Hydrofarm PAR Source Phantom DE1000Lh User manual

Thank you for purchasing the Phantom DE Double-Ended 1000W Open Reflector. When
used with a Phantom DE ballast and double-ended 1000W HPS lamp, this reflector is
engineered to provide the widest, most even light spread over the growing area.
WARNING! FAILURE TO FOLLOW OUR GUIDELINES COULD RESULT IN ELECTRICAL
SHOCK. DO NOT TOUCH, MOVE, SPRAY, OR CLEAN YOUR LIGHT FIXTURE WHEN IT
IS PLUGGED IN. ALLOW IT TO COOL DOWN BEFORE HANDLING. RECOMMENDED
MOUNTING CLEARANCE FOR YOUR FIXTURE IS 8"-12" ON ALL SIDES. DO NOT
MOUNT DIRECTLY TO ANY SURFACE. MAKE SURE TO DISCONNECT THE POWER
WHEN CHANGING THE LAMP.
DOUBLE-ENDED REFLECTOR
INSTRUCTION MANUAL
DE1000Lh
A division of

2 hydrofarm.comparsource.com
ASSEMBLING THE REFLECTOR
1. Upon opening the box, note any dented, deformed, or damaged parts. If any part of your unit is broken or
damaged, immediately notify your retailer or distributor.
2. Remove reflector from plastic bag and inspect for any damages. Handle reflector carefully to avoid deforming
the reflector, which can effect the output efficiency.
3. Remove hardware from plastic bag and ensure you have all parts as shown in PHOTO A.
NOTE: Hardware bag may be inside cardboard end piece.
4. For "Remote" configuration use:
4a. Install the two eyebolts into the tapped holes on top of the reflector as shown in PHOTO B.
4b. Install lamp into reflector connectors as shown in lamp instructions.
4c. Connect your ballast to the reflector using CSXCORD (sold separately) in PHOTO C.
5. For "Attached" configuration use (applies to Phantom Commercial DE Ballast only):
5a. Install only one eyebolt into the tapped hole in the top of the reflector located opposite (furthest from) the
input lamp connector as shown in PHOTO D. Install a second eyebolt into the ballast hanging bracket as
shown below in PHOTO E.
5b. Attach the reflector assembly to the rear of the Phantom ballast by inserting the pin on the reflector
bracket into the circular slot in the ballast chassis as shown in PHOTO F and sliding the reflector assembly
downward until the two large tabs at the bottom enter the slots in the ballast’s end cap as shown in
PHOTO G and the sheet metal clip securely grips the ballast’s end cap as shown in PHOTO H.
5c. Attach the ballast bracket to the other end cap of the ballast by inserting the bracket's two folded tabs
into the corresponding slots on the end cap as shown in PHOTO I. Be sure that the bracket’s inset clip (just
beneath the eyebolt) snaps securely onto the top of the end cap. When attached securely to the ballast,
the ballast bracket should appear as it does in photo J.
5d. Plug reflector into ballast and as shown in photo K.
Photo A Photo C
Photo B
Photo GPhoto FPhoto EPhoto D
Photo KPhoto JPhoto H Photo I

3
hydrofarm.com A division of
LAMP INSTALLATION
Open both lamp holders by sliding them outwards and away from the center of the fixture, as shown in PHOTO A.
Do not apply excessive force when installing lamp.
The bulb must be oriented so that the high voltage wire end/lead (the end near the getter, which is the small
square tab attached to the wire loop) is installed in the socket end closest to the ballast.
Also be sure that the bulb is oriented so that the burner filament (the long wire that runs along the full length of
the arc tube) is positioned upward, facing the top inside surface of the reflector.
Ensure that the wire ends/leads are not bent or frayed, as this will prevent proper installation. Begin by installing
the double-ended lamp within the lamp holders shown in PHOTOS B & C.
The wire ends/leads must be fully seated as shown (PHOTOS D & E) before sliding each socket end closed.
After sliding the socket ends closed, be certain that there is no gap between the edge of the sliding section and
the part it meets at the end of the slide path. Once lamp is positioned correctly, slide the lamp holder inward
toward the center of the bulb to secure and lock the lamp in place as shown in PHOTOS F & G.
Please note: Do not force the lamp holders closed.
This could cause damage to both the lamp and lamp holders.
Do not handle lamp with bare hands. Always wear surgical or cloth gloves when handling lamp to minimize
fingerprints and oils left on the lamp. If the lamp needs cleaning after installation, use a soft dry cotton cloth
to wipe off fingerprints or oils.
Photo B
Photo A Photo C
Photo F Photo G
Photo D Photo E

