Hunter 37203 User manual

43000-01 06/02/2006 © 2006 Hunter Fan Company
www.hunterfan.com
The Care Free®
Warm Mist Humidier
Models 37203, 37204
FRANÇAIS
Consulter la page 15
ENGLISH
See page 1
43000_WM MechHum_06.02.06.indd 6/2/06, 11:15 AM1

43000-01 06/02/2006 © 2006 Hunter Fan Company
2
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing the Care Free®
Warm Mist Humidier by Hunter Fan
Company. Please read and save these
instructions to receive maximum benet
and performance from your humidier.
Important Safety Instructions:
Read all instructions before using
this humidier.
CAUTION: To avoid electrical
shock and/or re, please read all
instructions before use.
1. This humidier may not work properly
on an uneven surface. ALWAYS place
this humidier on a rm, level, and water
resistant surface. ALWAYS place the
humidier at least six (6) inches away from
walls and heat sources, such as stoves,
radiators, or heaters.
2. ALWAYS place the humidier in an area
that is out of the reach of children.
3. Before using the humidier, extend the cord
and inspect for any sign of damage. DO
NOT use the product if the cord has been
damaged.
4. This product has a polarized plug as a safety
feature (one blade is wider than the other).
This plug will t into a polarized outlet only
one way. If the plug does not fully t into
the outlet, reverse the plug. If it still does
not t, contact a qualied electrician. DO
NOT attempt to defeat or override this
feature.
5. ALWAYS unplug and empty the humidier
when it is not in operation or while it is
being cleaned.
6. DO NOT tilt or move the humidier while it
is in operation. Never move the humidier
while there is water in the tank. Empty the
water tank, turn the unit off, and unplug the
unit before moving.
7. In addition to routine maintenance which
may be required, this humidier requires
seasonal cleaning. Refer to and follow the
instructions for CLEANING THE HUMIDIFIER
AND THE WATER TANK.
8. This unit was designed to be used with
distilled and/or tap water. DO NOT
add scented oils, perfumes or fragrance
additives to the water.
9. DO NOT attempt to move or disassemble
the Base while there is hot water still in
the unit. Allow a minimum of fteen (15)
minutes cooling time before moving or
disassembling the Base.
10. ALWAYS use clean, cool tap water to ll
the Water Tank.
11. To avoid the risk of electrical shock, DO
NOT use an extension cord.
12. DO NOT operate outdoors. This humidier
is for indoor use only.
13. DO NOT let water get into the air inlets on
the back of the enclosure, the cord, or the
plug.
14. DO NOT store or use gasoline or other
ammable vapors and liquids near the
humidier.
15. DO NOT touch hot surfaces. DO NOT place
hands or face directly over the Exhaust
Grille while the unit is in operation.
16. DO NOT allow the Exhaust Grille to directly
face a wall surface. Direct mist aimed at a
wall could cause damage, particularly to
wallpaper.
43000_WM MechHum_06.02.06.indd 6/2/06, 11:15 AM2

43000-01 06/02/2006 © 2006 Hunter Fan Company
3
Assembly Of Humidier Parts
The Care Free® Warm Mist Humidier
has a unique, patented design with several
innovative features:
• Removable Boiling Chamber –
The detachable heater can be easily removed
for cleaning and maintenance.
• Humidication System – Water is passed
through a heating element which creates
warm mist to humidify the air. Stagnant water
in the reservoir is eliminated due to minimal
water quantity in the boiler reservoir.
• Built-In Antimicrobial Properties –
The plastic parts in this humidier have
built-in antimicrobial properties to inhibit the
growth of bacteria, mold and fungi that may
affect these parts.
NOTE: The antimicrobial properties built-into
this humidier do not extend to the water,
How The Care Free® Warm Mist Humidier Works
humidied air or users. Conduct routine
cleaning and maintenance based upon use
and individual conditions.
• No White Dust – The Care Free® Warm
Mist Humidier produces no white dust that
can settle on furniture or be inhaled.
NOTE: You may notice mineral deposits
accumulating in the tank base or on other
components. This is normal and comes with
regular usage conditions. If you would like
to remove these deposits and maintain
humidier performance, please see the
section CLEANING THE HUMIDIFIER AND
THE WATER TANK.
• Dishwasher Safe – All components of
The Care Free® Warm Mist Humidier are
top-rack dishwasher safe, except for the
powered base.
Exhaust Grille
Medicine Cup
Water Tank
Adjustable Humidistat
Base
Night Light Button
Power Button
Tank Cap
ENGLISH
43000_WM MechHum_06.02.06.indd 6/2/06, 11:15 AM3

