Hunter 33202 User manual

SINCE 1886
The Care-Free
Humidifier Plus
Evaporative Humidifier
Models 33201 & 33202
www.hunterfan, corn
41553-01 5/1012002 1 © 2002 HUNTER FAN CQ.

.
,
.
Important Safety Insn ctions:
Read all instructions before
using this humidifier.
This humidifier may not work properly
on an uneven surface. ALWAYS place
this humidifier on a firm, level, and wa-
ter resistant surface. ALWAYS place the
humidifier at leastsix (6) inches away from
walls and heat sources such as stoves,
radiators, or heaters.
ALWAYS place the humidifier in an area
that is out of the reach of children.
Before using the humidifier, extend the
cord and inspect for any signs of dam-
age. DO NOT use the product if the cord
has been damaged.
This product has a polarized plug (one
blade is wider than the other) as a safety
feature. This plug will fit into a polarized
outlet only one way. If the plug does not
fit fully into the outlet, reverse the plug.
,
.
If it still does not fit, contact a qualified
electrician. DO NOT attempt to defeat
or override this safety feature.
ALWAYS UNPLUG AND EMPTY the hu-
midifier when it is not in operation or
while it is being cleaned.
DO NOTtitt or move the humidifier while
it is in operation. Never move 'the hu-
midifier while there is water in the tank.
Empty the water tank, turn off, and un-
plug the unit before moving.
In addition to routine maintenance which
may be required, this humidifier requires
seasonal cleaning. Refer to and follow
CLEANING THE HUMIDIFIER AND THE
WATER TANK instructions.
Thank you for purchasing The Care-Free
Humidifier PlusTM Evaporative Humidifier
by Hunter Fan Company. Please read
and save these instructions to receive the
maximum benefit and performance from
your humidifier.
How The Care-Free Humidifier PlusTM
Evaporative Humidifier Works
The Care-Free Humidifier PlusTM Evaporative
Humidifier has a unique patented design with
several innovative features:
Low Maintenance- Other humidifiers have
paper filters that need to be replaced every
few months. Our exclusive PermaWick TMfil-
ter saves time and money. It's designed to
last season after season, saving up to $45 a
year. No wet paper odors either.
Regulated Release TM System -By dis-
persing water from the top of the
PermaWick TMfilter, stagnant water around
timePermaWick TM filter is eliminated, and
the buildup of mineral residue that can
clog the filter and impede performance
is eliminated. NOTE: Timefilter has a coat-
ing on the wick which may make it appear
old or used, but is actually new.
Built-in Antimicrobial Properties - The
plastic parts and the PermaWick TM filter
have built-in antimicrobial properties to in-
hibit the growth of bacteria, mold and
fungi that may affect these parts.
NOTE: This product contains antimicrobial
properties which are built-in to inhibit the
growth of bacteria which may affect the
plastic and PermaWick TM filter in the hu-
midifier. These properties do not extend to
the water, humidified air or users. Conduct
routine cleaning and maintenance based
upon use and individual conditions.
41553-01 5/1012002 2 @ 2002 HUNTER FAN CO.

No White Dust -The Care-Free Humidi-
fier PlusTMEvaporative Humidifier produces
no white dust that can settle on furniture
or be inhaled.
NOTE: You may notice mineral deposits
accumulating in 'the tank base o1 on the
PermaWick TM filter, This is normal and
does not affect performance, If you
would like to clean these deposits away,
please see CLEANING THE HUMIDIFIER
AND WATERTANK.
Humidifier Parts
Power Light or NlteGlo TM
Night Light Control Main Housing
Inlet Grill
Easy Tote Handle
Water Tank
Base Wick Supports
41553-01 511012002 © 2002 HUNTER FAN CO.

