manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. IDEAL
  6. •
  7. Boiler
  8. •
  9. IDEAL Concord CXA 40 User manual

IDEAL Concord CXA 40 User manual

This manual suits for next models

1

Other IDEAL Boiler manuals

IDEAL MINI C24 User manual

IDEAL

IDEAL MINI C24 User manual

IDEAL COMBI ESP 24 User manual

IDEAL

IDEAL COMBI ESP 24 User manual

IDEAL LOGIC Combi E User manual

IDEAL

IDEAL LOGIC Combi E User manual

IDEAL INSTINCT 24 User manual

IDEAL

IDEAL INSTINCT 24 User manual

IDEAL he15 User manual

IDEAL

IDEAL he15 User manual

IDEAL Exalt FSB 110 User guide

IDEAL

IDEAL Exalt FSB 110 User guide

IDEAL LOGIC CODE COMBI ESP1 26 User manual

IDEAL

IDEAL LOGIC CODE COMBI ESP1 26 User manual

IDEAL imax plus F80 User manual

IDEAL

IDEAL imax plus F80 User manual

IDEAL Mexico Slimline CF3/40 User manual

IDEAL

IDEAL Mexico Slimline CF3/40 User manual

IDEAL classic HE15P User manual

IDEAL

IDEAL classic HE15P User manual

IDEAL LOGIC SYSTEM s15 User manual

IDEAL

IDEAL LOGIC SYSTEM s15 User manual

IDEAL he15 User manual

IDEAL

IDEAL he15 User manual

IDEAL istor HE260 User manual

IDEAL

IDEAL istor HE260 User manual

IDEAL ES24 User manual

IDEAL

IDEAL ES24 User manual

IDEAL HE36 User manual

IDEAL

IDEAL HE36 User manual

IDEAL Vogue Combi c26 User manual

IDEAL

IDEAL Vogue Combi c26 User manual

IDEAL Logic HEAT 12 User manual

IDEAL

IDEAL Logic HEAT 12 User manual

IDEAL HE9 User manual

IDEAL

IDEAL HE9 User manual

IDEAL EVOMAX 2 Series User manual

IDEAL

IDEAL EVOMAX 2 Series User manual

IDEAL he15 User manual

IDEAL

IDEAL he15 User manual

IDEAL Henrad SEC 80FF User guide

IDEAL

IDEAL Henrad SEC 80FF User guide

IDEAL Vogue S15 User manual

IDEAL

IDEAL Vogue S15 User manual

IDEAL EXALT COMBI User manual

IDEAL

IDEAL EXALT COMBI User manual

IDEAL Esprit eco 30 User manual

IDEAL

IDEAL Esprit eco 30 User manual

Popular Boiler manuals by other brands

UTICA BOILERS BC3D Installation, operation & maintenance manual

UTICA BOILERS

UTICA BOILERS BC3D Installation, operation & maintenance manual

Lochinvar SOLUTION 260000 Installation & service manual

Lochinvar

Lochinvar SOLUTION 260000 Installation & service manual

Weil-McLain EG 6 Series manual

Weil-McLain

Weil-McLain EG 6 Series manual

RBI LCD Series Installation & operation manual

RBI

RBI LCD Series Installation & operation manual

Baxi MainEco Combi 28 Installation and service manual

Baxi

Baxi MainEco Combi 28 Installation and service manual

Unical ALKON R 24 Installation and Servicing Manual

Unical

Unical ALKON R 24 Installation and Servicing Manual

Automatic Heating Gasogen Installation and Servicing Manual

Automatic Heating

Automatic Heating Gasogen Installation and Servicing Manual

Viessmann VITORADIAL 300-T Type VR3 Service instructions for contractors

Viessmann

Viessmann VITORADIAL 300-T Type VR3 Service instructions for contractors

Alpha GasSaver GS-1 Installation and servicing instructions

Alpha

Alpha GasSaver GS-1 Installation and servicing instructions

Baxi ROCA LAURA PLUS 28/28 Operating, cleaning and maintenance instructions for the user

Baxi

Baxi ROCA LAURA PLUS 28/28 Operating, cleaning and maintenance instructions for the user

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Vaillant

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Kärcher HWE 4000 Gas manual

Kärcher

Kärcher HWE 4000 Gas manual

Radijator BIO max 23.1 instruction manual

Radijator

Radijator BIO max 23.1 instruction manual

Granby BKC Installation, operation and maintenance manual

Granby

Granby BKC Installation, operation and maintenance manual

Brunner BSV 20 Instructions for use

Brunner

Brunner BSV 20 Instructions for use

Potterton 50e Installation and Servicing Manual

Potterton

Potterton 50e Installation and Servicing Manual

UTICA BOILERS TriFire Assembly instructions

UTICA BOILERS

UTICA BOILERS TriFire Assembly instructions

ECR International UB90-125 Installation, operation & maintenance manual

ECR International

ECR International UB90-125 Installation, operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

