Dual Circuit Cords on the same circuit Move one cord to outlet on different circuit
Indicator No voltage from one/ both outlets Check circuit breakers – Reset breakers or move cords
Not Lighted Light Bad Replace Light
Dual Circuit Indicator Bad Replace indicator
One/Both Outlets Wired wrong
If hot & neutral sides switched on outlet, machine will work,
but light will not turn ON.
Pump-out Building circuit breaker tripped. Reset breakers or move cords to other outlets
not working Faulty power cord
Replace cord (1696-6412)
Faulty switches or internal wiring
Check wiring & test switches - Repair as needed *
(NM5714)
Pump-out pump faulty Replace pump-out pump (AP37)
Pump-out filter clogged
Clean pump-out filter - Keep recovery tank clean –
Use Hydro-Filter AC10
Discharge hose restricted Un-kink, clean out or replace hose
Pump-out pump clogged Remove and clean out pump
Vacuum Building circuit breaker tripped. Reset breakers or move cords to other outlets
Motor Faulty power cord
Replace cord (1696-6412)
not running Faulty switches or internal wiring Check wiring & test switches - Repair as needed *
Vacuum motor faulty Replace vacuum motor (AV010)
Loss of Vacuum motor faulty Replace vacuum motor (AV010)
Vacuum Vacuum motor gasket damaged Replace gasket (PA010A)
Recovery tank lid gasket damaged
Replace lid or gasket (1650-5695 or 1663-5397)
Drain valve open Close valve
Drain valve leaking Repair or replace drain valve (PEA11)
Vacuum motor hoses loose /
leaking Reconnect or replace vacuum motor hoses
Vacuum Valve in wrong Position Check Vacuum Gate Valve Position. – PAGE 8
Vacuums not connected properly See vacuum connection instructions – PAGE 8
Vacuum hose or tool clogged Clean out vacuum hoses and tool
Vacuum hoses or cuffs leaking Replace vacuum hoses, cuffs & connectors as needed
Recovery tank full Drain tank
Float shutoff filter clogged Clean float shutoff filter
Float stuck in float shutoff Repair or replace float shutoff
Pump-out Pump faulty Repair or replace pump out pump (AP37)
Recovery tank damaged Replace recovery tank
Chemical not Solution tank not filling Check & repair auto fill assembly
feeding Chemical hose restricted Un-kink, shorten, clean out or replace hose
Filter screen plugged Clean or replace filter (PDE100-11P)
Low Incoming Water Pressure
Move bottle & shorten chemical hose to improve draw –
Find other water source.
Wrong size metering tip Change metering tip
Chemical proportioner faulty Replace chemical proportioner (PDE61-22-3)
Check valve in filter faulty Replace filter (PDE100-11P)
*
: To reduce the risk of fire electrical shock or injury repairs to wiring should only be
performed by experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service
center to perform tests and repairs to wiring and switches.