manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HP
  6. •
  7. Storage
  8. •
  9. HP StorageWorks P4000 Series User manual

HP StorageWorks P4000 Series User manual

Other manuals for StorageWorks P4000 Series

17

This manual suits for next models

1

Other HP Storage manuals

HP StorageWorks Modular Smart Array 500 System User manual

HP

HP StorageWorks Modular Smart Array 500 System User manual

HP StorageWorks NAS 1000s User manual

HP

HP StorageWorks NAS 1000s User manual

HP 6100 Guide

HP

HP 6100 Guide

HP 157770-001 - DAT Drive 20/40 Tape User manual

HP

HP 157770-001 - DAT Drive 20/40 Tape User manual

HP StorageWorks 1000 - Modular Smart Array User manual

HP

HP StorageWorks 1000 - Modular Smart Array User manual

HP P9000 User manual

HP

HP P9000 User manual

HP 157770-001 - DAT Drive 20/40 Tape Instruction Manual

HP

HP 157770-001 - DAT Drive 20/40 Tape Instruction Manual

HP AH164A - StorageWorks 1/8 G2 Tape Autoloader Ultrium... User manual

HP

HP AH164A - StorageWorks 1/8 G2 Tape Autoloader Ultrium... User manual

HP StorageWorks XP12000 User manual

HP

HP StorageWorks XP12000 User manual

HP StorageWorks 600 - Modular Disk System User manual

HP

HP StorageWorks 600 - Modular Disk System User manual

HP DW017B - StorageWorks Ultrium 448 Tape Drive User manual

HP

HP DW017B - StorageWorks Ultrium 448 Tape Drive User manual

HP StorageWorks TL895 User manual

HP

HP StorageWorks TL895 User manual

HP StorageWorks X5000 Instruction Manual

HP

HP StorageWorks X5000 Instruction Manual

HP 3000 - 37XE System Instruction Manual

HP

HP 3000 - 37XE System Instruction Manual

HP P9000 User manual

HP

HP P9000 User manual

HP P700 User manual

HP

HP P700 User manual

HP StorageWorks P4000 Series Operating manual

HP

HP StorageWorks P4000 Series Operating manual

HP StorageWorks XP12000 User manual

HP

HP StorageWorks XP12000 User manual

HP StorageWorks XP10000 - Disk Array User manual

HP

HP StorageWorks XP10000 - Disk Array User manual

HP D5970A - NetServer - LCII Operator's manual

HP

HP D5970A - NetServer - LCII Operator's manual

HP C450W User manual

HP

HP C450W User manual

HP XP7 User manual

HP

HP XP7 User manual

HP Surestore Tape Library Model 3/30 Manual

HP

HP Surestore Tape Library Model 3/30 Manual

HP Model 744 - VME Workstation Reference guide

HP

HP Model 744 - VME Workstation Reference guide

Popular Storage manuals by other brands

IBM 40/80 GB HH DLTVS user guide

IBM

IBM 40/80 GB HH DLTVS user guide

Synology DiskStation DS716+II Quick installation guide

Synology

Synology DiskStation DS716+II Quick installation guide

Vantec NexStar-HX4 user manual

Vantec

Vantec NexStar-HX4 user manual

LaCie Christofle Galet datasheet

LaCie

LaCie Christofle Galet datasheet

LaCie Rugged Thunderbolt user manual

LaCie

LaCie Rugged Thunderbolt user manual

OCZ IBIS datasheet

OCZ

OCZ IBIS datasheet

Transcend JetFlash 110 Brochure & specs

Transcend

Transcend JetFlash 110 Brochure & specs

QNAP TS 32PXU Series user guide

QNAP

QNAP TS 32PXU Series user guide

LaCie RUGGED RAID user manual

LaCie

LaCie RUGGED RAID user manual

Freecom CLS DOCK Quick install guide

Freecom

Freecom CLS DOCK Quick install guide

PNY Attache P-FD64MBATT3 install guide

PNY

PNY Attache P-FD64MBATT3 install guide

OWC Mercury Elite Pro Dual mini Assembly manual

OWC

OWC Mercury Elite Pro Dual mini Assembly manual

OLT 6x6 Maximizer Assembly manual

OLT

OLT 6x6 Maximizer Assembly manual

Transcend JetFlash 160 Specifications

Transcend

Transcend JetFlash 160 Specifications

Thunderbolt 600 user manual

Thunderbolt

Thunderbolt 600 user manual

Intel RAID High Availability user guide

Intel

Intel RAID High Availability user guide

LaCie 12big Thunderbolt 3 Quick install guide

LaCie

LaCie 12big Thunderbolt 3 Quick install guide

Spectra Logic T-Series Spectra T50e quick start guide

Spectra Logic

Spectra Logic T-Series Spectra T50e quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

