IAS C-LCD-122-TL User manual

MESSAGE LIBRARY
Refer to BBP-5 Instal Guide for information on input triggers.
The same message may be linked to more than one trigger.
ABBREVIATED VERSION DISPLAYED IN
SELECTION SCREEN
MESSAGE DISPLAYED ON SCREEN AFTER
TRIGGER IS ACTIVATED
<Blank>
SERVICER
(Default Custom Message)
SERVICE
REQUIRED
DoorOpen Door
Open
VentMode Vent
Mode
RemoteOf Remote
Off
RemoteSh Remote
Shutdown
CleanFil Clean
Filters
ServiceR Service
Required
NoWaterF No Water
Flow
FanOverl Fan
Overload
FireShut Fire
Shutdown
ACPlantF AC Plant
Fault
HPFault HP
Fault
LPFault LP
Fault
HP/LPFau HP/LP
Fault
S1OpenCi
(Default Forced Vent Input Message)
S1 Open
Circuit
S1Closed
(Default Remote On/Off Input Message)
S1Closed
Circuit
S2Closed
(Default System Fault Input Message)
S2Closed
Circuit
Designed and Manufactured in Australia by:
Innovative Air Systems Pty Ltd.
Unit 1 / 49 Miller Street
Murarrie, Queensland, 4172.
National Sales
Ph: 1300 306 125
Product Support
Freecall: 1800 354 434
Touchpad User Guide
(Model: C-LCD-122-TL)