2Concord CXA 40/H-120/H - User's Guide
ALL MODELS
THE GAS SAFETY (INSTALLATION & USE)
REGULATIONS OR RULES IN FORCE impose
certain statutory obligations on gas users. This
appliance must be installed by a CORGI
registered installer.
Knob setting Approx. flow temp oC Approx. flow temp oF
1 60 140
2 64 147
3 69 156
4 73 163
5 77 171
6 82 180
WARNING.
This appliance MUST be efficiently earthed.
1. It is ESSENTIAL that the instructions in this booklet
are strictly followed, for safe, economical operation of
the boiler.
2. Do not obstruct ventilation ducts, grilles or openings in
the boiler room, or the passage of combustion and
ventilation air to the boiler.
3. Do not store objects around or on the boiler, and keep
access clear at all times.
4. Switch off and disconnect the electricity supply before
carrying out maintenance work.
5. Do not turn off the boiler if it is to be left unattended in
frosty weather.
MAINTENANCE
The appliance should be serviced at least once a
year by a CORGI registered installer.
CLEANING
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains use a damp
cloth and mild detergent.
DO NOT use abrasive cleaning materials.
CAUTION.
To avoid the possibility of injury during the use or cleaning of this
appliance care should be taken when handling edges of sheet steel components.
CONCORD CXA 40/H - 80/H models
1
65
7
2
4
LEGEND
1. Thermostat knob.
2. Mains gas inlet cock.
3. Overheat thermostat
button.
4. Lockout light.
5. Lockout reset button.
6. Burner on light.
7. Overheat light
2
3
Con 5241
3
Concord CXA 40/H-120/H - User's Guide
CONCORD CXA 90/H - 120/H models
2
TO LIGHT THE BOILER
1. Check that the boiler thermostat knob (1) on the control box
is OFF.
2. Ensure that the mains gas inlet cock (2) is open (groove in
the square head in line with the gas pipe).
3. Press in the overheat thermostat button (3).
4. Ensure all system controls (time switch, system controls
etc.) are calling for heat.
5. Turn the boiler thermostat knob (1) to position 6.
6. If the boiler does not light at the end of the ignition period
the Lockout light (4) on the control box will be illuminated.
Press in and release the Lockout reset button (5). The
controls will reset and after a period of time will attempt to
relight.
7. Once the pilot has lit the controls open the main gas valves
and the main burners will light and the Burner On light (6)
will be illuminated.
8. Set all system controls to the required settings.
9. Set the boiler thermostat knob (1) to the required setting.
LEGEND
1. Thermostat knob.
2. Mains gas inlet cock.
3. Overheat thermostat
button.
4. Lockout light.
5. Lockout reset button.
6. Burner on light.
7. Overheat light
CONTROL PANEL LIGHTS
1. The Boiler On light (6) is illuminated while the boiler is firing.
2. If the Overheat light (7) is lit, pull off the casing lower front
panel and press in the overheat reset button (3). Replace
the lower front panel and follow the boiler lighting instructions
above. If the overheat condition persists consult a CORGI
registered installer.
3. If the Lockout light (4) is lit press in the Lockout reset button
(5).
If the lockout condition persists consult a CORGI registered
installer.
TO SHUT DOWN THE BOILER
For short periods
Turn the boiler off at the time clock or system controls. Wait 6
min. and then turn the boiler control thermostat knob (1) to
OFF. Note the frost warning below.
For long periods
Turn the boiler off at the time clock or system controls. Wait for
6 min. and then turn the boiler control thermostat knob (1) to
OFF. Turn off the inlet gas cock (groove in the square head
across the line of the gas pipe). Note the frost warning below.
TO RELIGHT THE BOILER
After short periods
Switch on the time switch or system controls and turn boiler
thermostat knob (1) to the required setting. The boiler will light
providing the external controls are calling for heat.
After long periods
Follow the lighting instructions above. Refill the system if it has
been drained.
FROST WARNING
If frost is likely, leave the boiler thermostat at position 6 and
do not turn off the gas cock. This will enable the built-in frost
thermostat to protect the boiler. Note that this may not protect
remote parts of the system, in which case a separate frost
thermostat should be fitted or the system drained and the
boiler shut down, as for "Long Periods".
3
Con 1971
2
1
65
4
7
Ideal Boilers
,
P.O. Box 103, National Ave, Kingston upon Hull,
HU5 4JN. Telephone: 01482 492 251 Fax: 01482 448 858.
Registration No. London 322 137.
January 2002 UIN 157296 A02
Caradon Ideal Limited pursues a policy of continuing
improvement in the design and performance of its products. The
right is therefore reserved to vary specification without notice.
I
deal Installer/Technical Helpline: 01482 498 376
www.idealboilers.com