,
1. Press up or down button once, the set temperature starts flashing.
2. Press up or down button again to adjust the set temperature.
3. Press OK button to confirm the setting with OVERRIDE shown.
Now your thermostat will maintain the new set temperature until the next setpoint.
To cancel the override setting, press Del button once.
Temporary temperature override
In standby mode(when thermostat is turned off), press and hold Clock button and
Your thermostat has the ability to reset all settings to the factory defaults. If you
are certain you want to do this:
Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)
Resetting factory defaults
MO
MO
To select Auto use the mode button
Press the power button to turn on your thermostat.
Press the ok button. The reading will return to the ambient temperature
Press Power button to turn off your thermostat, you will see OFF on LCD.
Press the Mode button until the screen shows manual.
AUSTRALIA
Hotwire Heating
WWW.HOTWIREHEATING.COM.AU
NEW ZEALAND
The Heating Company
www.theheatingcompany.co.nz/

HotwireThermostat
Instructions
Menu Settings
Press Power buttton to turn off the thermostat.
Press and hold button Prog for 3 seconds to bring up a configuration menu. Now press Prog button to select different menu number.
Set the temperature readout(AF model only). This gives option to choose to show air
A= to show air temperature,
A - F = to show both in 5 second intervals
temperature,floor temperature or to show both floor & air in interval.
01 = 5+2 day programmable
02 = 7 day programmable
LOAD (16A)
FEED
230 VAC
Floor Sensor
LL NPower Supply:
220Vac +10%, 50/60Hz
Load Capability: <16 A, 220VAC
Accuracy: 1deg C
Set-point range: ambient 5~30 deg C
floor 5~40 deg C
Storage: -20~50 deg C
Sensor selection. This thermostat is a combination model allowing you to choose
between 3 different models. (A, AF,F,)
Amodel: air only , with built in sensor
AF model: air & floor , with both built in and remote sensor
F model: floor onl y , with remote sensor
Menu #
1
Switching differential.
Calibrate the room temperature. This feature is used to compensate for any difference
Calibrate the floor temperature. This feature is used to compensate for any difference
Set the floor temperature limit(AF model only).
Select temperature format
Select 12 / 24 hour clock 24 12 / 24
2
3
4
5
6
7
8
9
10
Feature Description Factory Default
Feature Value
0°C
ON / OFF
OFF
01
40
A
°C 20°C ~40 °C
°C / °F
°C
A / AF / FA
Press up or down button to select
The numbers of degree difference before switching. The default is
between the displayed room temperature and a thermometer.
between the displayed floor temperature and a thermometer.
This feature is to protect the floor surface.
°C or °F.
Program type selection.
This gives user 2 options of program type.(5+2 or 7 day programmable)
5+2
day will give you 5 days(Monday to Fiday) with the same four events(Wakeup, out,
7 day will give you individual settings for each day from Monday to Sunday.
home,sleep) and 2 days(Saturday and Sunday) with the same four events.
Frost protection. This feature is to avoid room temperature goes below 5 °C
1°C which means the thermostat will switch the heating on 0.5°C below the set
temperature and will turn it off 0.5°C above the set temperature.
With a 2°C differential, the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
1°C 1°C ~ 5°C
-5°C ~ +5°C
0°C -5°C ~ +5°C
F=to show floor temperature,
Setting the clock and day of the week
This thermostat is fitted with a real time clock. It is essential that the clock time
and day are set accurately if you require your programmed events to start on
time. To set follow the steps below:
(1). Touch the time display and the time will start flashing. Use the up and down
arrows to set the time. By holding the arrow down the time will change
faster.
(2). Press NEXT to move to the Day setting and use the up and down arrows
to get to the correct day.
(2). Press DONE to store and exit.
Programme Start Time Setpoint Explanation
01 WAKE
07:00 22 °C This is the time the heating will
come on in the morning.
02 LEAVE
09:30 16 °C
This is the time the heating will
switch off in the morning. It can also
be used to set a minimum
temperature for the day.
03 RETURN
16:30 22 °C This is the time the heating will
come on in the afternoon.
04 SLEEP
22:30 16 °C
This is the time the heating will
