ICP iMAT 32VBI-ELV User guide

EN-US - english US
Instructions for installation and operation
Condensate drain
¡MAT 32VBI-ELV
01-2825

2 iMAT 32VBI-ELV
Dear customer,
Thank you for deciding in favor of the iMAT 32VBI-ELV condensate drain. Please read the installation and
operating instructions carefully before mounting and starting up the iMAT 32VBI-ELV, and follow our
directions. Perfect functioning of the iMAT 32VBI-ELV, and thus reliable condensate discharge, can only be
guaranteed when the provisions and notes stipulated here are strictly adhered to.

iMAT 32VBI-ELV 3
1 Pictograms and symbols ........................................................................................................................4
2 Safety instructions..................................................................................................................................4
3 Proper use..............................................................................................................................................6
4 Exclusion from the scope of application.................................................................................................6
5 Technical data ........................................................................................................................................7
6 Electrical data.........................................................................................................................................8
7 Dimension drawing.................................................................................................................................9
8 Function................................................................................................................................................10
9 Installation ............................................................................................................................................13
10 Electrical installation.............................................................................................................................16
11 Control and maintenance .....................................................................................................................19
12 Troubleshooting and fault elimination ..................................................................................................23
13 Elements and components...................................................................................................................24
14 Recommended spare parts..................................................................................................................24

Pictograms and symbols
4 iMAT 32VBI-ELV
Pos: 1/ Beko Technisc heD okumentation/Ü berschriften/1/Pi ktogramme und Symbol e @1 \mod_1290773 595840_15098.doc x@ 2 0525 @ 1 @ 1
1Pictograms and symbols
Pos: 2 / Beko Tec hnisc he D okum entatio n/Piktogram me/Anleit ung beacht en blau @ 0 \ mod_1213 268300 255_1509 8.docx @ 15193 @ @ 1
Observe the installation and operating instructions
Pos: 3 / Beko Tec hnisc he D okum entatio n/Piktogram me/Anleit ung beacht en s/ w Typensc hild @ 1\mod_ 129077 21801 42_150 98.docx @ 20492 @ @ 1
Observe the installation and operating instructions
(on the type plate)
Pos: 4/ Beko Technische Dokum entation/Piktogramme/ Gefahr Warnung Vorsicht s/w @ 0\mod_ 1213265685174_ 15098.docx @ 15189 @ @ 1
General danger symbol (danger, warning, caution)
Pos: 5/ Beko Technisc heD okumentation/Pi ktogramme/G+W+ VN etzspannung s/ w@ 0\mod_1213266193701_150 98.docx @ 15191 @ @ 1
General danger symbol (danger, warning, caution) for supply voltage and supply voltage-
carrying plants components
Pos: 6/ Beko Technische Dokum entation/Überschriften/1 /Sicherheitshinw eise@ 0\m od_11836376092 61_15098.docx @ 15102 @ 1 @ 1
2 Safety instructions
Pos: 7 / Beko Tec hnisc he D okum entatio n/Global e T exte/Allg emeiner H i nweis BM @ 0\mo d_118361 573731 3_15098 .docx @ 1509 9 @ @ 1
Pos: 8 / Beko Tec hnisc he D okum entatio n/Sicherh eit/Hin weis A nleitung mitDocVar als Fir menname @ 8\m od_140 50627803 58_15 098.doc x @ 41 099 @ @ 1
Please check whether or not these instructions correspond to the device type.
Adhere to all advice given in these operating instructions. They include essential information
which must be observed during the installation, operation and maintenance. Therefore it is
imperative for the service technician and the responsible operator / technical staff to read these
operating instructions prior to installation, start-up and maintenance.
The operating instructions must be accessible at any time at the place of application of the
iMAT 32VBI-ELV.
In addition to these operating instructions, local or national regulations must be complied with,
if necessary.
Make sure that the iMAT 32VBI-ELV is operated only within the permissible limit values
indicated on the type plate. Any deviation involves a risk for persons and materials, and may
result in malfunction and service failures.
If you have any queries regarding these installation- and operating instructions, please contact
Independent Compressor Partners.
Pos: 9/ Beko Technische Dokum entation/Sicherheit/Ge fahrDru ckluft @ 0\mod_11841 48143854_15098.doc x@ 1512 1@ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which are
not secured.
Pos: 10 /BekoT echnische Doku mentation/Sicherheit/Ma ßnahmen Druckluft BM @ 0\mod_1 184148284291_1509 8.docx @ 15123 @ @1
Measures:
• Do not exceed the maximum operating pressure (see type plate).
• Only carry out service measures when the system is pressure less.
•Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant
pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos: 11 /Beko Technisch eD okumentation/Sic herheit/Gefa hrNe tzspannung 1 s/w @ 0\m od_11841481869 48_15098.docx @ 151 22@ @ 1