HP P4800 G2 SAN Solution for BladeSystem
Quick Start Guide
*BV931-96001* Printed in Puerto Rico
Step 1 Setting up the storage system
Step 2
Documentation Available
For links to the latest manuals for HP BladeSystem and other P4800 G2 components, see the HP P4800 G2 SAN Solution for BladeSystem Documentation CD.
For detailed instructions about using and maintaining the HP P4800 G2 SAN Solution for BladeSystem, see the following resources:
•Online Help
Click Help > Help Topics from the menu bar to open the Online Help. Context-sensitive help is available by clicking the question mark on any window.
•HP P4000 SAN Solution User Guide
Find complete instructions for configuring and managing storage systems and clustered storage volumes in the User Guide. The User Guide is available in PDF format, installed in the
same directory as the Centralized Management Console program files.
•HP P4800 G2 SAN Solution for BladeSystem Maintenance Guide
Find detailed instructions for managing and maintaining the HP P4800 G2 SAN Solution for BladeSystem.
•HP P4000 VSA Installation and Configuration Guide
Find detailed instructions for planning and installing the VSA and getting started with the Centralized Management Console.
• HP P4000 Remote Copy User Guide
Find information about configuring and using asynchronous replication of storage volumes and snapshots across geographic distances.
• HP P4000 Multi-Site HA/DR Solution Pack User Guide
Find detailed instructions for designing and implementing the Multi-Site SAN features to synchronously and automatically mirror data between geographic sites.
• Release Notes
Review the Release Notes for the latest information about the product.
The latest versions of these documents, including localized versions can be found by browsing to http://www.hp.com/support/manuals. Click Disk Storage Systems
in the storage section and then select the product HP P4000 G2 SAN Solution.
For detailed configuration information related to P4800 G2 use in VDI configurations, see the HP Converged Infrastructure Reference Architecture for VMware View at
http://www.hp.com/go/vdi.
Support Contacts
For worldwide technical support information, see the HP support website: http://www.hp.com/support.
Note
The HP P4800 G2 solution is available as a fully factory-integrated system or as a field installation. For the factory-integrated system, begin with step 1.
For the field installation, an HP Service Engineer will integrate the solution onsite and you can disregard the rest of this guide.
Example of a two node configuration. Connect a network cable from the OA on the blade enclosure to your manage-
ment network.
Connect the system power cord to the site power source. The blade enclosure
powers on automatically.
Connect at least one cable from each Flex-10 module to the management
network.
From the Insight Display assign a network address or allow DHCP address
assignment to the enclosure.
Log in to the OA from a web browser using the administrator username and
password located on the asset tag of the OA.
Using the OA virtual power buttons, power down the SAS switches and Flex-10
modules. Then reapply power in the following sequence:
1. Disk enclosure
Press the power button on the back of each disk enclosure. Wait three
minutes.
2. SAS Switches
Use the OA to power on the SAS switches. Wait one minute.
3. Flex-10 Modules
From the OA, power on the Flex-10 modules.
4. Server blades
One minute after powering on the SAS switches, power on the P4460sb
G2 server blades.
The remaining steps can be completed remotely.
Use the OA to configure the local enclosure.
Open the Virtual Connect Manager from the OA and log in using the
administrator username and password located on the asset tag of the active
Flex-10 module.
Configure the Virtual Connect domain and define a network for the iSCSI
traffic. For user information, see the HP Virtual Connect for c-Class
BladeSystem User Guide on the HP P4800 G2 BladeSystem SAN Solution
Documentation CD
For an example of how to isolate iSCSI traffic within the enclosure, skip the rest of