Humidifier Features
Power Light (Some Models): The light will be
illuminated when the power is on .....
Fan Power/Speed Control: Turns the
humidifier 'ON' and 'OFF'. The power should
always be off before unplugging the
humidifier, moving the humidifier, or refilling
the water tank.
NiteGIo ri Night Light Control (Some
Models): Turns the night light 'ON' and 'OFF'.
The night light can be turned on even if the
humidifier fan is turned off.
Power Light or
NlteGto TM
Night Light Control
Power ISic
Control
Figure 2
1
,
.
S.
Using Your Humidifier
Remove The Care-Free Humidifier PlusrM
Evaporative Humidifier from its packaging.
Readand Savethe Instructions.
Place the humidifier on a hard, flat, water
resistant surface. AIways place the humidi-
fier at leastsix(6) inches away from walls and
sources of heat.
Lift the main housing to confirm that the
PermaWickTM filters are placed upright in the
slots. Replacethe main housing. (SeeFigure 1.)
Remove the water tank and take it to the
sink or tub to fill.
Turn the tank upside down and unscrew the
tank cap by turning it counterclockwise. Fill
the water tank with cool water and replace
the tank cap (Never use hot water). Be sure
not to overfill the tank as water damage may
occur to furniture or flooring due to spillage.
,Carry the tank back to the humidifier. Turn
the tank upright and place it on the humidi-
fier. Be sure that the tank is seated properly
in the base. If the tank is properly located on
the base, you will see air bubbles flowing up
into the tank.
,With the power control knob in the 'OFF' po-
sition, plug the humidifier into the wall.
CAUTION: Never plug in the Humidifier
while your hands are wet as Electric Shock
could occur.
8. Use the power control knob to turn the
humidifier 'ON' by selecting a speed set-
ting.
Only for models with a NiteGIo TM night light
9. Use the control to turn the night light off
and on. The night light can be operated
even if the humidifier fan is turned 'OFF'.
HUNTERWILLNOTACCEPTRESPONSIBILITYFOR
DAMAGE TO PROPERTYCAUSED BY WATER
SPILLAGE.
41583-01 5110/2002 4 © 2002 HUNTER FAN CO,

Refilling The Water Tank
1. When the water tank level is low, turn the
humidifier 'OFF', and unplug.
2. Remove tile tank and take it to the sink or
tub to refill.
3. Turnthe tank upside down and unscrew the
tank cap by turning it counterclockwise.
Empty tile tank, refill with fresh cool water
(never use hot. water), and replace the tank
cap. Besure not to overfill tile tank as water
damage may occur to furniture or flooring
due to spillage.
,
HUNTERWILL NOT ACCEPT RESPONSIBIL-
ITY FOR DAMAGE TO PROPERTY CAUSED
BY WATERSPILLAGE,
Carry the tank back to the humidifier. Turn
the tank upright and place it on the hu-
midifier. Be sure that the tank is seated
properly in the base. If the tank is properly
located on the base, you will see air bubbles
flowing up into the tank.
.....Cleaning The Humidifier And. The Water Tank
Many regions have hard water with high
concentrations of minerals. When water
evaporates from The Care-Free Humidifier
PlusTMEvaporative Humidifier, minerals may be
left behind. These minerals can form a hard
white scalewhich can be removed by following
the cleaning instructions. The frequency of
cleaning due to mineral build up can vary
depending upon the quality of water you
may have.
Refer to Figure 1 for part names.
1. Turn the humidifier 'OFF' and unplug the
unit.
2. Lift the main housing and remove the wa-
ter dispersion tray and the PermaWick TM
Filters,The motor is attached to the main
housing, Do not place the motor near
water. Do not use a wet towel on the
motor or motor housing as electrical
shock may occur,
3. The PermaWick TMFilter should be cleaned
in a vinegar and water solution to remove
any mineral buildup. Place in a solution of
one (1) gallon of water and eight (8) ounces
of undiluted white vinegar. Allow the filter
to soak for 20 minutes.
4. After soaking, rinse it several times with
clean water. Place the PermaWick TMFilter
,
.
B,
,
in a location where it can drip dry while
you clean the other parts of your humidifier.
Remove the water tank from the base and
empty any water that is left in the tank.
Soak the base in a mixture of one (1) gal-
lon of water and eight (8) ounces of vin-
egar for 20 minutes.
After soaking, wipe the base with a soft
cloth or sponge to remove any mineral
build up. Rinse with clean water several
times. If you are planning on storing the
humidifier, be sure the base is com-
pletely dry.
Fill the water tank with one (1) gallon of
water and eight ounces of undiluted white
vinegar. Replace the tank cap and shake
the tank vigorously until all interior sur-
faces of the tank have been exposed to the
water/vinegar mixture.
Empty the tank of the water/vinegar mix-
ture. Rinse it several times with clean water
and then replace the tank cap. If you are
planning on storing the humidifier, dry it
inside and out, leaving the cap off to allow
the tank to completely dry. Continue to
clean the other parts of your humidifien
Remove the water diffuser cap and sponge.
Rinse the sponge in clean water to remove
any debris. If the sponge contains hard
41553-01 5110/2002 © 2002 HUNTER FAN CO,