Safety instructions
iMAT 32VBI-ELV 5
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos: 12 /BekoT echnische Doku mentation/Sicherheit/Ma ßnahmen Netzspannung BM31U/3 2U/33U @ 7\mod_139046719 7804_15098.docx @ 38070 @ @ 1
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
•When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
• The removed control unit has no IP degree of protection.
•All types of electrical works must be carried out by authorized and qualified personnel only.
Pos: 13 /Beko Technisch eD okumentation/Sic herheit/Sicherh eitshinweise, weit ereBM ( nicht Ex, nicht IF) @ 0\mo d_1183616103770_ 15098.docx @ 15100 @ @ 1
Further safety instructions:
• For installation and operation, the national regulations and safety codes in force must also be adhered
to.
• Do not use the iMAT 32VBI-ELV in hazardous areas.
• Regarding the inlet screw joints, excessive tightening forces must be avoided. This applies in particular
to conical screw joints.
• The iMAT 32VBI-ELV will only function when voltage is applied.
• Do not use the test button for permanent drainage.
• Use genuine spare parts only. This is imperative to ensure perfect functioning.
Pos: 14 /Beko Tec hnisch e D oku mentation/Sic herhei t/Zusatz Sicherh eitshi nweise BM3 1/32 SA + 31U /32U SA @ 0\mod_ 1185 35149699 3_15098.d ocx @ 15150 @ @ 1
Additional advice:
• The removed control unit has no IP degree of protection.
• During installation, use spanner flat at the feed pipe (wrench size SW27) as a back rest.
• The service unit must not be dismantled.
Pos: 15 /BekoT echnische Doku mentation/Sicherheit/Vorsi chtF ehlfunktion @ 0\mod_121 4378096290_1509 8.docx@ 1 5237 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
iMAT.
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos: 16 /Beko Tec hnisch e D oku mentation/Sic herhei t/Maßnahm en F ehl funktione n BM @ 0 \mod_1 2143784 3402 5_15098.doc x @ 15238 @ @1
r
Measures:
• Condensate drainage which is reliable in performance directly optimizes the compressed-air quality.
• To prevent damage and breakdowns, it is imperative to observe the following:
• Exact compliance with the specifications of use and with the performance parameters of the iMAT,
in connection with the case of application (see "Proper use" section)
• Exact compliance with the installation- and operation instructions in this manual
• Regular maintenance and control of the iMAT in accordance with the instructions in this operating
manual
Pos: 17 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Proper use
6 iMAT 32VBI-ELV
Pos: 18 /Beko Technisch eD okumentation/Üb erschriften/1/B estimmungsgem äßeV erwendung @ 0\mo d_118363770629 3_15098.docx @ 1510 3@ 1 @ 1
3 Proper use
Pos: 19 /Beko Tec hnisch e D oku mentation/B estimm ungsgem äße V er wendung/ BEKOM AT/Besti mmung. Ver wend. BM 31/32 /33 +U @0\m od_12133 45398718 _15098. doc x @ 15218 @ @ 1
• The iMAT 32VBI-ELV is an electronically level-controlled condensate drain for compressed-air plants.
• The device is employed within the permissible performance parameters (see "Technical data").
• The iMAT 32VBI-ELV is able to drain condensate under operating pressure from the plant components
virtually without compressed-air loss.
• For its function, the iMAT 32VBI-ELV requires an supply voltage and an operating pressure (see
"Technical data").
• As far as the employment in plants with increased demands on compressed air is concerned (food
industry, medical technology, laboratory equipment, special processes etc.), the operator must decide
on measures for the monitoring of the compressed-air quality. These have an effect on the safety of the
subsequent processes and may prevent damage to persons and plants.
• It is the task of the operator to ensure that the indicated conditions are met during the entire operating
time.
Pos: 20 /Be ko T echnis che Do kumentati on/Besti mmungsg emäß e V er wendung/ BEKOM AT/Bes timmu ng. Verwen d. BM Vario ( Z usatz) @ 0\mod _1185 783975 983_1509 8.docx @ 15 162 @ @ 1
• The iMAT Vario is a condensate drain whose properties are adjusted especially to prescribed
applications.
• iMAT Vario devices must not be employed at drain points other than those prescribed by the supplier,
as this may result in malfunction and damage in the compressed-air system and at the compressed-air
consumers.
• iMAT Vario devices must not be replaced by other iMAT-types, as this may result in malfunction and
damage in the compressed-air system and at the compressed-air consumers.
Pos: 21 /BekoT echnische Doku mentation/Überschriften/ 1/Ausschluss vom Anwend ungsbereich @ 0\mod_123 6003439359_15098.d ocx@ 1 5308@ 1 @ 1
4 Exclusion from the scope of application
Pos: 22 /Beko Tec hnisch e D oku mentation/B estimm ungsgem äße V er wendung/ BEKOM AT/Ausschl uß Anwend ung BM 31/32/3 3 +U @0\mod _123 60038375 11_15098. doc x @ 153 09 @ @ 1
• The iMAT 32VBI-ELV as a condensate drain alone cannot guarantee a defined compressed-air quality,
for this purpose, other additional technical devices are required.
• iMAT 32VBI-ELV is not suitable for use in plants carrying vacuum or atmospheric ambient pressure or
in ex-areas.
• The iMAT 32VBI-ELV must not be exposed to permanent direct solar or thermal radiation.
• The iMAT 32VBI-ELV must not be installed and operated in areas with an aggressive atmosphere.
Pos: 23 /B eko T echnisch e Do kumentati on/Bestim mungsgemäß e Ver wendung/ BEKOMAT/ Ausschluß Anw endung BM nic ht für frostg efährdete Bereic he (Zu satz) @ 0 \mod_1 21610643 9206_15098.d ocx @ 1 5249 @ @ 1
• The iMAT 32VBI-ELV is not heatable and, therefore, not suitable for the use in areas where frost is
likely to occur.
Pos: 24 /Beko Tec hnisch e D oku mentation/B estimm ungsgem äße V er wendung/ BEKOM AT/Ausschl uß Anwend ung BM 31/32 nicht fürC O2-Anw endg. +U @ 0\mo d_124282 869624 0_15098 .docx @ 1531 6 @ @ 1
• The iMAT 32VBI-ELV is not suitable for CO2plants.
Pos: 25 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Technical data
iMAT 32VBI-ELV 7
Pos: 26 /B eko T echnisch e Do kumentati on/Übersc hriften/1/Tec hnische D aten @ 0\mod_118432957096 7_15098.doc x @ 1 5131 @ 1 @ 1
5 Technical data
Pos: 27 /Beko Tec hnisch e D oku mentation/Tec hnische Dat en/BE KOMAT/T echn. D aten BM 3xU + UC + GO ST ( o.Leistg.) @5\m od_13588 435789 45_15098. doc x @ 304 77 @ @1
min./max. operating pressure
(see type plate)
0,8...16 bar (12...230 psi)
or
1,2...16 bar (17...230 psi)
min./max. temperature
(see type plate)
+1...+60 °C (+34...+140 °F)
or
+1...+70 °C (+34...+158 °F)
Condensate inflow G ½ internal
max. screw-in depth 13,5 mm (½")
Condensate outflow G ¼ Ø 8 ... 10 mm hose connector
Condensate oil-contaminated + oil-free
Housing aluminium + plastic, glass fibre-reinforced
Weight (empty) 0,8 kg (1.8 lbs)
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1-12, third edition, includ-
ing a later version of the same standard incorporating the same level of testing requirements.
Pos: 28 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Electrical data
8 iMAT 32VBI-ELV
Pos: 29 /B eko T echnisch e Do kumentati on/Übersc hriften/1/Elektr ische D aten @ 0 \mod _118363845 1371_1509 8.docx @ 1 5115 @ 1 @ 1
6 Electrical data
Pos: 30 /B eko T echnisch e Do kumentati on/Elektrisc he Da ten/BEKOM AT/Elektrisch e D aten BM 3 2U/Elektri sche D aten BM 3 2U/33U @ 4\ mod_1357737 405732_1 5098.docx @ 2960 9 @ @ 1
Supply voltage
(see type plate)
95…240 VAC ±10% (50…60 Hz) /100…125 VDC ±10%
or
24…48 VAC ±10% (50…60 Hz) / 18…72 VDC ±10%
Power consumption P = 0,6 ... 3 VA (W)
Recommended
cable-jacket diameter Ø 5,0…10 mm (0,20“…0,39“)
Recommended
wire cross section
Spring-loaded terminal
(voltage supply/relay)
0,75...1,5 mm² (AWG 16...20)
Recommended
wire cross section
Screw terminal
(voltage supply)
0,75...2,5 mm² (AWG 14...20)
Recommended
wire cross section
Spring-loaded terminal
(external test)
0,75...1,5 mm² (AWG 16...20)
Recommended
wire cross section
Screw terminal
(relay/external test)
0,75...1,5 mm² (AWG 16...20)
Recommended
stripping of cable jacket
(voltage supply/relay)
~ 30 mm (~ 1.18")
Recommended
stripping of cable jacket
(external test)
~ 90 mm (~ 3.54")
Recommended
length of the wire end tube
Spring-loaded terminal
8 mm (~ 0.31 inch)
Recommended
length of the wire end tube
Screw terminal
~ 6 mm (~ 0.24 inch)
Connection data of the potential-
free contact
Switch to load*)
AC: max. 250V / 1A
DC: max. 30V / 1A
Connection data of the
potential-free contact
Switch to low signal*)
min. 5 VDC / 10 mA
Connection data of the
external test contact on the unit side 5 VDC; switching current ≥ 0,5 mA
Protection class IP 67
Overvoltage category
(IEC 61010-1) II
VAC = V alternating current
VDC = V direct current
*) The switching of loads means that the properties of the contact are no longer suitable
for the switching of low signals.
Pos: 31 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Dimension drawing
iMAT 32VBI-ELV 9
Pos: 32 /BekoT echnische Doku mentation/Überschriften/ 1Maßzeichnung @ 0\mod _1183638072605_1 5098.docx @ 15109 @ 1@ 1
7 Dimension drawing
Pos: 33 /BekoT echnische Doku mentation/Technische Date n/Masszeichnung @ 0\mod _1184569815280_15 098.docx @ 15135 @ @1
Pos: 34 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Function
10 iMAT 32VBI-ELV
Pos: 35 /Beko Technisch eD okumentation/Üb erschriften/1/Fu nktion @ 0\mod_118 3637775808_150 98.docx @ 15104 @ 1 @ 1
8 Function
Pos: 36 /Beko Technisch eD okumentation/Fu nktion/BEKOMAT /BM Vario-Funktio n @ 0\mod_1185779 978265_15098.doc x @1 5161 @ @1
Via the inlet line (1), the condensate flows into the
iMAT 32VBI-ELV and accumulates in the housing (2).
A capacitive functioning sensor (3) continuously
registers the filling level.
As soon as the condensate has reached a certain
level, a fixed waiting time starts.
During this period, further condensate flows in and
continues filling the iMAT.
iMAT and upstream units must be adjusted to each
other.
After the waiting time has expired, the condensate
may have risen up to the inlet area (1). The solenoid
valve (4) is switched over now and the zone above the
valve membrane is vented.
The valve membrane (5) lifts off from the valve seat,
the overpressure in the housing forces the condensate
into the outlet line (6).
The total amount of accumulated condensate is
discharged.
When the sensor (3) is "free", meaning that the total
amount is discharged, the solenoid valve re-switches
and the valve membrane is re-closed tightly through
the overpressure which builds up above the latter
membrane.
A new cycle starts with the inflow of condensate (1).
Pos: 37 /BekoT echnische Doku mentation/Funktion/BEK OMAT/BM 32U/BM 32U/33U LED -Taster-Funktio n@ 4\ mod_1354691493582_1 5098.docx @ 29067 @ @1