Page 1
Contents
The Default Display Screen
...............................................................
...........
2
The Clock Display Screen
...............................................................
.............
2
1.0 Quick Start Options
...............................................................
.................
3
2.0 Standard Menu Options
...............................................................
..........
3
2.1 To Change the Mode
...............................................................
.....................................................
3
2.2 To Set the Fan Speed (Multi fan speed models only)
...............................................................
....
4
2.3 To Change the HeatFan Setting
...............................................................
...................................
4
2.4 To Set the Run Timer (After Hours Timer)
...............................................................
.....................
4
2.5 To Edit the Setback Temperatures
...............................................................
.................................
4
3.0 To Edit the System Settings (Service Personnel Only).
......................
5
3.1 To Change the Compressor Delays
...............................................................
...............................
5
3.2 To Set the Deadband
...............................................................
.....................................................
5
3.3 To Set the Control Band
...............................................................
................................................
6
3.4 To Edit the Service Timer
...............................................................
...............................................
6
3.5 To Select the Forced Vent Input Message
...............................................................
.....................
7
3.6 To Select the Remote On/Off Input Message
...............................................................
................
7
3.7 To Select the System Fault Message
...............................................................
............................
7
3.8 To Select the Service Timer Message
...............................................................
...........................
7
3.9 To Edit the Custom Message
...............................................................
.........................................
7
4.0 Clock Menu Options
...............................................................
................
8
4.1 To Set the Clock
...............................................................
............................................................
8
4.2 To Edit the Timeclock Programs
...............................................................
....................................
8
4.3 To Set Holidays
...............................................................
..............................................................
9
4.3 To Set Daylight Savings
...............................................................
.................................................
9
5.0 Installation and Commissioning
..........................................................
10
5.1 Touchpad Dipswitch Con gurations
...............................................................
............................
10
5.2 C-LCD-122-TL Connection Diagram
...............................................................
...........................
11
The Default Display Screen
Setpoint Tem per a ture
Relay Con guration
Upper case indicates the
relay is energised.
F
= Fan
C
= Compressor
R
= Rev. Valve
R = Rev. ValveR
H
= Elect. Heat
P
= Pump
Conditioning Mode
A
= Auto
V
= Vent only
C
= Cool
H
= Heat
Operating Mode
TC
= Timeclock
RT
= Run Timer function
SB
= Setback function
22
.
5
O
c TC
O
c TC
O
FCcRR A
The Clock Display Screen
Optional Clock Mode Required
Time
Date
Year
Day
0 1 :3 1
p
M o
0 2 D e c,0 2
Page 10
0
S
0
V
V
1
V
2
A
u
x
i
l
i
a
r
y
S
o
c
k
e
t
D
I
P
S
w
i
t
c
h
e
s
D
1
D
2
V
-
V
+
T
e
r
m
i
n
a
l
T
o
u
c
h
p
a
d
P
r
o
o
f
o
f
F
l
o
w
I
n
p
u
t
.
(
S
e
e
J
P
1
n
o
t
e
s
)
H
e
a
t
i
n
g
C
o
n
t
r
o
l
A
c
t
i
v
e
F
a
n
C
o
n
t
r
o
l
A
c
t
i
v
e
C
o
o
l
i
n
g
C
o
n
t
r
o
l
A
c
t
i
v
e
H
e
a
t
i
n
g
C
o
n
t
r
o
l
A
c
t
i
v
e
2
4
0
V
A
C
L
i
n
e
i
n
F
l
o
w
P
r
o
v
e
d
L
E
D
R
e
l
a
y
5
L
E
D
R
e
l
a
y
1
L
E
D
R
e
l
a
y
2
L
E
D
R
e
l
a
y
3
L
E
D
R
e
l
a
y
4
L
E
D
J
P
1
RSP
r
e
l
a
y
1
C
1
A
N
E
N
O
5
N
C
5
C
5
F
-
F
+
D
1
D
2
V
-
V
+
S
H
S
1
N
C
1
N
O
1
C
2
N
C
2
N
O
2
O2O
C
3
N
C
3
N
O
3
C
4
N
C
4
N
O
4
O4O
r
e
l
a
y
2
r
e
l
a
y
3
r
e
l
a
y
4
r
e
l
a
y
5
f
l
o
w
t
o
u
c
h
p
a
d
s
e
n
s
o
r
0
-
1
0
V
2
4
0
V
H
e
a
t
2
H
e
a
t
1
C
o
o
l
2
C
o
o
l
1
F
a
n
S
e
n
s
o
r
A
n
a
l
o
g
u
e
O
u
t
p
u
t
2
H
e
a
t
i
n
g
A
n
a
l
o
g
u
e
O
u
t
p
u
t
1
C
o
o
l
i
n
g
A
n
a
l
o
g
u
e
O
u
t
p
u
t
C
o
m
m
o
n
BBP-5 Relay Module DIP Switch Settings
Number Function OFF
(Factory Default) ON
1Compressor
Delay
Software Selectable
(4 minute default)
4 seconds
(max)
2IAS Factory
Use Only
3IAS Factory
Use Only
4Heat Type Reverse Cycle EDH or
Cool Only
NOTES:
JP1 - remove shorting jumper from JP1, located behind
Flow Input terminals, for external proof of ow
input. Short JP1 for constant ow (no proving)
LED - The green relay LEDs when lit indicate that
the NO output for each relay is energised.The
ow LED indicates ow proved when lit.
5.2 C-LCD-122-TL Connection Diagram