switch off in the afternoon / evening.
If you do not require the heating in
the afternoon / evening, simply set
this time to a couple of minutes after
the “on” time.
Setting the Programme Schedules
This thermostat has the ability to programme each individual day of the week
separately, or programme 7 days of the week at once. You can also programme
weekdays (5 days) to one schedule and then weekends (2 days) to a different
schedule. See the Menu information for details on how to set this up.(refer to
Menu 10) See page 4 of this manual.
LCD symbols
The buttons are locked
Icon Legend
Heating is turned on
Frost protection activated
Programme number
Manual mode
Temporary temperature override
Automatic mode, executes the programmed schedulesAUTO
Err The floor sensor is not being read by the thermostat
Economy temperature
Comfort temperature
Override
Programming your Thermostat.
Default Programming is as follows.
(1). Press SCHEDULE and the day display will start flashing. Using the arrow to
select the day you wish to programme. Then press Next. (If your thermostat
is set to 5+2 day programmable mode, the programming will skip to step 3)
(7). Use and to adjust the time you wish the heating to switch off in
the morning on the selected day or days.
(8). Press NEXT and the temperature will start flashing. This can be used to
maintain a minimum temperature. In most cases this is not required and the
temperature should be set to 5.
This will help you programme your thermostat to come on and off automatically.
If you want to simply turn it on and off when required skip this section.
(9). Press NEXT and the 3icon will display. The time is also flashing. Set the
time at which you want the heating to come on in the afternoon or evening.
NOTE: If you do not wish the heating to come in the afternoon, simply
set the “off” time for only a couple of minutes after the “on” time.
(*). Hint: During setting programs, press DELETE will clear a programme entry and
thermostat will maintain the temperature setpoint of the last executed
programme until the beginning of the next programme.
(*). Hint: If you use the default programming of 5 week days plus 2 weekend
days you will now need to repeat the above steps for the weekend.
(11). Press NEXT and the LCD screen will show programme 4This is the time
that the thermostat will switch off in the afternoon / evening. Press NEXT
and set the temperature. As per above we recommend 5. Then Press DONE
(3). Press NEXT and is displayed. This is the first programme function of the day.
(10). Press NEXT and set the temperature required in the afternoon.
(6). The LCD screen will show programme 2( 2) and the time will be flashing.
This is the time that the thermostat will switch off in the morning.
(4). The time is now flashing. Select the time you want the heating to come on
in the morning. Then press next.
(5). The temperature is now flashing. Set the temperature that you want the floor
to heat to. Then press next.
(2). To select every day to be the same simply press All Days.
HotwireThermostat
Instructions
Menu Settings
Press Power buttton to turn off the thermostat.
Press and hold button Prog for 3 seconds to bring up a configuration menu. Now press Prog button to select different menu number.
Set the temperature readout(AF model only). This gives option to choose to show air
A= to show air temperature,
A - F = to show both in 5 second intervals
temperature,floor temperature or to show both floor & air in interval.
01 = 5+2 day programmable
02 = 7 day programmable
LOAD (16A)
FEED
230 VAC
Floor Sensor
LL NPower Supply:
220Vac +10%, 50/60Hz
Load Capability: <16 A, 220VAC
Accuracy: 1deg C
Set-point range: ambient 5~30 deg C
floor 5~40 deg C
Storage: -20~50 deg C
Sensor selection. This thermostat is a combination model allowing you to choose
between 3 different models. (A, AF,F,)
Amodel: air only , with built in sensor
AF model: air & floor , with both built in and remote sensor
F model: floor onl y , with remote sensor
Menu #
1
Switching differential.
Calibrate the room temperature. This feature is used to compensate for any difference
Calibrate the floor temperature. This feature is used to compensate for any difference
Set the floor temperature limit(AF model only).
Select temperature format
Select 12 / 24 hour clock 24 12 / 24
2
3
4
5
6
7
8
9
10
Feature Description Factory Default
Feature Value