4 hydrofarm.comparsource.com
HANGING YOUR FIXTURE
1. Make sure your unit is unplugged.
2. Hang the fixture from a strong cord or chain from both ends. Make sure you have hooks solidly screwed into
the studs in the ceiling. If you cannot locate the studs, insert expansion anchors into the ceiling. The hooks
should be rated to hold at least 50 lbs each.
TIPS
• The lamp may require 10-30 minutes cooling time before restarting.
• After you plug the reflector in, the bulb may require several minutes to reach its full brightness. In the event of
a momentary power interruption, the bulb will not restart immediately.
• Some variation in the color of light emitted by the bulb is not unusual, especially in the first 100 hours of
operation.
• Never pull the cord to unplug the reflector, pull the plug only.
• Avoid scratching the bulb, subjecting it to undue pressure, or getting it wet when it is hot; these actions may
cause the bulb to break.
• In the event of bulb breakage, immediately unplug the reflector to prevent exposure to ultraviolet energy,
which may be harmful to eyes and skin.
• Keep room temperature below 950F, with adequate air circulation by fan in the growing area.
• The DE lamp produces very high-intensity light and was originally designed for commercial
growing operations. Please take care to consider proximity to plants when installing your fixture. You may want
to allow more vertical space between the plant canopy and the fixture to mitigate the high-intensity light and
heat in the plant area.
• Always use a heavy-duty 3-pronged grounded timer, rated for at least 15 amps. Many 7-day digital timers are
not rate for 1000W lamps.
• Unplug ballast when changing or removing the lamp. Failure to do so can cause ballast failure or improper
diagnosis.
LIMITED WARRANTY
Hydrofarm warrants this reflector to be free from defects in materials and workmanship. The warranty term is
1-year beginning on the date of purchase. Misuse, abuse, or failure to follow instructions is not covered under
this warranty, nor is damage caused by failure to properly install the lamp according to these instructions. This
warranty also does not cover any labor associated with installation or removal of the reflector. Hydrofarm will,
at our discretion, repair or replace the reflector covered under this warranty if it is returned to the original place
of purchase. To request warranty service, please return the reflector, with original sales receipt and packaging,
to your place of purchase. The purchase date is based on your original sales receipt. For more detailed warranty
information, visit our website.
SPECIFICATIONS
Relamp with 1000 watts
Type K12x30s
400V HPS lamp
PARTS LIST
1- Phantom DE Open Reflector
1- Hanging hardware kit
1- Instructions

5
hydrofarm.com A division of
Nous vous remercions d’avoir acheté le réflecteur ouvert de 1 000 W à double culot
Phantom DE. Utilisé avec un ballast Phantom DE et une lampe HPS de 1 000 W à double
culot, ce réflecteur est conçu pour diffuser une lumière extrêmement large et régulière sur
la zone de culture.
AVERTISSEMENT ! LA NON OBSERVATION DE NOS INSTRUCTIONS PEUT
ENTRAÎNER UN RISQUE D'ÉLECTROCUTION. NE PAS TOUCHER, DÉPLACER,
VAPORISER OU NETTOYER VOTRE DISPOSITIF D’ÉCLAIRAGE LORSQU’IL EST
BRANCHÉ. LE LAISSER REFROIDIR AVANT TOUTE MANIPULATION. LE JEU DE
MONTAGE RECOMMANDÉ POUR VOTRE DISPOSITIF EST DE 8" À 12" DE CHAQUE
CÔTÉ. NE PAS LE POSER DIRECTEMENT SUR UNE SURFACE. TOUJOURS DÉBRANCHER
L’ALIMENTATION AVANT DE REMPLACER LA LAMPE.
RÉFLECTEUR À DOUBLE CULOT
MANUEL D’UTILISATION
DE1000Lh
Table of contents
Languages: