HOW TO USE
Connect the clamps/eyelets
to the charger and to your
battery.
Plug the charger into
an electrical outlet.
Select the appropriate charge
mode for your battery.
Press Confirm button or
wait 10 seconds to start the
charging process.
BUTTON OPERATION
STEP 1
BUTTON OPERATION
STEP 1 STEP 3 STEP 4
Press to cycle through "12V, 12V AGM, 12V Lithium, 6V, 6V AGM" modes.
Press & hold for 2 seconds to enter “12V Repair” mode.
Press & hold for 1 second to go back to "Standby" mode when charging.
Press & hold for 1 second to go back to "Standby" mode when is flashing.
Press it to start the charging process.
ERROR INDICATIONS
ICON SOLUTIONREASON
1.) Charger will automatically resume
function once the it's internal temperature
drops to -4°F~104°F.
1.) Charger internal temperature is too high.
2.) Charger ambient temperature is too low.
Battery voltage is too high for the selected charge mode.
Reverse Polarity
Bad Battery
Reverse the battery clamps/eyelets.
Check the battery and confirm the appropriate charge
mode for your battery.
2.) Charger will automatically resume
function once the it's ambient temperture
rises to -4°F~104°F.
1.) Connect the positive (red) clamp/eyelet terminal
connector to the positive (POS,P,+) battery terminal.
2.) Connect the negative (black) clamp/eyelet terminal
connector to the negative (NEG,N,-) battery terminal.
Battery will not hold a charge. Get the battery checked
by a professional.
Menu Button
Confirm Button
USER GUIDE
Sigma 1 Battery Charger

DISPLAY & OPERATION
7 CHARGING MODES
ICON EXPLANATIONRELATED MODE
In Standby mode, the charger is not charging or providing any power to the battery.Standby
For charging 12-volt Wet Cell, Gel Cell, Enhanced Flooded,
Maintenance-Free and Calcium batteries.
12V
For charging 12-volt AGM batteries.12V AGM
For charging 12-volt Lithium batteries.12V Lithium
For charging 6-volt Wet Cell, Gel Cell, Enhanced Flooded,
Maintenance-Free and Calcium batteries.
6V
For charging 6-volt AGM batteries.
An intelligent battery recovery mode for repairing and restoring sulfated, old, idle, damaged,
or stratified 12-volt batteries.
For charging 12-volt lead-acid batteries with a low voltage between 0.3V and 2V.
6V AGM
12V Repair
12V Loading
(Force mode)
Display Screen
Confirm ButtonMenu Button
ICON EXPLANATION
In "12V, 12V AGM, 12V Lithium, 6V, 6V AGM, 12V Loading" mode, this icon Indicates the connected battery level.
The four bars from bottom to top indicate battery levels from 25% to 100%.from 25% to 100%.
The Sigma 1 has seven (7) charging modes: 12V, 12V AGM, 12V LITHIUM, 6V, 6V AGM, 12V Repair and 12V Loading (Force mode).
It is important to understand the differences and purpose of each charge mode. Please always check with battery manufacturer to confirm the right charge mode
for your specific battery. Do not operate the charger until you confirm the appropriate charge mode for your battery. Below is a brief description:
In "12V Repair" mode, these four bars from bottom to top indicate a repair time of 1h to 4h.
Flashing bars change to constant bars when the most recent stage is completed.
Battery Voltage. This icon indicates the voltage of the connected battery.
Battery Level or Repair Time.

CHARGING TIMES
CAUTION
TIME (HOURS-H)
BATTERY SIZE
(AMP HOURS-AH) 6V
4
8
12
20
32
4
8
12
20
32
3
6
9
15
18
3
6
9
15
18
12V 6V 12V
4Ah
8Ah
12Ah
20Ah
32Ah
EMPTY BATTERY TO 80% CHARGE 50% DOD BATTERY TO FULL CHARGE
TECHNICAL SPECIFICATIONS WHAT'S INCLUDED
WARRANTY
This HULKMAN product carries a 3-year hassle-free warranty
against defects in material and workmanship under normal use
starting from the date of purchase. In order to keep the warranty
valid, this product must be handled as described in this manual.
CONTACT HULKMAN
ADDRESS: 4500 Great America Pkwy, Suite 100 #110
Santa Clara, California 95054
TEL: +1 (877) 892-9703
EMAIL: [email protected]
WEBSITE: www.hulkman.com
Input Voltage AC: 100-240VAC, 50-60Hz, 20W
Output: 6/12VDC, 1A
Back Current Drain: 1.5mA
Operating Temperature: -4°F to +104°F
Storage Temperature: -40°F to +140°F
Type of Batteries: 6V/12V Lead-Acid & 12V Lithium
Battery Capacity: Up to 32Ah, maintains all battery sizes
Ingress Protection: IP60
Dimensions (L x W x H) : 3.9 x 2.4 x 1.6 inches
Weight: 0.89 pounds
HULKMAN Sigma 1
Battery Charger
Battery Clamps
Battery Eyelets
21 inches
21 inches85 inches
User Manual & Warranty Card
12V Repair can take up to four (4) hours to complete the recovery process and for use on 12-volt lead-acid batteries with a voltage higher than
2V only. Please note that not all batteries can be recovered. The effectiveness of the repair will depend greatly on the degree of damage to the
battery. In general, the more severe the damage to the battery, the more difficult, if not impossible, the repair will be.
When the connected battery's voltage is between 0.3V and 2V, and the 12V, 12V AGM or 12V Lithium mode is selected, this icon will flash
automatically. Press the Confirm button to enter a 5-minute force charge. (It can only be activated by pressing Confirm button)
USING 12V REPAIR
USING 12V LOADING