Page 9
Touchpad Dipswitches when connected to earlier version
Blackbox relay modules (BB-5) for backward compatibility
Function OFF
(Factory Default) ON
1 Compressor Delay Software Selectable
(4 minute default) 4 seconds (max)
2Lock System
Settings Menu Allow Access Deny Access
3 Setpoint Range 15-30°C
(0.5°C increments)
20-25°C
(0.5°C increments)
4 Heat Type Reversing Valve Electric Duct Heat
or Cool Only
5.0 Installation and Commissioning
• Ensure all electrical connections are in accordance with the supplied connection dia-
grams and local bylaws.
• Set the Dipswitches on the back of the touchpad according to the notes and tables
below.
• Set all the system settings as mentioned in Section 3.
• If the clock module has been purchased and tted, refer to Section 4.0 to con gure
the clock and automated on/off programs, holidays and daylight savings.
• Operate the controller in heat, cool and try each fan speed setting.
• Ensure that the Delay in the Settings Menu is restored to Safety prior to nishing
commissioning.
5.1 Touchpad Dipswitch Con gurations
Some touchpads are backward compatible with earlier Blackbox versions. The touchpad
will con gure its dipwitches depending on the relay module it is connected to.
Touchpad Dipswitches when connected to
Blackbox Plus relay module (BBP-5)
Function OFF
(Factory Default) ON
1 Menu Lock Menus
Available
Menus
Locked
2 Setpoint Lock Setpoint
Adjustable
Setpoint
Locked
3 Setpoint Range 15-30°C
(0.5°C increments)
20-25°C
(0.5°C increments)
4 On/Off Lock On/Off
Available
On/Off
Locked
Page 2
1.0 Quick Start Options
This controller provides a menu based user interface. The information that can be
displayed at any given time is limited by the screen area of 2x8 character lines. Additional
options are viewed by using the arrow buttons to scroll the information across the screen.
The ashing cursor indicates the active area of the screen (generally the top line of the
display). Pressing the enter button will activate the selection highlighted by the ashing
cursor.
• To change the setpoint, press the arrow buttons. Once the required temperature has
been set the screen will revert to the default display after a short period (see image page 1).
• All standard menu options are accessible by pressing menu at the default display
screen.
• All clock menu options (clock module required) are accessible by pressing menu at
the clock display screen.
• Press the clock button to switch between the default display screen and the clock
display screen.
• The menu button when pressed will access the various menu screens.
• While in the menu screens the menu button, when pressed, takes you back one step.
• The enter button when pressed moves forward through the various screens, selecting
options and saving settings.
• The current active settings appear in CAPITALS.
• The arrow buttons, when pressed in a menu will either cycle the cursor and scroll the
screen through the various options available, or, alter the value of the selected variable.
• Press and hold the arrow button to quickly scroll the selected variable.
2.0 Standard Menu Options
While viewing the default display screen press the menu button to gain access to the
standard menu options. Use the arrow buttons to cycle the cursor to the desired menu
option, then press the enter button to select that option.
Pressing the menu button (or selecting ‘Exit’ then pressing enter) will exit the current
selection if required.
2.1 To Change the Mode
Operation: The Mode controls the operation of the A/C system. Available options are Cool, Heat,
Vent or Auto (automatically switches between cooling and heating as required)
• Select ‘Set Mode’ from the standard menu options screen (see section 2.0) and the
mode selection screen will appear. (Quick Tip: Press menu, down, enter)
• Scroll down with the down arrow to select the required operating mode.
• Press the enter button to save the new value and return to the default display screen.