43000-01 06/02/2006 © 2006 Hunter Fan Company
4
1. Remove the Care Free® Warm Mist Humidier
from its packaging.
2. Select a location for your humidier. The
location should be at, hard, water-resistant,
and at least six (6) inches away from walls
and sources of heat. Mount the humidier
on a drip tray if you are using the unit on a
wood surface or other surface which could
be damaged by accidental water spillage or
condensation.
HUNTER WILL NOT ACCEPT RESPONSIBILITY
FOR DAMAGE DUE TO WATER SPILLAGE.
3. Place the Base in the location you selected.
Take the Water Tank to a sink or tub to ll
with water.
4. Unscrew the Tank Cap by twisting it
counterclockwise and ll the Water Tank with
fresh, cool water. NEVER USE HOT WATER.
5. Replace the Tank Cap by screwing it clockwise
onto the Water Tank.
6. Place the Water Tank back onto the Base.
Make sure the Water Tank is properly seated
on the Base or the humidier will not work
properly.
HUNTER WILL NOT ACCEPT RESPONSIBILITY
FOR DAMAGE DUE TO WATER SPILLAGE.
7. Make sure the Power Button is set to OFF and
plug the humidier into the wall outlet.
CAUTION: Never plug in the humidier
while your hands are wet, as electric shock
could occur.
NOTE: Let the humidier sit for one minute after
relling the tank, before turning
the power back ON.
8. Push the Power Button to turn the humidier
ON. Adjust the setting as needed.
Base
Water
Tank
43000_WM MechHum_06.02.06.indd 6/2/06, 11:15 AM4

43000-01 06/02/2006 © 2006 Hunter Fan Company
5
Operating Your Humidier
Push the Power Button on the base of the unit
AGAIN to change the setting to LOW. A yellow
indicator light will be illuminated, which
indicates a LOW setting.
Push the Power Button on the base of the
unit AGAIN to turn the humidier OFF. No
indicator light will be illuminated, which
indicates the unit has been turned OFF.
3. NiteGlo™ Night Light Button*–
Illuminates with a soft blue glow.
Push the NiteGlo™ Button to turn the light
ON or OFF. The night light can be operated
even when the humidier is OFF.
*Not available on all models.
ENGLISH
There are two humidity level controls:
1. Adjustable Humidistat – Allows you to
adjust the humidity setting.
Turn the dial to the right to increase humidity.
Turn the dial to the left to decrease humidity.
NOTE: In a very dry room, the HI setting should
be used to quickly achieve a comfortable level of
humidity. Once the room is at the desired humidity
level, you can turn the Adjustable Humidistat down.
We suggest you begin with a middle setting and
adjust the level using the Adjustable Humidistat to
suit your needs.
2. Power Button – Sets humidity to
HIGH, LOW, or OFF.
Push the Power Button on the base of the
unit ONCE to turn the humidier ON. A green
indicator light will be illuminated, which
indicates a HIGH setting.
NOTE: It may take 2-3 minutes for the humidier to
warm up and begin to release warm mist.
43000_WM MechHum_06.02.06.indd 6/2/06, 11:15 AM5

