manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ICM Controls
  6. •
  7. Surge Protector
  8. •
  9. ICM Controls ICM516 User manual

ICM Controls ICM516 User manual

Other ICM Controls Surge Protector manuals

ICM Controls ICM518 General instructions

ICM Controls

ICM Controls ICM518 General instructions

ICM Controls ICM531 General instructions

ICM Controls

ICM Controls ICM531 General instructions

ICM Controls ICM533 General instructions

ICM Controls

ICM Controls ICM533 General instructions

ICM Controls ICM530 General instructions

ICM Controls

ICM Controls ICM530 General instructions

Popular Surge Protector manuals by other brands

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

Philips

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

M-system MMA instruction manual

M-system

M-system MMA instruction manual

CyberPower CSP600WSU user manual

CyberPower

CyberPower CSP600WSU user manual

UTP BALUN SP-VD08 user manual

UTP BALUN

UTP BALUN SP-VD08 user manual

ELAC ProteK PR91-W Setup guide

ELAC

ELAC ProteK PR91-W Setup guide

Tsubaki TSM4000M1 instruction manual

Tsubaki

Tsubaki TSM4000M1 instruction manual

CyberPower B1006T user manual

CyberPower

CyberPower B1006T user manual

QVS PP134C Specification sheet

QVS

QVS PP134C Specification sheet

Davis Instruments Radio Surge Protector user guide

Davis Instruments

Davis Instruments Radio Surge Protector user guide

CyberPower B300WRC1 user manual

CyberPower

CyberPower B300WRC1 user manual

M-system MGD-24 instruction manual

M-system

M-system MGD-24 instruction manual

Panamax MAX 5400-EX owner's guide

Panamax

Panamax MAX 5400-EX owner's guide

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

OBO Bettermann

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

CyberPower CSP604T user manual

CyberPower

CyberPower CSP604T user manual

CyberPower CSP706T user manual

CyberPower

CyberPower CSP706T user manual

Mitsubishi Electric LITOL LTM-125RF manual

Mitsubishi Electric

Mitsubishi Electric LITOL LTM-125RF manual

Intermatic PS3000 installation instructions

Intermatic

Intermatic PS3000 installation instructions

Siemens SICROWBAR 7VV3003 operating instructions

Siemens

Siemens SICROWBAR 7VV3003 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SPECIFICATIONS
Service Voltage: 120/240 Volt Single Phase
Maximum Surge Current: 100,000 Amps
Maximum Energy Dissipation: 1,020 Joules
Installation Point: Electrical Panel, Electrical Disconnect
Diagnostics: Green light indicates surge
suppression present
AC Protection Modes: L-L, L-G
Conduit Connection: 3/4” Weight: 0.33 lbs.
LIMITED LIFETIME PROTECTION WARRANTY
ELECTRICAL SHOCK HAZARD
– Before installing this unit, turn off power at the main service
panel by removing the fuse or switching the appropriate circuit breaker to the OFF position.
BXB78
LIMITED LIFETIME PROTECTION WARRANTY
Review enclosed warranty information for full details & registration information
The ICM516 is UL Rated as a Type 2 device and must be installed prior to the equipment it is intended to protect. It can be
installed at the A/C disconnect or an indoor electrical panel. Suitable for use on a circuit capable of delivering not more than
10,000 rms symmetrical amperes, 240V max, when protected by a circuit breaker rated 30A maximum and 240V minimum.
Device wires should be kept at a minimal length to increase response time and effectiveness of the control.
Mounting Instructions
1. Turn off the main breaker and/or main power to the service disconnect.
2. Remove the cover on service disconnect or the electrical panel.
3. Mount the unit using the self-tapping screws to inside of service disconnect.
4. If mounting through conduit connection of electrical panel inside home:
4.1 Remove the retaining ring on the unit.
4.2 Feed the wires into the electrical panel service disconnect.
4.3 Re-secure the retaining ring.
5. Route the green wire to the grounding lug and secure.
6. Connect the two black wires.
– For electrical panel: Connect to closest
two-pole breaker.
– For A/C disconnect: Connect to the
disconnect power terminals.
7. Restore power; LED(s) should be on w/ 120
VAC present from black to green.
8. Close electrical panel or cover.
240 VAC Wiring
Black on hot leg
Black on hot leg
Green on earth ground
Maintenance Test Procedure (to be performed by a licensed
contractor/electrician only): Apply 120V from each Black to Green
wire; both LEDs should illuminate. If only one LED, or neither LED
lights, the product needs to be replaced.
120 VAC Wiring
Black on hot leg
Black on neutral leg
Green on earth ground
Device is intended to be connected only to panel connection. All wiring must conform to national, state
and local electrical codes. 14AWG wire or larger required. Product contains no serviceable parts.
ICM516
SURGE PROTECTIVE DEVICE
Indoor Electrical
Panel Installation
Dimensions / Mounting Orientation
A/C Disconnect
Installation
F
U
S
E
F
U
S
E
B
B
R
B
G
Ground
http://waterheatertimer.org/How-to-wire-Whole-house-surge-protector.html