Hygenic Parabath User manual

Parabath®
Paraffin Heat Therapy
oWner’sguide
ATTENTION: READ ALL INSTRUCTIONS BEFORE USING
Keep manual in safe location for future reference.

PARABATH®
1
ATTENTION: READ OWNER’S GUIDE
BEFORE OPERATING UNIT
Table of ConTenTs
Important Safety Information to be Read Before Using ............... 2
Warnings........................................................................................ 3
Instructions for Use........................................................................ 4
Treatment Steps for the Parabath Unit........................................... 5
Cleaning and Refilling................................................................... 6
Troubleshooting Guide .................................................................. 7
Parabath Unit and Accessories....................................................... 8
Warranty ........................................................................................ 9
Notes ............................................................................................ 10

PARABATH®
2
imporTanT safeTy informaTion
To be read before using
INDICATIONS
The Parabath Unit is used to relieve pain associated with arthritis and
chronic joint inflammation for the hands, feet and elbows. It may also be
used to soften dry, cracked skin.
CONTRA-INDICATIONS
Do not use the Parabath Unit:
1. When open cuts or broken skin are present.
2. In the presence of inflamed or irritated skin conditions.
3. When peripheral vascular disease or impaired circulation are present.
4. If sensation of the hand or foot is reduced or absent.
PARTS OF PARABATH UNIT
Flat, broad heating elements and
precise thermostats - UL listed
Deep, even heating,
easy-to-clean stainless
steel tank
Paraffin
Tough insulated
ABS housing
Convenient, recessed
carrying handles

Warnings
READ ALL INSTRUCTIONS BEFORE USING. KEEP AWAY FROM
WATER. KEEP AWAY FROM CHILDREN.
DANGER: EXPLOSIVE HAZARD. EQUIPMENT NOT SUITABLE FOR
USE IN THE PRESENCE OF A FLAMMABLE ANESTHETIC MIXTURE
WITH AIR OR WITH OXYGEN OR NITROUS OXIDE.
Do not operate this unit when tank is empty or contains substance other than
Parabath Paraffin. Failure to keep sufficient paraffin in tank may result in
temperature variation and premature failure of the unit.
After Parabath Unit is plugged in, wait at least 5 hours before initial use. Higher
melt temperatures exist during initial heat cycle, which could result in skin irritation
or burns.
Do not use while bathing. Place and store Parabath Unit in a level secure location to
prevent unit from falling or being pulled into a filled tub or sink. Do not submerge
unit in water or other liquid. If unit falls into water, unplug immediately; do not
reach into the water.
WARNING: To reduce the risk of burns, electrocution, fire or injury to
persons:
Use this appliance only for its intended use as described in the Parabath Owner’s
Manual. The use of attachments, not recommended by the manufacturer, may cause
hazards.
Use unit only with a verified 3-prong outlet that has been grounded to reduce risk of
electric shock.
Do not leave appliance unattended while operating or plugged in. Always unplug
the Parabath Unit immediately after final use and allow to cool thoroughly prior to
handling, cleaning, or storing.
Never operate unit if the cord or plug are damaged, is not working properly, has
been dropped in water or damaged in any manner. Keep the cord away from hot or
heated surfaces.
Parabath Unit is designed to be used with Parabath Paraffin. Using other paraffin
could result in potential injury.
CAUTION:
Test temperature of paraffin prior to use on a small area of hand to assure paraffin is
at usable temperature (126°-134°F / 52°-57°C).
A physician should be consulted prior to use if client has any of the following
conditions: sensitive skin, susceptible to allergic reactions, has circulatory problems
or other potentially complicating risk factors.
Do not overfill unit or operate unit with paraffin below the fill line shown on tank.
When adding paraffin, take caution to avoid splashing.
PARABATH®
3

PARABATH®
4
insTruCTions for use
INITIAL PREPARATION
Unpack the Parabath Unit and place it on a sturdy, level surface.
Remove the packaging materials from the Parabath Universal
Paraffin, then stack all 6 bars inside the tank maximizing contact
with the bottom of the tank.
Plug in the electrical cord. The amber power light on the unit
indicates the unit is operating. Do not use the unit for at least 5
hours after it is first plugged in.
Place the lid on the unit to cover the melting tank and wait a
minimum of 5 hours before using. The usable operating temperature
is from 126°-134°F/52°-57°C.
Parabath
Universal Paraffin can be used with the
Parabath Unit and other paraffin units.

PARABATH®
5
TreaTmenT sTeps
1. Using an anti-bacterial soap, wash the area to be treated and then dry
thoroughly.
2. Test the temperature of the melted paraffin by thermometer (126°-
134°F/52°-57°C), or test a small portion of the skin to make sure the
paraffin is not too hot for usage.
3. Briefly dip a small portion of the hand, foot or elbow into the paraffin
and immediately remove. Continue dipping the entire hand, foot or
elbow to completely coat with warm paraffin, then remove
immediately. Repeat the dipping procedure 5-10 times to assure a
complete coating of paraffin. The coated hand, foot or elbow may now
be removed, or kept submerged for a longer period of heat therapy.
Note: If preferred, paraffin coating may be accomplished by dipping a
soft brush in the paraffin and applying consecutive brush strokes to the
desired area.
4. As an option after final paraffin coating, place the coated hand, foot or
elbow in a Parabath liner or plastic bag and cover with Parabath Mitt
or Bootie, or wrap it with a towel to retain heat for up to 30 minutes.
If the heat becomes too intense, remove the towel and strip off the
paraffin immediately.
5. At the conclusion of treatment, remove towel and plastic bag (if
used), then strip off the paraffin. Due to the tendency of the wax to
accumulate residue from the hands, it is recommended that the used
wax be discarded.
6. Place the lid back on the unit, and leave the unit plugged in, ready for
the next use.
7. Add additional paraffin to the tank when the level of paraffin falls
below the fill line shown on the tank (approximately 3 inches from the
bottom of the tank). The unit should be filled with paraffin to a point
midway between the fill lines shown on the inside of the metal tank.