43000-01 06/02/2006 © 2006 Hunter Fan Company
6
5. Replace the Tank Cap by screwing it clockwise
onto the Water Tank. Make sure that the tank
cap is properly seated before screwing it back
onto the tank to ensure a proper seal.
6. Place the Water Tank back onto the Base.
Make sure the Water Tank is properly seated
on the Base or the humidier will not work
properly.
HUNTER WILL NOT ACCEPT RESPONSIBILITY
FOR DAMAGE DUE TO WATER SPILLAGE.
7. Make sure the Power Button is set to OFF and
plug the humidier into the wall outlet.
CAUTION: Never plug in the humidier
while your hands are wet, as electric shock
could occur.
NOTE: Let the humidier sit for one minute after
relling the tank, before turning the power back
ON.
8. Push the Power Button to turn the humidier
ON. Adjust the setting as needed.
1. When the water level is low, push the POWER
button to turn the humidier OFF and unplug
the humidier.
NOTE: When the tank level is too low, the
humidier will turn OFF and display a red light.
2. Lift the Water Tank and take it to the sink or a
tub to rell.
3. Turn the Water Tank over and unscrew the
Tank Cap by twisting it counterclockwise.
4. Empty the Water Tank and rell it with fresh,
cool water. NEVER USE HOT WATER.
Base
Water
Tank
Relling The Water Tank
Low Water Level
Light (Red)
43000_WM MechHum_06.02.06.indd 6/2/06, 11:15 AM6

43000-01 06/02/2006 © 2006 Hunter Fan Company
7
Reassembly Of Humidier Parts
Exhaust Grille
Medicine Cup
Water Tank
Boiler
Cover
Boiling
Chamber
Adjustable Humidistat
Base
Night Light Button
Power Button
Tank Cap
Many regions have hard water with high
concentrations of minerals. When water evaporates
from the Care Free® Warm Mist Humidier,
minerals may be left behind. These minerals can
form a hard white scale which can be removed
by following the cleaning instructions. The
frequency of cleaning due to mineral build up
varies depending on the quality of water you have.
Failure to perform the necessary cleaning steps can
damage the unit and affect performance.
NOTE: The Water Tank, Tank Cap, Medicine Cup,
Boiler Cover, Boiling Chamber, and Exhaust Grille
are dishwasher safe in the top rack only.
1. Push the POWER button to turn the unit OFF
(the indicator light will be OFF) and unplug
the humidier.
2. Remove the Water Tank and carry it to a sink
or a tub. Unscrew the Tank Cap by twisting it
counterclockwise and empty any water in the
Water Tank.
3. CAUTION: HEATING ELEMENT MAY BE
EXTREMELY HOT.
Allow at least fteen (15) minutes for the hot
water in the Boiling Chamber to cool after
turning the humidier OFF before moving the
Base or removing the Boiling Chamber from
the Base. Pull the Boiling Chamber away from
the Base to remove the Boiling Chamber.
Cleaning The Humidier And The Water Tank
ENGLISH
43000_WM MechHum_06.02.06.indd 6/2/06, 11:15 AM7

43000-01 06/02/2006 © 2006 Hunter Fan Company
8
Boiler
Cover
Boiling
Chamber
Boiler
Base
4. Place the Boiling Chamber into an empty sink
and carefully lift the Boiling Chamber Cover
by pressing the Chamber Cover Release Tab.
This will expose the Heater. Drain all water
and rinse with cool, clean water. Use a soft
brush or sponge to clean the Boiling Chamber
and the Boiling Chamber Cover.
5. Pour one (1) cup of white vinegar into the
Boiling Chamber and allow it to soak for
20-30 minutes. Rinse several times with cool,
clean water. Wipe the Boiler clean if necessary.
6. Before reinstalling the Boiling Chamber, make
sure the three metal pins in the Chamber are
clean and completely dry. Place the Boiling
Chamber Cover into the Boiling Chamber and
slide the Chamber slowly back into place.
Make sure the Chamber ts properly in the
Base.
7. To disinfect the Water Tank, create a solution
of one (1) cup of white vinegar and one (1)
gallon of clean water. Fill the Water Tank
with the solution and allow it to soak for 20
minutes, occasionally swishing the solution to
wet all interior surfaces. Empty the Water Tank
completely and rinse with clean water several
times. Rell the Water Tank with cool, clean
water and place it back on the humidier
Base.
8. NEVER use any metal or hard object, which
could cause scratching of the humidier
surface, to clean plastic parts. NEVER use
gasoline, kerosene, glass cleaner, furniture
polish, paint thinner, or other household
solvents to clean any part of the humidier.
9. The Water Tank should be drained EACH DAY,
rinsed, and relled with clean tap water.
10. To clean the exterior surfaces, use a solution
of water and mild detergent with a damp
cloth. Rinse the surfaces with clean water and
dry with a cloth. Allow sufcient time to dry
before plugging the electrical cord back into
the outlet.
11. Place the Water Tank back onto the Base and
resume normal use.
Base
Water
Tank
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM8

43000-01 06/02/2006 © 2006 Hunter Fan Company
9
If you do not plan to use your humidier for
an extended period of time, such as during the
summer months, it is important that you follow
these instructions to help prevent problems from
developing in the unit.
1. Clean your humidier as outlined in the
CLEANING THE HUMIDIFIER AND THE
WATER TANK section.
Storage Tips
2. Make sure all water is emptied from
the tank and the hot and cold water
reservoirs.
3. Make sure the unit is completely dry.
4. Leave the Tank Cap off to expose the
Water Tank to air.
5. Pack the humidier in the original
carton and store it in a cool, dry place.
• Problem: Humidier
not misting.
Solution:
1. Make sure the unit is plugged in.
2. Check the circuit breaker or fuses.
3. Adjust the humidity level using the Power
Button and the Adjustable Humidistat.
Once the room reaches the set humidity
level, the humidier will turn OFF; this is
normal.
4. Remove and rell the Water Tank.
5. Reposition the Water Tank on the Base.
• Problem: Humidity output and
water usage decreased.
Solution:
1. Check the Adjustable Humidistat and
Power Button to make sure they are set
to the desired humidity level.
2. Clean any components that have
mineral build-up. Refer to the section on
CLEANING THE HUMIDIFIER AND THE
WATER TANK.
Troubleshooting
If you have questions or problems, please call 1-888-830-1326 for assistance before returning
the unit to the retailer.
ENGLISH
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM9

43000-01 06/02/2006 © 2006 Hunter Fan Company
10
Service Parts
To obtain a service part for your humidier, call Hunter Customer Service at 1-888-830-1326 or e-mail
us at T[email protected]. Please be prepared to tell the operator the model number of your
humidier, the name of the part you need to replace, and the part number.
Model
Number Boiler Cover Exhaust Grille Medicine Cup Tank Cap Water Tank
37203 96362-01-325 86731-01-325 75690-01-325 83736-01-325 96361-01-326
37204
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM10

43000-01 06/02/2006 © 2006 Hunter Fan Company
11
Hunter Fan Company, Inc. makes the following warranty to the original residential user or
consumer purchaser of the Care Free® Warm Mist Humidier.
If any part of the Care Free® Warm Mist Humidier ("Humidier") fails during the
rst three (3) years from the date of installation due to a defect in material or workmanship,
we will provide a replacement part free of charge. If no replacement part can be provided,
we will replace your humidier.
If your humidier fails anytime within one (1) year after the date of installation due to a defect in
material or workmanship, labor to repair the defect will be provided free of charge at our nearest
service center or at our Service Department in Memphis, Tennessee. You will be responsible for all
parts and labor costs after this one year period.
If your humidier water tank, boiler cover, boiling chamber, base, knobs or tank cap fail at any
time within one (1) year after the date of sale to you due to a defect in material or workmanship,
we will repair, or at our option, replace the water tank, boiler cover, boiling chamber, base,
knobs or tank cap free of charge for parts or labor at our nearest service center or at our Service
Department in Memphis, Tennessee.
IF THE ORIGINAL RESIDENTIAL USER OF CONSUMER PURCHASER CEASES TO OWN THE
HUMIDIFIER, THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT,
INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE VOIDED.
NO WARRANTY, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RESPECT TO THE FILTER.
THE WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF
ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO THE MOTOR IS
EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE.
This warranty is voided if your humidier is not purchased and used in the USA or Canada.
This warranty excludes and does not cover defects, malfunctions or failures which were caused
by repairs by persons not authorized by Hunter Fan Company, or accessories not authorized
by Hunter Fan Company, mishandling, modications, or damage to the humidier while in
your possession, or unreasonable use, including failure to provide reasonable and necessary
maintenance. This warranty does not cover humidiers used in commercial applications. There are
no express or implied warranties as to commercial purchasers or users.
Hunter Fan Company
The Care Free® Warm Mist Humidier
3 Year Limited Warranty
ENGLISH
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM11