water residue, soak it in a mixture of
one (1) gallon of water and eight (8)
ounces of vinegar for 20 minutes. Rinse
well and reinstall sponge and diffuser cap
in unit. Do not expose motor or other
electrical components to water,
10. Wipe the surfaces of the main housing with
a soft cloth.
11. Once all the parts are clean, reas-
semble the humidifier, and follow the
USING YOUR HUMIDIFIER to con-
tinue use. If you are storing the hu-
midifier, make sure the parts are
completely dry, reassemble, and
store in a dry location.
Service Parts
To obtain a service part for your humidifier, call customer service at !-888-830-1326 or e-mail us
your humidifier and the name of the part you need to replace. Refer to Figure 1 for part names.
Other Home Comfort Products from Hunter
g _ .i./,\
Hunter Original® QuietFlo _M
Ti:ueHEPA Air
Purifier
Programmable
Thermostat
To learn more about Hunter Fan Company products, please see our web page at:
www.hunterfan.com
41_g8-01 5t10/2002 © 2002 HUNTER FAN 00.

Hunter Fan Company
The Care-Free Humidifier Plu.ssM Evaporative
5 YEAR LIMITEDWARRANTY Humidifier
The Hunter Fan Company, Inc. makes the
following warranty to the original residen-
tial user o1:consumer p_rehaser of The Care-
Free Humidifier P]usr_aEvaporative Hu-
midifier:
If any pall:of The Care-Free Hmnidifier Plus TM
Evaporative Humidifier ("I-Iumidifier") mo-
tor fails during the first 5 (five) years fiom the
date of installation due to a defect in mate-
rial or workmanship, we will provide a re-
placement part free of charge. If no replace-
ment part can be provided for such motor, we
will replace yore" humidifier.
If your Humidifier motor fails any time
within 1 (one) year after the date of instal-
lation due to a defect in material or work-
manship, labor to repair the defect will be
provided fiTeeof charge at our nearest ser-
vice centre or at our Service Department in
Memphis, Tennessee. You will be respon-
sible for all parts and labor costs after this
one-year period.
Ifyour Humidifier water tank, filter fame, base,
knobs, or tank cap fail any time within 1 (one)
year after the date of sale to you due to a
defect in material or workmanship, we will
repair or, at our option, replace the water tank,
filter frame, base, knobs, or tank cap free of
chm'gefor parts or labor performed at our near-
est service centre or our Service Department
in Memphis, Tennessee.
1FTIlE ORIOINAL RESIDENTIAL USER OR
CONSUMER PURCHASER CEASES TO
OWN THE ItUMIDIFIER, THIS WARRAN]T
AND ANY IMPLIED WARRANTY WHICH
THEN REMAINS IN EFFECT, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR
FITNESS FORA PARTICULAR PURPOSE,
AREVOIDED.
NO WARRANTY, EXPRESSED OR IM-
PLIED, INCLUDINGANY WARRANTY OF
MERCHANTABILITY OR FITNESS FORA
PARTICULAR PUP,POSE, IS MADE IN RE-
SPECT TO THE FILTER.
THIS WARRANTY IS IN LIEU OF ALL
OTI-IER E_RES S W_TIE S, TI.qiEDU-
RATION OF ANY IMPLIED WARRANTY,
INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANT-
ABILITY OR FITNESS FORA PARTICULAR
PURPOSE, IN RESPECT TO THE MOTOR
IS EXPRESSLY LIMITED TO THE PERIOD
OF THE EXPRESS WARRANTY SET
FORTHABOVE.
This warranty is voided if your Hmnidi-
fier is not purchased and used in the USA
or Canada.
This warranty excludes and does not cover
defects, malfunctions, or failures of the Hu-
midifier which were caused by repairs by per-
sons not authorized by us, use of parts, or
accessories not authorized by us, mishan-
dling, modifications, or damage to the Hu-
midifier while in your possession, or unrea-
sonable use, including failure to provide rea-
sonable and necessary maintenance. This
warranty does not cover humidifiers used in
commercial applications. There are no express
or implied WalTanties as to commercial pur-
chasers or users.
To obtain service, contact the nearest Hunter
authorized service centre or the Hunter Fan
Company Service Departmem, 2500 Frisco
Avenue, Memphis, Tennessee 38114, 901-
248-2222. You will be responsible for insur-
ance and freight or other transportation to
our factory service center. We will return the
Humidifier freight prepaid to you. The Hu-
midifier should be properly packaged to
41553+0'_ 511012002 7 @ 2002 HUNTER FAN CO.