Function
iMAT 32VBI-ELV 11
At the iMAT 32VBI-ELV, two LEDs indicate the
individual operating states.
When applying supply voltage, the iMAT 32VBI-ELV
carries out a self-test.
Both LEDs are lit for approximately 1 second,
subsequently, the device changes over to the "ready-
to-operate" state.
Ready to operate, voltage is applied.
In the event that the condensate discharge is
disturbed, an alarm mode will start which is indicated
by the flashing of the red alarm LED.
Malfunction/alarm
Test of the valve function (manual drainage): press
and hold the button for approximately 2 s.
Test of the alarm function (see below): press and hold
the button for at least 1 min.
Do not use for permanent drainage.
Switching sequence of the valve in the alarm
mode
Alarm mode:
In the event that the iMAT is not empty after one
minute, a trouble indication is released:
• The alarm LED flashes.
• The alarm relay switches over (the signal can be
picked off potential-freely).
• The valve opens every four minutes for 7.5
seconds.
• When the malfunction has been eliminated, the
iMAT will switch back automatically into the normal
mode.
Possible trouble sources include :
• Mistakes during installation
• Dropping below the minimum pressure
• Excessive accumulation of condensate (excess
load)
• Blocked / obstructed outlet line
• Extreme amount of dirt particles
• Frozen pipe work
Trouble indication via a potential-free contact
Pos: 39 /Beko Tec hnisch e D oku mentation/Fu nktion/B EKOMAT /BM 31U/3 2U/BM 31U/ 32U/33U+ Vari o Abl.- Wartu ngs meldg. aktiv ( nicht 32U FMK + IF) W artungsinter vall @ 5\mod _1371731 96481 8_1509 8.docx @ 31047 @ @ 1