Page 3
2.2 To Set the Fan Speed (Multi fan speed models only)
Operation: The Fan Speed enables the user to manually select the fan speed or set the fan to
Auto. In Auto mode the fan speed decreases as the temperature approaches setpoint.
• Select ‘FanSpeed’ from the standard menu options screen.
• Use the arrow buttons to move the cursor to the required fan speed setting.
• Press the enter button to save the new value and return to the default display screen.
2.3 To Change the HeatFan Setting
Operation: HeatFan controls the indoor fan operation in heating mode. In ‘Contin’ mode the fan
will run whenever the system is On. In ‘Auto/Cyc’ mode the fan will cycle off between heating calls.
Electric Duct Heating is protected by 60 second fan run-on.
• Select ‘HeatFan’ from the standard menu options screen and press enter.
• Use the arrow buttons to move the cursor to the required setting.
• Press the enter button to save the new value and return to the default display screen.
NOTE: The fan can never cycle off in cool mode or during a cool or heat call.
2.4 To Set the Run Timer (After Hours Timer)
Operation: With the Run Timer enabled, and if the system is off (and outside any timeclock
periods), pressing the On/Off button will start the system in Run Timer Mode. The system will run
for the duration of time set in the Run Timer, after which the system will turn itself off.
• Select ‘RunTimer’ from the standard menu options screen and press enter, the run
timer edit screen will appear.
• The cursor will highlight the minutes space.
• Use the arrow buttons to alter the hours shown (in ten minute increments) to the re-
quired period (up to 24 hours).
• Press and hold the arrows to scroll numbers quickly.
• Press the enter button to save the new value and return to the default display screen.
To disable the Run Timer, select the minimum value of “-----” and press enter.
NOTE: The Run Timer status can be determined from the standard menu options screen. If the
Run Timer is enabled, ‘RUNTIMER’ will appear in CAPITAL letters in this screen.
2.5 To Edit the Setback Temperatures
Operation: Setback is used to maintain temperature within preset limits at all times. If the
temperature moves outside these limits the Controller will turn the system On and heat or cool as
required to keep the temperature within the preset limits. These limits are separate and distinct
from the normal setpoint.
CAUTION: When activated, Setback will cause the system to start irrespective of any timer
programs including holidays. Pressing the Off button WILL NOT stop the system if running in
Setback Mode.
Page 8
NOTE: Active Programs (i.e. programs with a start or stop time or both, AND with active days) will
appear in CAPITALS. (E.g. “PROG 02” = active; “prog 02” = not active)
4.3 To Set Holidays
NOTE: Active Holidays (i.e. ONLY holidays with a start AND stop date) will appear in CAPITALS.
Active Holidays will cause the system to ignore timeclock switching (on and off).
Holidays may be set as single days, or as blocks.
DATES ARE INCLUSIVE AND ALL HOLIDAY PROGRAMS MUST HAVE A START AND STOP
DATE ENTERED OR THEY WILL BE INVALID. FOR A ONE DAY HOLIDAY, MAKE THE START
AND STOP DATE THE SAME.
• Select ‘Set Hols’ from the timeclock menu options screen (see Section 4.0) then
press enter and the set holiday edit screen will appear.
• The cursor will highlight ‘Exit’. Use the arrow buttons to select the Holiday program to
be edited, then press enter to move to the set start date screen.
• The cursor will highlight the Month value. Use the arrow buttons to select the correct
Month , then press enter.
• Repeat this procedure for the Day value which completes setting the start date for the
holiday.
• The display will change to the set stop date screen.
• Repeat the steps detailed above to set the required stop date for the holiday.
• The display will revert to the set holiday edit screen and the cursor will highlight the
last holiday edited.
• To return to the clock display screen, simply use the arrows to navigate back up to
the ‘Exit’ options and press the enter button.
• To enter more holidays, use the arrow buttons to select another holiday entry and
repeat the entire process.
• To disable a holiday setting, program it’s date to “----”.
4.3 To Set Daylight Savings
Operation: The daylight savings function advances the clock’s time by 1 hour whilst the
current date and time are between the start and stop dates set. (E.g. Southern Hemisphere =
Oct31...Mar31; Northern Hemisphere = Mar31...Oct31)
• Select ‘Day Save’ from the timeclock menu options screen (see Section 4.0) then
press enter and the start daylight savings edit screen will appear.
• Use the arrow buttons to select the correct Month , then press enter.
• Repeat this procedure for the Day value which completes setting the start date for the
daylight savings.
• The display will change to the set stop daylight savings screen.
• Repeat the steps detailed above to set the required stop date for the daylight savings.
To disable daylight savings, simply select a start date of “----” or start & stop in the same month.
NOTE: The 1 hour advance happens at 1:59am (the next minute is 3:00am) and the 1 hour back
happens at 2:59 (next minute is 2:00am).

