Table 4. PCIe slot locations and descriptions for the 8247-42L system (continued)
Slot Location
code
Description PHB Adapter
size
Slot capabilities Slot availability
CAPI SR-IOV Dynamic
direct
memory
access
(DMA)
window
I/O adapter
enlarged
capacity
assign
order
8247-42L
no GPU
adapter
(1
processor)
8247-42L
no GPU
adapter
(2
processors)
8247-42L
with GPU
adapter
(2
processors)
Slot 10 P1-C112PCIe3, x8 PCIe3
Switch 1,
S0P1
Full-height,
half-length
or short
(low-profile)
No No Yes 7 Yes Yes Yes
Slot 11 P1-C122, 6 PCIe3, x8 PCIe3
Switch 1,
S1P9
Full-height,
half-length
or short
(low-profile)
No Yes Yes Default Yes Yes Yes
1Slot is a direct slot from the Processor Module and is a high-performance slot. The connectors in these slots are differently colored than the slots from the PCIe3 switches.
2Slot connected by the PCIe3 switches.
3One PCIe gen3 x16 graphics processing unit (GPU) adapter (FC EC47 or EC4B) is preinstalled in slot 5 (P1-C6). The GPU adapter requires two slot space for accommodating
the air baffle.
4The I/O Adapter Enlarged Capacity assignment order value is 5 for one processor or 10 for two processors.
5The I/O Adapter Enlarged Capacity assignment order value is 6 for one processor or 8 for two processors.
6For platforms with less than 64GB of total system memory, SR-IOV should not be configured in these slots as performance may be severely impacted.
vAll slots are PCIe generation 3 slots.
vThe peak bandwidths supported by the x16 slots are 16 gigabytes per second (GBps) in simplex mode and 32 GBps in duplex mode.
vThe peak bandwidths supported by the x8 slots are 8 GBps in simplex mode and 16 GBps in duplex mode.
vRegular full-height adapters can be installed only in the full-height, full-length slots 2, 4, 5, and 6.
vThe full-height, half-length or short (low-profile) adapters can be installed in slots 1, 3, 7, 8, 10, and 11.
vAll slots support enhanced error handling (EEH).
vAll PCIe slots are hot swappable and support concurrent maintenance.
PCIe adapters placement rules
Use this information while selecting slots for installing PCIe adapters in the 8247-42L system. Use Table 5
on page 5 to identify slot placement priorities in the system and the maximum number of adapters that
can be installed in the system.
1. IBM Manufacturing requires that slot P1-C10 hold a local area network (LAN) adapter to install and
test the server. One LAN feature code (FC) 5899, EN0W, EL55, or EN0S should be selected for this
purpose. IBM ships the LAN adapter in the P1-C10 slot. If needed, the client can move the LAN
adapter to a different slot allowing other PCIe adapters to be placed in P1-C10. The following tables
assume that the LAN adapter remains in the P1-C10 slot.
2. The PCIe3 cable adapter (FC EJ08) is supported in slots P1-C3, P1-C6, P1-C5, and P1-C7 on 8247-42L
systems that do not have a GPU adapter installed.
3. Slots P1-C3, P1-C5, P1-C6, and P1-C7, are x16 slots with busses direct from the Processor Modules
and can be used to install high-performance PCIe adapters. For these full-height, full-length slots, first
priority must be given to GPU adapters followed by PCIe x16 adapters, CAPI adapters, Single Root
IO Virtualization (SR-IOV) capable adapters, FC EJ12 (FPGA Accelerator), high-performance adapters,
ending with all other supported adapters.
4. CAPI accelerator adapters are supported in slots P1-C6, P1-C7, P1-C3, and P1-C5.
5. Slots P1-C2 and P1-C4 are x8 slots with busses direct from the Processor Modules and can be used to
install high-performance PCIe adapters.
6. Slots P1-C2, P1-C3, P1-C4, P1-C5, P1-C6, and P1-C7 are slots with busses direct from the Processor
Modules and can be used to install high-performance PCIe adapters that support the Single Root IO
Virtualization (SR-IOV) function.
7. PCIe internal slots P1-C14 and P1-C15 are used to install the SAS RAID adapter FC EJ0S and the
internal SAS RAID adapter (CCIN 57D8).
4Power Systems: PCIe adapter placement for the 8247-42L, 8286-41A, or 8286-42A