Function
12 iMAT 32VBI-ELV
The iMAT 32VBI-ELV releases a maintenance
message for a service that is to be carried out.
Depending on the operating mode, a visual
maintenance message (service) is activated which
signalizes the replacement of the service unit.
The maintenance message is indicated by the flashing
supply voltage-LED "Power".
The maintenance message is released after 1 x 8.760
h or one million switching cycles.
The maintenance signal is released when one of
these two values is reached.
In the event of a power outage or when the energy
supply is deactivated, the status of the timer will be
maintained.
The activities to be carried out regarding maintenance
are described in the chapter entitled "Check and
maintenance".
Prior to the replacement of the service unit, a reset
needs to be carried out. The control unit is released by
actuating the arresting hook. When removed, the
TEST button must be pressed and held for at least
five seconds.
Pos: 40 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Installation
iMAT 32VBI-ELV 13
Pos: 41 /Beko Technisch eD okumentation/Üb erschriften/1/Install ation @ 0\mod_11 83637835418_ 15098.docx @ 15105 @ 1 @ 1
9 Installation
Pos: 42 /Beko Tec hnisch e D oku mentation/Sic herhei t/Gefahr Druc kluft @ 0\mod_1 184148 14385 4_1509 8.docx @ 15121 @ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which are
not secured.
Pos: 43 /BekoT echnische Doku mentation/Sicherheit/Ma ßnahmen Druckluft BM @ 0\mod_1 184148284291_1509 8.docx @ 15123 @ @1
Measures:
• Do not exceed the maximum operating pressure (see type plate).
• Only carry out service measures when the system is pressure less.
•Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant
pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos: 44 /BekoT echnische Doku mentation/Sicherheit/Vorsi chtF ehlfunktion @ 0\mod_121 4378096290_1509 8.docx@ 1 5237 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
iMAT.
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos: 45 /Beko Tec hnisch e D oku mentation/Sic herhei t/Maßnahm en F ehl funktione n BM @ 0 \mod_1 2143784 3402 5_15098.doc x @ 15238 @ @1
r
Measures:
• Condensate drainage which is reliable in performance directly optimizes the compressed-air quality.
• To prevent damage and breakdowns, it is imperative to observe the following:
• Exact compliance with the specifications of use and with the performance parameters of the iMAT,
in connection with the case of application (see "Proper use" section)
• Exact compliance with the installation- and operation instructions in this manual
• Regular maintenance and control of the iMAT in accordance with the instructions in this operating
manual