0°C
ON / OFF
OFF
01
40
A
°C 20°C ~40 °C
°C / °F
°C
A / AF / FA
Press up or down button to select
The numbers of degree difference before switching. The default is
between the displayed room temperature and a thermometer.
between the displayed floor temperature and a thermometer.
This feature is to protect the floor surface.
°C or °F.
Program type selection.
This gives user 2 options of program type.(5+2 or 7 day programmable)
5+2
day will give you 5 days(Monday to Fiday) with the same four events(Wakeup, out,
7 day will give you individual settings for each day from Monday to Sunday.
home,sleep) and 2 days(Saturday and Sunday) with the same four events.
Frost protection. This feature is to avoid room temperature goes below 5 °C
1°C which means the thermostat will switch the heating on 0.5°C below the set
temperature and will turn it off 0.5°C above the set temperature.
With a 2°C differential, the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
1°C 1°C ~ 5°C
-5°C ~ +5°C
0°C -5°C ~ +5°C
F=to show floor temperature,
Installation and Wiring
Carefully separate the front half of the thermostat from the back plate by placing a
small flat head terminal driver into the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged into the front half of
the thermostat. Place the thermostat front half somewhere safe. Terminate the
thermostat as shown in the diagrams below.
Screw the thermostat back plate onto the flush box
Re-connect the thermostat ribbon cable and clip the two halves together.
Installation Instructions
Figure 1: When Installing the product in a flush box the minimum dimensions as
shown in Figure 2 and Figure 3 should be followed (ie a minimum clearance of 5
mm around all of the sides).
LOAD (16A)
FEED
(230VAC)
Floor Sensor
This product should be installed by
a qualified electrician.
LL NN
Installation Instructions
Figure 1
Figure 1: When Installing the product in a flush box (as shown above) the minimum
dimensions as shown in Figure 2 and Figure 3 should be followed (ie a minimum clearance
of 5 mm around all of the sides).
Figure 2
Figure 3
Installation Instructions
Figure 1
Figure 1: When Installing the product in a flush box (as shown above) the minimum
dimensions as shown in Figure 2 and Figure 3 should be followed (ie a minimum clearance
of 5 mm around all of the sides).
Figure 2
Figure 3
Installation Instructions
Figure 1
Figure 1: When Installing the product in a flush box (as shown above) the minimum
dimensions as shown in Figure 2 and Figure 3 should be followed (ie a minimum clearance
of 5 mm around all of the sides).
Figure 2
Figure 3
Holiday Function
Temporary Temperature Override
With thermostat turned off, press and hold OFF for 5 seconds until you can
see -- : -- on LCD.
Manual Mode
Press MODE to select Auto/Manual mode. In Manual mode( ), the
thermostat maintains a constant set temperature manually set by the user.
Simply press the temperature and increase it to the required level.
In Auto mode, the thermostat executes the preprogrammed schedules.
The Holiday function reduces the temperature in your room to the frost
protection temperature. The thermostat will maintain this temperature for the
duration of the holiday and will then automatically return to the programme
mode on your return.
Touch the temperature display, and it will start to flash. Use up or down buttons
to adjust. Press DONE to accept, and you will see “Override” above the
temperature display. Thermostat will maintain the new set temperature until the
next programmed event (comfort level). To cancel the override setting, press
Run Schedule
Press HOLIDAY enter the duration of your holiday by or or
Press DONE To cancel a Holiday, reduce the holiday period to 00 days.
Lock the Keypad
To lock the keypad, press and hold the top left corner of display for 5 seconds,
you will see a lock symbol . To unlock, repeat the steps above and the lock
symbol will disappear.
Reset to Factory Setting
Other HotWire Thermostat manuals

HotWire
HotWire TR8100 DUAL Control User manual

HotWire
HotWire HWGL1 User manual

HotWire
HotWire HWTH1 User manual

HotWire
HotWire T888 User manual

HotWire
HotWire RDE20.1 Troubleshooting guide

HotWire
HotWire TR8100V User manual

HotWire
HotWire HWGL2 User manual

HotWire
HotWire HWSMWiFil User manual

HotWire
HotWire Wireless Glass TR8100V User manual

HotWire
HotWire HWTH1 User manual