43000-01 06/02/2006 © 2006 Hunter Fan Company
12
To obtain service, contact the nearest Hunter authorized service center or the Hunter Fan
Company Service Department at 2500 Frisco Avenue, Memphis, Tennessee, 38114 or at
(901) 248-2222. You will be responsible for insurance and freight or other transportation to
our factory service center. We will return the humidier, freight prepaid, to you. The humidier
should be properly packaged to avoid damage in transit since we will not be responsible for any
such damage. Proof of purchase is required when requesting warranty service. The purchaser
must present the sales receipt or other documentation that establishes proof of purchase.
IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT, INDIRECT, SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE
HUMIDIFIER. YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE.
SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW:
• LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS
• THE EXCLUSION OR LIMITATION OF DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES
• THE EXCLUSION OR INVALIDITY OF EXPRESS OR IMPLIED WARRANTIES IF THE USER
CEASES TO OWN THE HUMIDIFIER
• THE LIMITATION OF REMEDIES AND RECOURSES AVAILABLE TO THE PURCHASER, OR
• THE INVALIDITY OF AN EXPRESS WARRANTY WHEN A PRODUCT IS IDENTIFIED BY
BRAND NAME IS NOT USED (UNLESS SPECIFIC CONDITIONS ARE FULFILLED)
SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE.
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM12

43000-01 06/02/2006 © 2006 Hunter Fan Company
13
Other Home Comfort Products from Hunter
Hunter Original®QuietFlo™ HEPA
Air Purier
Programmable
Thermostat
To learn more about Hunter Fan products, visit our web page at:
www.hunterfan.com
HUNTER FAN COMPANY
2500 FRISCO AVENUE
MEMPHIS, TN 38114, USA
ENGLISH
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM13

43000-01 06/02/2006 © 2006 Hunter Fan Company
14
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM14

43000-05 06/02/2006 © 2006 Hunter Fan Company
15
FRANÇAIS
Consulter la page 15
ENGLISH
See page 1
www.hunterfan.com
Humidicateur
à buée chaude
Care Free®
Modèles 37203, 37204
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM15