avoid damage in transit since we will not be
responsible for any such damage. Proof of
purchase is required when requesting war-
ranty service. The purchaser must present the
sales receipt or other document that estab-
lishes proof of purchase,
IN NO EVENT SHALL HUNTER FAN COM-
PANY BE LIABLE FOR DIRECT, INDIRECT.,
SPECIAL, CONSEQUENTIAL OR INCIDEN_
TAL DAMAGES 1NEXCESS OF THE PUR-
CHASE PRICE OF THE FJUMIDIFIER. YOUR
SOLE REMEDY WILL BE REPAIR OR RE-
PLACEMFMTAS PROVIDED ABOVE.
SOME AMERICAN STATES AND CANA-
DIAN PROVINCES DO NOT ALLOW
, LIMITATIONS ON HOW LONG AN
IMPLIED WARRANTY LASTS;
. THE EXCLUSION OR LIMITATION
OF DIRECT, INI)H_CT, SPECIAL, IN-
CIDENTAL OR CONSEQUENTIAL
DAMAGES;
• THE EXCLUSION OR INVALIDITY
OF EXPRESS OR IMPLIED WARRAN-
TIES IF THE USER CEASES TO OWN
THE HUMIDIFIER;
• THE LIMITATION OF THE REM-
EDIES AND RECOURSES AVAIL-
ABLE TO THE PURCHASER; OR
• THE INVALIDITY OF AN EXPRESS
WARRANTY WHEN A PRODUCT
IDENTIFIED BY BRAND NAME IS
NOT USED (UNLESS SPECIFIC CON-
DITIONS ARE FULFILLED);
SO THE ABOVE LIMITATIONS OR EXCLU-
SIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC
LEGAL RIGHTS AND YOU MAY ALSO
HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE OR PROVINCE TO PROV-
INCE.
41658-01 511012002
HUNTER FAN COMPANY _f _I]_'T'j_J } 8
2500 FRISCO AVENUE
MEMPHIS,TN 38114, USA 86
8@2002 HUNTER FAN CO.
This manual suits for next models
2
Table of contents
Other Hunter Humidifier manuals

Hunter
Hunter 35205 User manual

Hunter
Hunter 31011 User manual

Hunter
Hunter 33520 User manual

Hunter
Hunter 37203 User manual

Hunter
Hunter 33200 User manual

Hunter
Hunter The Care Free Humidifier User manual

Hunter
Hunter 35216 User guide

Hunter
Hunter 31004 User manual

Hunter
Hunter 33223 User manual

Hunter
Hunter Care Free Permawick 34407 User manual