Installation
14 iMAT 32VBI-ELV
Pos: 46 /Beko Technisch eD okumentation/Sic herheit/Hinweis V orschriften Wer kzeugR einigung Konde nsat Entsorgung @ 0\ mod_1233239666823_ 15098.docx @ 1530 1 @ @ 1
Note
It is imperative to observe all hazard statements and warnings listed here.
Please also observe all regulations and notes regarding industrial safety and fire prevention at the place of
installation.
As a matter of principle, only use suitable and appropriate tools and materials in a proper condition.
Do not use aggressive cleaners and improper devices such as high-pressure cleaners.
Please note that condensates may contain aggressive or harmful components. Therefore, skin contact
should be avoided.
Condensate is subject to mandatory waste disposal. As such, it must be collected in suitable containers, and
disposed of or processed properly.
Pos: 47 /Beko Technisch eD okumentation/In stallation/BEKOMAT /BM 32/33 +U Vario I nstallationshinweise @ 0\ mod_12320955 67742_15098.doc x@ 15 292 @ @ 1
Installation instructions:
• Only the displayed installation position of the iMAT
(3) is permissible. Never install in a horizontal or
any other tilted position.
• Feed pipe (1) and ball valve (2) at least G½.
• No filter or screen in the inlet line.
• Slope in the inlet line >1%.
• Use ball valves (2) only.
• Operating pressure: min. 0,8/1,2 bar (12/17 psig),
max. 16 bar (230 psig). See type plate.
• Short pressure hose (4) fixed on a pressure-
resistant pipe.
• The required minimum pressure increases by
0,1 bar (1,4 psi) per metre gradient in the
discharge pipe (5).
• Discharge pipe (5) rising by max. 5 m (16,4ft).
• Install manifold (6) ¾" with a slope of 1%.
• Introduce the discharge pipe (5) from the top into
the manifold (6).
• Prior to the start-up, always carry out a leak test
and verify the correct engagement of the control
unit.