43000-05 06/02/2006 © 2006 Hunter Fan Company
16
LIRE ET CONSERVER CES CONSIGNES
Merci de votre achat de l’humidicateur à
buée chaude Care Free® de la société Hunter
Fan Company. Veuillez lire et conserver ces
consignes que vous puissiez bénécier des
avantages et de la performance de votre
humidicateur.
Importantes consignes de sécurité :
Lire toutes les consignes avant de
vous servir de cet humidicateur.
ATTENTION : Pour prévenir un choc
électrique et/ou un incendie, veuillez
lire toutes les consignes avant usage.
1. Cet humidicateur pourrait ne pas
fonctionner correctement sur une
surface inégale. TOUJOURS poser cet
humidicateur sur une surface solide,
horizontale et résistante à l’humidité.
TOUJOURS poser l’humidicateur à au
moins 15 cm ( 6 po) des murs et des sources
de chaleur comme les poêles, les radiateurs
et les réchauds.
2. TOUJOURS poser l’humidicateur dans une
aire hors de la portée des enfants.
3. Avant de se servir de l’humidicateur,
inspecter le cordon pour vérier s’il est
endommagé. NE PAS utiliser produit si le
cordon a été endommagé.
4. Ce produit dispose d’une che polarisée
pour sa sécurité (une broche est plus
large que les autres). Cette che ne peut
être insérée dans une prise polarisée
que d’une seule manière. Si la che ne
s’insère pas complètement dans la prise,
retournez-la. Si elle ne s’insère toujours pas,
contacter un électricien qualié. NE PAS
essayer d’annuler ou de contourner cette
caractéristique.
5. TOUJOURS débrancher et vider
l’humidicateur quand vous ne l’utilisez pas
ou que vous le nettoyez.
6. NE PAS incliner ou déplacer
l’humidicateur quand il fonctionne. Ne
jamais déplacer l’humidicateur quand il y
de l’eau dans le réservoir. Vider le réservoir
d’eau, éteindre l’appareil et le débrancher
avant de le déplacer.
7. En plus de l’entretien de routine nécessaire,
cet humidicateur requiert un nettoyage
saisonnier. Voir et suivre les consignes de
NETTOYAGE DE L’HUMIDIFICATEUR ET DU
RÉSERVOIR D’EAU.
8. Cet appareil à été conçu pour utiliser de
l’eau distillée et ou de l’eau du robinet. NE
PAS ajouter d’huiles parfumées, de parfums
ou d’additifs parfumés à l’eau.
9. NE PAS essayer de déplacer ou de
désassembler la base quand il y a encore
de l’eau chaude dans l’appareil. Laisser
refroidir au moins quinze (15) minutes avant
de déplacer ou de désassembler la base.
10. TOUJOURS utiliser de l’eau du robinet
propre et froide pour remplir le réservoir.
11. Pour prévenir le risque d’un choc électrique,
NE PAS utiliser de cordon prolongateur.
12. NE PAS faire fonctionner à l’extérieur. Cet
humidicateur est uniquement pour usage
intérieur.
13. NE PAS laisser de l’eau s’introduire dans
les prises d’air à l’arrière du boîtier, ou sur le
cordon et la che.
14. NE PAS entreposer ou utiliser d’essence
ou autres vapeurs et liquides inammables
près de l’humidicateur.
15. NE PAS toucher les surfaces chaudes.
NE PAS placer les mains ou le visage
directement au-dessus de la grille
d’évacuation quand l’appareil fonctionne.
16. NE PAS laisser la grille d’évacuation faire
face à un mur. La buée dirigée vers un mur
peut causer des dommages, en particulier
au papier peint.
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM16

43000-05 06/02/2006 © 2006 Hunter Fan Company
17
FRANÇAIS
Assemblage des pièces de l’humidicateur
L’humidicateur à buée chaude Care Free®
dispose d’une conception brevetée unique,
dotée de plusieurs caractéristiques novatrices :
• Chambre ébullition amovible –
Le réchaud détachable peut être facilement
enlever pour le nettoyage et l’entretien.
• Système d’humidication – L’eau passe
par un élément chauffant qui crée une buée
chaude pour humidier l’ air. L’eau stagnante
du réservoir est éliminée à cause de la quan-
tité minimale d’eau dans le réservoir de la
chaudière.
• Propriétés antimicrobiennes inté-
grées – Les pièces en plastique de cet humi-
dicateur ont des propriétés antimicrobiennes
intégrées pour empêcher la croissance de
bactéries, de moisissures et de champignons
qui peuvent se développer sur ces pièces.
NOTE : Les propriétés antimicrobiennes
intégrées à cet humidicateur ne s’étendent
Comment fonctionne
l’humidicateur à buée chaude Care Free®
pas à l’eau, à l’air humidié ou aux usagers.
Faire un nettoyage et un entretien de routine
selon l’usage et les conditions personnelles.
• Pas de poussière blanche – L’humidi-
cateur à buée chaude Care Free® ne produit
aucune poussière blanche qui ferait des
dépôts sur le meuble ou qui pourrait être
inhalée.
NOTE : Vous pourriez constater le dépôt
de minéraux à la base du réservoir ou sur
d’autres éléments. Cela se produit dans des
conditions d’usage normal. ‘Si vous désirez
enlever ces dépôts et maintenir l’efcacité
de l’humidicateur, veuillez voir le chapitre
NETTOYAGE DE L’HUMIDIFICATEUR ET DU
RÉSERVOIR D’EAU.
• Résistant au lave-vaisselle – Tous les
éléments de l’humidicateur à buée chaude
Care Free® sont résistants au lave-vaisselle
dans le panier supérieur sauf la base motori-
sée.
Grille d’évacuation
Godet pour
médicament
Réservoir d’eau
Bouchon du réservoir
Base
Humidistat réglable
Bouton de veilleuse
Bouton de mise
en marche
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM17

