Model Power
Supply
Voltage
Power
(Watts)
Range Condensation
Removal
(24 hrs)
Size
(inches)
N.W.
(lbs)
701600 115V/60Hz-
1 Phase
12.31 Amps/
1350W 41° F- 95° F 180 pints
(86° F, 80% RH) 22.5” x 23” x 40” 135 lbs
TECHNICAL PARAMETERS
Code Meaning
E1 Temperature sensor failure
E2 Coil sensor failure
ERROR CODES
TROUBLESHOOTING TIPS
HUMIDITY CONTROL: When the humidity reaches
the set point, the machine will stop automatically.
It will automatically start the machine when the
humidity in your space rises above the set point.
The humidity range is 30-90%; The machine will
stop +5% of set humidity and restart below -5%
of set humidity.
WATER INLET: When the water level in the water
tank decreases, the float switch will activate and the
water tank will refill automatically and stop filling
when the water level rises to the maximum height.
LOW WATER LEVEL WARNING: When the
system detects the water level is lower than the
warning level, the machine will stop automatically.
The system will warn if water is not refilled in 10
minutes.
FAN DELAY PROTECTION: When the
humidifier is turned off the fan will continue to run
for another 30 seconds to drain all the residual
water and cool the unit.
SYSTEM FUNCTION
Failure Cause Analysis Method
Dehumidifier doesn't
work
1. Power cut
2. Power switch is not energized
3. Power cord is not connected
4. Fuse is melted
1. Recover the power
2. Energize the power
3. Connect the power cord
4. Replace the fuse
Dehumidification is
not ideal
1. Dust accumulated in air purification filter mesh
2. Object blocking air inlet and outlet
3. The door or window is open
4. Refrigerant is leaking
1. Clear the filter mesh
2. Remove the blocking object
3. Close the door and window
4. Contact distributor or manufacturer for repair
Water leak 1. The machine is inclined
2. Water pipe is blocked
1. Level the machine
2. Remove the blocking object
Abnormal noise 1. The machine is not placed solidly
2. The filter mesh is blocked
1. Place the machine firmly.
2. Clear the filter mesh
If the above troubleshooting does not fix your issues and repair, please contact Ideal-Air™
technical support. Do not disassemble without authorization.