this guide and continue with the HP Converged Infrastructure Reference Architecture
for VMware View (http://www.hp.com/go/vdi).
1
2
3
4
5
7
1. Blade enclosure
2. P4460sb G2 Server blades
3. Insight Display
4. Disk enclosure
5. Flex-10 modules
6. SAS switches
7. Onboard Administrator (OA)
8. Disk enclosure power button
1
2
3
4
5
6
Front Back
8
SAS switch - Disk enclosure connections
7
8
9
Step 2 Configuring the network interface
Step 3 Setting up the SAN
Using the Onboard Administrator:
For each P4460sb G2 node, connect to the iLO Integrated Management Console
and complete the following instructions.
Prerequisites
Before configuring the network settings on individual storage systems, have the
following information ready:
• Host names
• IP addresses, subnet mask and gateway.
Logging into the configuration interface
Press enter to log in. Use the tab key to move through the fields and menu
options in the configuration interface.
Configuration interface main menu
Tab to network TCP/IP settings and press enter.
Selecting an interface to configure
Tab to select the network interface that you want to configure (eth0 or port1)
and press enter.
Change the host name and set IP address
Set the IP address, subnet mask and gateway.
Best practice
Manually assign IP addresses to the storage systems. Using DHCP to obtain an
IP address is not recommended unless using reserved addresses.
Verify IP address
Ping the IP address of the storage system from another host on the network to
verify that it is operating correctly.
Repeat for each storage system.
Using the HP P4000 Management Software for Microsoft Windows DVD:
Insert the DVD in the DVD drive. The installer should launch automatically.
Installing the centralized management console (CMC)
Install the CMC on the computer that you will use to administer the SAN. You
need administrative privileges while installing the CMC.
Using the installation wizard:
1. Click Centralized Management Console.
2. Click Install CMC.
3. Continue through the installation wizard, following the instructions on
each window.
Install the Failover Manager
Install the Failover Manager onto a separate server on the network.
Caution: Do not install the Failover Manager on the P4800 G2
BladeSystem SAN, since this would defeat the purpose of the Failover
Manager.
Using the installation wizard:
1. Click Failover Manager.
2. Click Install FOM.
3. Continue through the installation wizard, following the instructions on
each window.
4. Click Finish to exit the wizard and start the Failover Manager.
Discover storage systems on the network
Use Find Systems to discover the storage systems on the network, using either
IP addresses or Auto discover by broadcast checkbox.
The found storage systems appear in the Available Systems category in the
CMC.
Verify or configure RAID and configure network settings
Verify the RAID configuration on your storage systems before creating a
management group. You can only reconfigure RAID on storage systems that
are in the Available Systems pool. Change network settings, including
bonding NICs, before creating a management group.
Verify software version is up to date
Use the “Check for Updates” to update your software to the latest version.
Setting up SAN storage
Use the management groups, clusters and volumes wizard to set up the
storage configuration and create a storage volume.
Download and install iSCSI initiator(s)
Install the appropriate iSCSI initiator on your application servers.
Enable access to volumes
Use the Assign Volume and Snapshot wizard to prepare the volume for
server access. You set up application servers in the management group, and
then assign volumes to the servers.
Log in to volumes via iSCSI initiator(s)
Configure the initiator(s) to ...
• Connect to the cluster VIP.
• Discover the targets.
• Log on.
• Format the disks with a file system.
Next Steps:
• Check the Alarms panel and resolve any alarms.
• Check the Best Practices Analyzer under the Configuration Summary.
1
2
4
6
7
8
9
10
3
5