43000-05 06/02/2006 © 2006 Hunter Fan Company
18
1. Retirer l’humidicateur à buée chaude Care
Free® de son emballage.
2. Choisir un emplacement pour votre humidi-
cateur. L’emplacement devra être plan, dur,
résistant à l’eau et à au moins quinze (15)
centimètres (6 po) des murs et des sources de
chaleur. Poser l’humidicateur sur un ramasse-
gouttes si vous voulez utiliser l’appareil sur
une surface de bois ou tout autre surface
qui serait endommagée par un déversement
accidentel d’eau ou la condensation.
HUNTER N’ACCEPTERA AUCUNE RESPONSA-
BILITÉ POUR DES DOMMAGES DUS À DES
DÉVERSEMENTS D’EAU.
3. Placer la base à l’endroit choisi. Remplir le
réservoir d’eau dans un évier ou un bain.
4. Retirer le bouchon du réservoir en le dévissant
dans le sens antihoraire et remplir le réservoir
d’eau propre et fraîche. NE JAMAIS UTILI-
SER D’EAU CHAUDE.
5. Replacer le bouchon en le vissant dans le sens
horaire sur le réservoir.
6. Replacer le réservoir d’eau sur la base. Assu-
rez-vous que le réservoir est bien xé sur la
base ou l’humidicateur ne fonctionnera pas
correctement.
HUNTER N’ACCEPTERA AUCUNE RESPONSA-
BILITÉ POUR DES DOMMAGES DUS À DES
DÉVERSEMENTS D’EAU.
7. Vérier que bouton de mise en marche est à
OFF (arrêt) et brancher l’humidicateur dans
la prise murale.
ATTENTION : Ne jamais brancher l’humidi-
cateur avec des mains humides car cela
pourrait causer un choc électrique.
NOTE : Laisser l’humidicateur reposer pendant
une minute après avoir rempli le réservoir, avant de
le mettre en marche.
8. Mettre l’humidicateur à ON en appuyant
sur le bouton de mise en marche. Ajuster le
réglage comme désiré.
Réservoir
d’eau
Base
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM18

43000-05 06/02/2006 © 2006 Hunter Fan Company
19
FRANÇAIS
Utilisation de votre humidicateur
Il existe deux commandes de niveau d’humidité :
1. Humidistat réglable – Vous permet
d’ajuster le réglage de l’humidité.
Tourner le cadran vers la droite pour augmen-
ter l’humidité.
Tourner le cadran vers la gauche pour dimi-
nuer l’humidité.
NOTE : Dans une pièce très sèche, le réglage HI
(élevé) devra être utilisé pour atteindre rapidement
un niveau confortable d’humidité. Une fois la
pièce à son niveau désiré d’humidité, vous pouvez
réduire le réglage de l’humidistat. Nous suggérons
que vous commenciez par un réglage moyen et
que vous ajustiez ensuite le niveau à l’aide de
l’humidistat réglable selon vos besoins.
2. Bouton de mise en marche – Règle l’hu-
midité sur HIGH (élevé), LOW (bas), ou OFF
(arrêt).
Mettre l’humidicateur à ON en appuyant
sur le bouton de mise en marche à la base de
l’appareil. Un voyant lumineux vert s’allumera
qui indique un réglage élevé (HIGH).
NOTE : L’humidicateur pourrait mettre 2 à 3
minutes à se réchauffer et à émettre de la buée
chaude.
Appuyer À NOUVEAU sur le bouton de
mise en marche à la base de l’appareil pour
changer le réglage à LOW (bas). Un voyant
lumineux jaune s’allumera qui indique un
réglage bas (LOW).
Mettre l’humidicateur à OFF en appuyant
sur le bouton de mise en marche à la base
de l’appareil. Aucun voyant lumineux ne
s’allumera, indiquant que l’appareil a été
arrêté (OFF).
3. Bouton de veilleuse* NiteGlo™ –
Éclaire avec une douce lueur bleue.
Appuyer sur le bouton NiteGlo™ pour allumer
ou éteindre la veilleuse. La veilleuse peut
fonctionner même lorsque l’humidicateur est
à l’arrêt.
*N’équipe pas tous les modèles.
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM19