Page 7
4.0 Clock Menu Options
NOTE: This clock section is only relevant if the optional clock module has been plugged in to the
relay module. The clock module CAN BE plugged in (and removed) while the relay module is
powered up and running.
• From the default display screen press the clock button to enter the clock display
screen.
• While the clock display screen is displayed press the menu button to enter the
timeclock menu options screen.
• Use the arrow buttons to cycle the cursor to the desired menu option, then press the
enter button to move to the edit screen for that menu option.
4.1 To Set the Clock
• Select ‘SetClock’ from the timeclock menu options screen (see Section 4.0) then
press enter and the set clock edit screen will appear.
• The cursor will highlight the Hour value. Use the arrow buttons to select the correct
hour (watch for am/pm), then press enter.
• Repeat this procedure for the Minutes, Day, Month and Year values.
• After pressing enter on the Year, the display will return to the clock display screen.
4.2 To Edit the Timeclock Programs
• Select ‘SetProgs’ from the timeclock menu options screen (see Section 4.0) to go to
the set program edit screen. The cursor will highlight ‘Exit’.
• Use the arrow buttons to select the timeclock program to be edited, then press enter
to move to the set start time screen.
• The cursor will highlight the minutes value. Use the arrow buttons to select the
correct time in 10 minute increments, then press enter.
• The display will then change to the set stop time screen.
• Follow the same procedure as detailed above to set the stop time then press enter.
• The display will then change to the set run days screen. This is the screen at which
you de ne the days that are going to use these start and stop times. Use the arrow
buttons to toggle between UPPER and lower case.
• The cursor will highlight the rst letter on the bottom line, representing Sunday. These
letters “SMTWTFS”, when made UPPER CASE, attach the start and stop times to
that day of the week. To ignore the start and stop times on a particular day, make the
corresponding letter lower case. Press enter to save and move the cursor to the next
letter.
• Repeat the procedure detailed above for each day of the week. Press menu to go
back one letter if required.
• Pressing enter after Saturday will return the display to the set programme edit screen
and the cursor will be highlighting the last edited program.
• To return to the clock display screen, simply use the arrows to navigate back up to
the exit options and press the enter button.
• To enter more programs, use the arrow buttons to select another program and repeat
entire process.
To disable a program, select a start & stop time of “--:--”.
Page 4
To disable Setback, select a minimum of “----” and a maximum of “----”. These “----” settings are
found by scrolling the minimum all the way down, and the maximum all the way up.
• Select ‘Setback’ from the standard menu options screen and the setback edit screen
will appear.
• The cursor will highlight the minimum temperature value.
• Use the arrow buttons to alter the value to the required temperature (in 1°C increments).
• Press enter to save and the cursor moves to the maximum temperature value.
• Use the arrow buttons alter the value to the required temperature (in 1°C incre-
ments).
• Press enter to save and return to the default display screen.
NOTE: The setback function is enabled whenever there is at least one valid limit set as detailed
above. The setback temperatures are to be linked to setpoint in the following manner:
• The highest minimum setback temperature allowed is SETPOINT MINUS 2°C
• The lowest maximum setback temperature allowed is SETPOINT PLUS 2°C
• The Setback Range is from 5 - 50°C.
3.0 To Edit the System Settings (Service Personnel Only).
Changing these settings may adversely affect system operation and in extreme cases may
cause system damage.
• Select ‘Settings’ from the standard menu options screen and press enter to access
the settings sub-menu screen.
• The line ‘CAUTION!’ will alternate with ‘Service’ and ‘use only’.
• Press either arrow button to scroll the cursor from ‘Exit’ to ‘Proceed’ then press enter
to access the settings sub-menu screen .
3.1 To Change the Compressor Delays
Operation: The compressor delays dictate the length of time that the compressor must remain on
or off after cycling.
• Select ‘Delays’ from the settings sub-menu screen, then press enter to access the
delay select screen.
• The current Delay setting is displayed in CAPITALS.
• Use the arrow buttons to highlight the required Delay setting.
• Press enter to save and the display will return to the settings sub-menu screen.
The following options are available for Compressor Delays:
Safety = 4 minutes (minimum) Extended = 40 seconds (minimum)
Standard = 4 seconds (minimum) Instant = 1 second (min), 4 seconds (max)
3.2 To Set the Deadband
Operation: A deadband value other than 0 will create separate Heating and Cooling setpoints (half
of the deadband value either side of the displayed setpoint).