Installation
iMAT 32VBI-ELV 15
wrong correct
Pressure differences!
Each condensate accumulation point must be drained
separately.
Continuous slope!
Avoid a water pocket when installing the feed pipe
Deflector area!
If drainage is to be carried out directly from the pipe,
deflection of the air flow will be useful.
No venting line!
Do not install a venting line for a iMAT 32VBI-ELV!
Installations, where a venting line is normally required,
are impossible in this case. Another suitable iMAT must
be used.
Pos: 48 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Electrical installation
16 iMAT 32VBI-ELV
Pos: 49 /Beko Technisch eD okumentation/Üb erschriften/1/Ele ktrische Installati on@ 0\ mod_11836385 07355_15098.doc x@ 15 116 @ 1 @ 1
10 Electrical installation
Pos: 50 /Beko Technisch eD okumentation/Sic herheit/Gefa hrNe tzspannung 1 s/w @ 0\m od_11841481869 48_15098.docx @ 151 22@ @ 1
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos: 51 /BekoT echnische Doku mentation/Sicherheit/Ma ßnahmen Netzspannung BM31U/3 2U/33U @ 7\mod_139046719 7804_15098.docx @ 38070 @ @ 1
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
•When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
• The removed control unit has no IP degree of protection.
•All types of electrical works must be carried out by authorized and qualified personnel only.
Pos: 52 /Beko Tec hnisch e D oku mentation/Inst allati on/BEKOMAT /Ele ktrInstallatio n Hi n weise BM32U/ ElektrI nstallatio n Hin weis e BM32U/33U allg. @ 4\ mod_13 577288 84079_15 098.d ocx @ 29541 @ @1
Note:
Power supply connection:
1. Read the permissible supply voltage on the type
plate and make sure this voltage is observed.
2. For the supply voltage, a reliably accessible
separator must be provided close-by (e.g. power
plug or switch), which separates all current-
carrying conductors.
3. At a low voltage supply
(< 50 VAC / < 75 VDC), only use a protective
extra-low-voltage.
4. Carry out installation in accordance with
VDE 0100 / IEC 60364.
5. Observe the terminal assignment.
6. Do not install when the device is energized.
7. Unscrew the screws (1) and remove the upper
part of the cover (2).
8. Unscrew the threaded cable connection (3),
remove the plug (if there is one), and lead the
cable (4) for the power supply through.
9. Connect the cable (4) with terminals X1 (1.1, 1.2)
(5).
10.Install the cables as shown (see also terminal
assignment in the following text).
11.Tighten the threaded cable connection (3) with a
slightly sealing effect.
12.Put on the upper part of the cover (2) and tighten
the screws (1) fingertight.