PARABATH®
6
Cleaning and refilling
The Parabath Unit should be cleaned when significant discoloration or
yellowing of the paraffin is noticed or when excessive sediment is ob-
served in the tank. Do not attempt to clean and refill the unit while it is
still plugged in.
PROCEDURE TO EMPTY AND CLEAN THE TANK
1. Unplug the unit.
2. Empty the paraffin tank by the following method:
While in liquid form, lay the cover crosswise on the tank and place a
length of rope with knots on each end into the paraffin (Fig. 1), draping
over the cover.
Allow the paraffin to cool and solidify, requiring approximately 24 hours.
Plug the unit in just long enough for the paraffin to loosen in the tank.
Unplug the unit and pull out the rope with paraffin attached in
block form (Fig. 2).
3. Clean the tank.
Do not use water to clean the unit. Never expose unit to water or
submerge unit in water.
Use paper towels and a mild, non-abrasive, non-chlorine based
household cleanser to remove remaining paraffin residue.
4. Refill the tank with Parabath Universal Paraffin Refills
following initial use instructions.
NOTE: Use of an abrasive
or chlorine-based cleanser
could damage the
stainless steel surface
of the tank.
Figure 1 Figure 2

PARABATH®
7
IF YOU NOTICE
Paraffin hardening in
the tank.
Paraffin has discolored.
Sediment in the tank.
Less than 3 inches of
paraffin in the tank.
Operating light is out.
Paraffin takes longer than
normal to melt.
THE LIKELY CAUSE
Frequent use has depleted
the oil component of the
paraffin.
Paraffin in use has a
higher melting
temperature than
Parabath Paraffin.
Thermostat is not
functioning correctly.
Normal use over time.
Normal use over time.
Normal depletion of
paraffin, particularly in
multi-person use.
Plug is loose or damaged.
Light is burned out.
Wax was frozen during
shipment.
Unit was plugged in
before it had completely
cooled, preventing Quick
Melt cycle from activating.
WHAT TO DO
Replace the paraffin.
Replace the paraffin, using
Parabath Paraffin Refills.
Contact the Parabath
Product Dealer the unit
was purchased from or
The Hygenic Corporation
to arrange for repair.
Replace the paraffin.
Replace the paraffin.
Add additional paraffin
sufficient to raise the level
of paraffin to recommended
levels.
Reconnect the plug. If
damaged, seek qualified
repair assistance.
Contact the Parabath
Product Dealer the unit
was purchased from or
The Hygenic Corporation
to arrange for repair.
Allow the unit to operate
overnight before using.
Allow the unit to operate
overnight before using.
TroubleshooTing guide

PARABATH®
8
parabaTh uniT and aCCessories
PRODUCT AND ACCESSORIES LIST
PART NO. DESCRIPTION
24050 Parabath Unit, 110-120V, includes 6 lb. of Paraffin
24130 Paraffin Refill - Unscented, 6 lbs.
24131 Paraffin Refill - Citrus Scent, 6 lbs.
24212 High Stand
24220 Mitts
24221 Booties
24222 Liners (100 pack)
24230 Bottom Grill
24240 Testing Thermometer
24250 Replacement Lid

PARABATH®
9
WarranTy
The Hygenic Corporation warrants the Parabath Unit to the origi-
nal purchaser to be free from defects in material and workmanship
under normal usage conditions for 5 years from the date of purchase.
Purchaser’s sole remedy in any instance is limited to the repair or
replacement of the unit at warrantor’s option.
The Hygenic Corporation shall not be responsible for any incidental
or consequential damages arising out of the proper or improper use,
prescription, or maintenance of this product, and in no event shall
warrantor’s liability for such damages be greater than the purchase
price paid by the purchaser.
SERVICE OR WARRANTY REPAIR
Purchaser must obtain prior approval from The Hygenic Corporation
to return the product for repair service. Contact the manufacturer at
the return address or telephone number below to obtain service as-
sistance and/or return authorization instructions.
The Hygenic Corporation
1245 Home Avenue, Akron, Ohio 44310 USA
330-633-8460 800-321-2135 FAX: 330-633-9359
bonvital.com

PARABATH®
10
noTes
Parabath®
Paraffin Heat Therapy
CLASS I EQUIPMENT
TYPE B EQUIPMENT
Protective Earth (ground)
ATTENTION: READ OWNER’S GUIDE
120V / 120W / 60 Hz
MEDICAL EQUIPMENT
WITH RESPECT TO ELECTRIC SHOCK,
FIRE AND MECHANICAL HAZARDS ONLY
IN ACCORDANCE WITH UL 60601-1, AND
CAN/CSA C22.2 NO. 601.1
85UP

1245 Home Avenue, Akron, Ohio 44310
330-633-8460 800-321-2135 Fax: 330-633-9359
bonvital.com
Parabath®trademark is property of The Hygenic Corporation and/or its subsidiaries and may be registered in the United States and other countries.
Unauthorized use is strictly prohibited. ©2017 — Performance Health. All rights reserved. P03791 REV1
Other manuals for Parabath
1
Table of contents
Popular Medical Equipment manuals by other brands

Clinical Health Services
Clinical Health Services TENS 3N1R Instructions for use

Thoratec
Thoratec HeartMate II LVAS manual

baxter
baxter DUPLOSPRAY Quick reference manual

Synthes
Synthes Air Power Line II Instructions for use

Enabling Devices
Enabling Devices 705 user guide

Weinmann
Weinmann Homecare NP15 Instructions for use