Page 5
• Select ‘Deadband’ from the settings sub-menu screen, then press enter to access
the deadband edit screen .
• The cursor will highlight the deadband value.
• Use the arrow buttons to alter the value in 1°C increments from 0 to 3.
• Press enter to save and return to settings sub-menu screen.
3.3 To Set the Control Band
Operation: Control Band is a common variable covering both Stage Separation and Switching
Differential. There is a separate control band for Heating and Cooling working from the heating and
cooling setpoints dictated by the DEADBAND.
• Highlight ‘CtrlBand’ from the settings sub-menu screen, then press enter to access
the control band edit screen.
• The cursor will highlight the Heating value.
• Use the arrow buttons to change the value.
• Press enter to save the value and move the cursor to the Cooling value. Now change
this value by using the arrow buttons.
• Press enter to save and return to the settings sub-menu screen.
SINGLE STAGE CONTROLLERS: The control band for single stage controllers is adjustable in
0.5°C increments from 0.5°C to 1.5°C, resulting in a switching differential equal to the control band
value and stage separation also equal to the control band value.
TWO STAGE CONTROLLERS: The control band for two stage controllers is adjustable in 1.0°C
increments from 1.0°C to 3.0°C, resulting in a switching differential for each stage equal to half the
control band value and stage separation equal to half the control band value.
THREE STAGE CONTROLLERS: The control band for three stage controllers can either be
1.5°C or 3.0°C, resulting in a switching differential for each stage equal to 1/3 the control band
value and stage separation equal to 1/3 the control band value.
3.4 To Edit the Service Timer
Operation: The Service Timer monitors system run time and at the end of the timer period displays
a message (see 3.8 page 6) and gives an audible warning (2 beeps every 16 seconds). Press any
button to silence the audible warning.
• Select ‘SvcTimer’ from the settings sub-menu screen, then press enter to access the
service timer edit screen .
• Use the arrow buttons to move the cursor to highlight ‘Set’. Press the enter button
and the cursor will highlight the number of hours. Use the arrow button to change the
hours shown in increments of 10 hrs.
• Press enter and the Service Timer will reset and the cursor will move back to high-
light ‘Set’.
• Press menu to return to the settings sub-menu screen.
• To disable the service timer, select a set time of “----”.
NOTE: The Due Value is the time remaining until the Service Timer message appears on the
display. This value will revert to the Set Value when the above procedure is followed.
Page 6
3.5 To Select the Forced Vent Input Message
• Select ‘Msg S1op’ from the settings sub-menu screen and press enter.
• The screen will display the abbreviated message library, with the cursor highlighting
the current selection.
• Press the arrow buttons to scroll to the required selection then press enter.
Refer to the message library table on the back page for the complete list of available messages
and their abbreviations. Refer to the BBP-5 Installation Manual for information on input triggers.
3.6 To Select the Remote On/Off Input Message
• Select ‘Msg S1cl’ from the settings sub-menu screen and press enter.
• The screen will display the abbreviated message library, with the cursor highlighting
the current selection.
• Press the arrow buttons to scroll to the required selection then press enter.
3.7 To Select the System Fault Message
Operation: The input trigger for the System Fault Message (S2 closed circuit), when activated,
displays the message and causes the touchpad to emit an audible warning (2 beeps every 16
seconds). Press any button to silence the audible warning.
• Select ‘Msg S2cl’ from the settings sub-menu screen and press enter.
• The screen will display the abbreviated message library, with the cursor highlighting
the current selection.
• Press the arrow buttons to scroll to the required selection then press enter.
3.8 To Select the Service Timer Message
• Select ‘MsgTimer’ from the settings sub-menu screen and press enter.
• The screen will display the abbreviated message library, with the cursor highlighting
the current selection.
• Press the arrow buttons to scroll to the required selection then press enter.
3.9 To Edit the Custom Message
• Highlight ‘Edit Msg’ and press enter.
• The display will show ‘SERVICE REQUIRED’ and the cursor will highlight the rst
letter. Using the arrow buttons, select the alphanumeric symbol required then press
enter to save and move to the next letter. (Press menu to go back, if required.)
• Repeat until the both 8 character lines are complete.
• Press enter to save and return to settings sub menu screen.
Table of contents
Popular Touch Panel manuals by other brands

Maple Systems
Maple Systems Silver Plus Series Installation and operation manual

Advantech
Advantech PPC-57 Series manual

Maple Systems
Maple Systems PC100 Series Operation manual

IEI Technology
IEI Technology AFL2-15A-H61 series user manual

LS
LS iXP2-08 A Series installation guide

Crestron
Crestron TPMC-4SMD-FD Installation & operation guide