Electrical installation
iMAT 32VBI-ELV 17
Connection of the potential-free contact and of
the external test:
1. Selection of the suitable cable.
2. Connection to X2 and X3, as shown on the left.
3. The installation steps are the same as for the
power supply connection.
4. If the potential-free contact carries voltage that is
dangerous in the case of contact, a corresponding
separator must also be provided, as described
above.
5. When using the potential-free contacts and the
connection external test, sufficient clearance to
the other parts of the unit, or suitable insulation in
accordance with EN 60664-1 must be ensured.
6. When using a multiwire, common line for the
connection of the potential-free contact and the
external test, this line must be suitable for the
highest occurring voltage and the intended
temperature range with regard to its nominal
ratings.
Pos: 53 /Beko Tec hnisch e D oku mentation/Inst allati on/BEKOMAT /Kle mmen belegung BM 32U/ Klemm enbelegu ng BM 3 2U/33U @ 4\m od_1 35469295 2721_1 5098.doc x @ 2 9135 @ @1
Terminal assignment supply voltage (operating voltage)
X 1 X 2 X 3 Power supply
• X 1.1 L/+
• X 1.2 N/-
L = Outer conductor
N = Neutral conductor
L/+
N/-
NO
CO
NC
IN1
GND
phase
neutral
normally open
common
normally closed
external test (IN1)
GND
1.1
1.2
2.1
2.2
2.3
3.1
3.2
Terminal assignment low voltage (operating voltage)
X 1 X 2 X 3 Power supply
• X 1.1 L/+
• X 1.2 N/-
L/+
N/-
NO
CO
NC
IN1
GND
power
power
normally open
common
normally closed
external test (IN1)
GND
1.1
1.2
2.1
2.2
2.3
3.1
3.2

Electrical installation
18 iMAT 32VBI-ELV
Terminal assignment of the potential-free contact and of the external test
X 1 X 2 X 3 Fault indication/potential-free contact:
• X 2.1 n.o.
• X 2.2 com.
• X 2.3 n.c.
n.c. - com. closed in the event of malfunction or power failure
n.o. - com. closed during normal operation
(closed current principle)
The contacts X2.1 - 2.3 are potential-free.
External test / remote control:
• X 3.1 external test (IN1)
• X 3.2 GND
Contacts connected = test active = discharge
Contacts open = test inactive
The contacts X 3.1 -3.2 are not potential-free.
L/+
N/-
NO
CO
NC
IN1
GND
power
power
normally open
common
normally closed
external test (IN1)
GND
1.1
1.2
2.1
2.2
2.3
3.1
3.2
Note:
At a low-voltage supply (< 50 VAC / < 75 VDC), only use a protective extra-low-voltage.
Tighten the threaded cable connection with a slightly sealing effect.
Pos: 54 /BekoT echnische Doku mentation/Installation/B EKOMAT/E-Sche ma@ 0\ mod_1233758178 163_15098.docx @ 15305 @ @ 1
Electric diagram
Pos: 55 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Control and maintenance
iMAT 32VBI-ELV 19
Pos: 56 /Beko Technisch eD okumentation/Üb erschriften/1/K ontrolle und Wartung @ 0\m od_11836378853 71_15098.doc x@ 151 06 @ 1 @ 1
11 Control and maintenance
Pos: 57 /Beko Tec hnisch e D oku mentation/Sic herhei t/Gefahr Druc kluft @ 0\mod_1 184148 14385 4_1509 8.docx @ 15121 @ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which are
not secured.
Pos: 58 /BekoT echnische Doku mentation/Sicherheit/Ma ßnahmen Druckluft BM @ 0\mod_1 184148284291_1509 8.docx @ 15123 @ @1
Measures:
• Do not exceed the maximum operating pressure (see type plate).
• Only carry out service measures when the system is pressure less.
•Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant
pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos: 59 /Beko Technisch eD okumentation/Sic herheit/Gefa hrNe tzspannung 1 s/w @ 0\m od_11841481869 48_15098.docx @ 151 22@ @ 1
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos: 60 /BekoT echnische Doku mentation/Sicherheit/Ma ßnahmen Netzspannung BM31U/3 2U/33U @ 7\mod_139046719 7804_15098.docx @ 38070 @ @ 1
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
•When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
• The removed control unit has no IP degree of protection.
•All types of electrical works must be carried out by authorized and qualified personnel only.
Pos: 61 /BekoT echnische Doku mentation/Sicherheit/Vorsi chtF ehlfunktion @ 0\mod_121 4378096290_1509 8.docx@ 1 5237 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
iMAT.
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos: 62 /Beko Tec hnisch e D oku mentation/Sic herhei t/Maßnahm en F ehl funktione n BM @ 0 \mod_1 2143784 3402 5_15098.doc x @ 15238 @ @1
r
Measures:
• Condensate drainage which is reliable in performance directly optimizes the compressed-air quality.
• To prevent damage and breakdowns, it is imperative to observe the following:
• Exact compliance with the specifications of use and with the performance parameters of the iMAT,
in connection with the case of application (see "Proper use" section)
• Exact compliance with the installation- and operation instructions in this manual
• Regular maintenance and control of the iMAT in accordance with the instructions in this operating
manual
Pos: 63 /---- Seitenumbruch ---- @ 0\mod_1 157028099015_0.d ocx@ 153 20@ @ 1