43000-05 06/02/2006 © 2006 Hunter Fan Company
20
du réservoir est bien posé avant de le revisser
pour être sûr de bien le fermer.
6. Replacer le réservoir d’eau sur la base. Assu-
rez-vous que le réservoir est bien xé sur la
base ou l’humidicateur ne fonctionnera pas
correctement.
HUNTER N’ ACCEPTERA AUCUNE RESPONSA-
BILITY POUR DES DOMMAGES DUS À DES
DÉVERSEMENTS D’EAU.
7. Vérier que bouton de mise en marche est à
OFF (arrêt) et brancher l’humidicateur dans
la prise murale.
ATTENTION : Ne jamais brancher l’humidi-
cateur avec des mains humides car cela
pourrait causer un choc électrique.
NOTE : Laisser l’humidicateur reposer pendant
une minute après avoir rempli le réservoir, avant de
la remettre en marche.
8. Mettre l’humidicateur à ON en appuyant
sur le bouton de mise en marche. Ajuster le
réglage comme désiré.
1. Quand le niveau de l’eau est bas, arrêter
l’humidicateur en appuyant sur le bouton de
mise en marche et le débrancher.
NOTE: Si le niveau de l’eau est trop bas, l’humidi-
cateur s’arrêtera et un voyant rouge s’allumera.
2. Soulever le réservoir et aller à l’évier ou au
bain pour le remplir à nouveau
3. Retourner le réservoir d’eau et dévisser son
bouchon dans le sens antihoraire.
4. Vider le réservoir et le remplir à nouveau
d’eau propre et froide. NE JAMAIS UTILISER
D’EAU CHAUDE.
5. Replacer le bouchon en le vissant dans le sens
horaire sur le réservoir. Vérier que le bouchon
Remplir à nouveau le réservoir d’eau
Voyant lumineux de niveau
bas en eau (Rouge)
Base
Réservoir
d’eau
43000_WM MechHum_06.02.06.indd 6/2/06, 11:16 AM20
This manual suits for next models
3
Table of contents
Languages:
Other Hunter Humidifier manuals

Hunter
Hunter 34200 User manual

Hunter
Hunter 33200 User manual

Hunter
Hunter 32305 User manual

Hunter
Hunter NiteGlo Humidifier Plus Evaporative... User manual

Hunter
Hunter 31011 User manual

Hunter
Hunter 35218 User manual

Hunter
Hunter 34357 User manual

Hunter
Hunter 33223 User manual

Hunter
Hunter 33520 User manual

Hunter
Hunter 31206 User guide

Hunter
Hunter 33283 User manual

Hunter
Hunter 38200 User manual

Hunter
Hunter 32505 User manual

Hunter
Hunter QLS-03CB User manual

Hunter
Hunter The Care Free Humidifier User manual

Hunter
Hunter 37205 User manual

Hunter
Hunter 36202 User manual

Hunter
Hunter 33116 User guide

Hunter
Hunter 35202 User manual

Hunter
Hunter 34257 User manual