GENERAL WARNINGS
A warning indicates a possible hazard to personnel, which may cause injury. Observe the following general warnings
when using or working on this equipment:
1. Heed all warnings on the unit and in the operating instructions.
2. Do not use this equipment in or near water.
3. This equipment is grounded through the grounding conductor of the power cord. To avoid the risk of electric
shock, this equipment must only be connected to a supply mains with protective earth.
4. Route power cords so they are not likely to be damaged.
5. Disconnect power before cleaning the equipment. Do not use aerosol cleaners, use a damp cloth.
6. Dangerous voltages may exist at several points in this equipment. To avoid injury, do not touch exposed
connections and components while power is on.
7. Do not wear rings or wristwatches when troubleshooting the equipment.
8. To avoid fire hazard, use only specified fuse(s) with the correct type number, voltage, and current ratings as
referenced on the equipment. Qualified service personnel should replace fuses.
9. Not intended to be used in an Oxygen Rich Environment. Not suitable for use in the presence of a flammable
anesthetic mixture with air or with oxygen or nitrous oxide.
10. Qualified service personnel should perform safety checks periodically and after any service.
11. If the equipment is modified, appropriate inspection and testing must be conducted to ensure continued safe use
of equipment.
12. Keep the back of the unit away from the patient vicinity (which is commonly defined as the space within 1.8m/6
feet of the patient/operating table), or otherwise be generally inaccessible to the patient.
13. Use only smoke evacuator accessories manufactures by I.C. Medical, as SAFEGUARD BLUE®Hydrophobic
ULPA Filter with Built-in Fluid Trap, Large Coconut Charcoal Output Filter, RF Sensor(s), smoke tubing
disposable and other accessories.
14. Using any other filters, sensors, or accessory, not manufactured or supplied by I.C. Medical, may cause
damage and/or cause the system to be inoperable and may void the warranty.
15. Do not operate unit without SAFEGUARD BLUE®Hydrophobic ULPA Filter with Built-in Fluid Trap (for a
complete list of products contact I.C. Medical sales representative).
16. To prevent contamination and for proper operation I.C. Medical SAFEGUARD BLUE®Hydrophobic ULPA
Filter must be properly installed and used at all times.
17. Do not operate machine without Large Coconut Charcoal Output Filter.
18. Turn OFF the unit when replacing the Large Coconut Charcoal Output Filter. Replace the Large Coconut
Charcoal Output Filter as soon as odors become noticeable, or every three months, whichever occurs first.
19. Do not block exhaust.
CONTRAINDICATIONS
A contraindication is a specific situation in which a drug, procedure, or surgery should not be used because it may be
harmful to the person. Observe the following contraindications when using or working on this equipment.
DO NOT use this device for the suction of liquids.
GENERAL CAUTIONS
A caution indicates a possible hazard to equipment that could result in equipment damage. Observe the following
cautions when operating or working on this equipment.
1. When installing this equipment, do not attach the power cord to building surfaces.
2. To prevent damage to equipment when replacing fuses, locate and correct the problem that caused the fuse to
blow before re-applying power.
3. Use only specified replacement parts.
4. Use only smoke evacuator accessories manufactured by I.C. Medical, as SAFEGUARD BLUE® Hydrophobic
ULPA Filter with Built-in Fluid Trap, Large Coconut Charcoal Output Filter, RF Sensor(s), smoke tubing
disposable and other accessories. Using any other filters, sensors, or accessory, not manufactured or supplied by
I.C. Medical, may cause damage and/or cause the system to be inoperable and may void the warranty.
5. Follow precautions for static sensitive devices when handling this equipment.