Control and maintenance
20 iMAT 32VBI-ELV
Pos: 64 /Beko Technisch eD okumentation/Sic herheit/Hinweis V orschriften Wer kzeugR einigung Konde nsat Entsorgung @ 0\ mod_1233239666823_ 15098.docx @ 1530 1 @ @ 1
Note
It is imperative to observe all hazard statements and warnings listed here.
Please also observe all regulations and notes regarding industrial safety and fire prevention at the place of
installation.
As a matter of principle, only use suitable and appropriate tools and materials in a proper condition.
Do not use aggressive cleaners and improper devices such as high-pressure cleaners.
Please note that condensates may contain aggressive or harmful components. Therefore, skin contact
should be avoided.
Condensate is subject to mandatory waste disposal. As such, it must be collected in suitable containers, and
disposed of or processed properly.
Pos: 65 /B eko T echnisch e Do kumentati on/Wartung/ BEKOMAT/ Wartung BM 32U Vari o (nich t IF) built-i n 1 x8760h @ 6\ mod_1 37528434 3786_15098.d ocx @ 3 2887 @ @ 1
Maintenance recommendation:
After 8,760 operating hours or one million switching
cycles, a maintenance message is released.
The green power LED flashes. Afterwards, or at the
latest after one year (8,760 operating hours), the
service unit (5) needs to be replaced.
1. Prior to the replacement of the service unit, a reset
needs to be carried out. The control unit is
released by actuating the arresting hook. When
removed, the TEST button below the LED must be
pressed and held for at least five seconds.
Table of contents
Other ICP Heat Pump manuals

ICP
ICP FEM4P Series User manual

ICP
ICP CHS180 Dimensions and installation guide

ICP
ICP HMC009KD User manual

ICP
ICP HC4H3 User manual

ICP
ICP PHD548 User manual

ICP
ICP PYPA Series User manual

ICP
ICP HMC036KDT1 User manual

ICP
ICP PHX4 User manual

ICP
ICP PHF348000K00A1 Quick start guide

ICP
ICP C4H318GKD200 Installation instructions

ICP
ICP N4H318AKE100 Installation instructions

ICP
ICP N4H3 User manual

ICP
ICP WPH324 User manual

ICP
ICP PHJ3 Instruction Manual

ICP
ICP PHF3 User manual

ICP
ICP PH55 Series User manual

ICP
ICP PDX424040K00A1 User manual

ICP
ICP PHAD60N1K1 User manual

ICP
ICP C4H418GKD200 Installation instructions

ICP
ICP PHF Series User manual