IFM DV13 0 Series User manual

Operating instructions
3-segment signal light
DV13x0
DV23x0
11404095 / 0006 / 2021
GB

DV13x0 DV23x0 3-segment signal light
2
Contents
1 Preliminary note ............................................................. 3
1.1 Symbols used.......................................................... 3
2 Safety instructions............................................................ 4
3 Intended use................................................................ 5
4 Function ................................................................... 6
4.1 IO-Link ............................................................... 6
5 Installation.................................................................. 7
6 Electrical connection.......................................................... 8
6.1 Pin assignment......................................................... 8
6.1.1 IO-Link device (DV23x0).............................................. 8
6.1.2 Standard device (DV13x0) ............................................ 8
7 Operating and display elements................................................. 9
8 Operation .................................................................. 10
8.1 Operation of the IO-Link version............................................ 10
8.1.1 General........................................................... 10
8.1.2 On/Off mode....................................................... 10
8.1.3 RGB mode ........................................................ 10
8.2 Operation of the standard version........................................... 11
8.3 Demo mode ........................................................... 11
9 Parameter setting............................................................ 12
9.1 IO-Link version......................................................... 12
9.2 Standard version........................................................ 12
9.2.1 Parameter structure ................................................. 12
10 Maintenance, repair and disposal................................................ 14

3-segment signal light DV13x0 DV23x0
3
1 Preliminary note
You will find instructions, technical data, approvals and further information using the QR code on the
unit / packaging or at www.ifm.com.
1.1 Symbols used
Requirement
Instructions
Reaction, result
[...] Designation of keys, buttons or indications
Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note
GB

DV13x0 DV23x0 3-segment signal light
4
2 Safety instructions
• The unit described is a subcomponent for integration into a system.
– The system architect is responsible for the safety of the system.
– The system architect undertakes to perform a risk assessment and to create documentation in
accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.
• Read this document before setting up the product and keep it during the entire service life.
• The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.
• Only use the product for its intended purpose (Ò Intended use).
• If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.
• The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.
• Installation, electrical connection, set-up, programming, configuration, operation and maintenance
of the product must be carried out by personnel qualified and authorised for the respective activity.
• Protect units and cables against damage.
• Replace damaged units, otherwise the technical data and safety will be impaired.

3-segment signal light DV13x0 DV23x0
5
3 Intended use
The unit is used for the visual display of machine conditions. The versions DVx310 and DVx330
additionally have a buzzer for acoustic signalling.
The LED segments and the audible warning device can be switched on and off individually.
The unit is not suited for environments with particular requirements on mechanical stability (e.g.
shock/vibration).
The unit is intended for indoor use only.
uObserve the operating conditions (Ò Technical data at www.ifm.com).
The unit is not approved for safety-related tasks in the field of operator protection.
GB

DV13x0 DV23x0 3-segment signal light
6
4 Function
The standard units are DV13xx. The DV23xx units are IO-Link devices.
The IO-Link version can be triggered and configured via the standard IO-Link interface. With the
standard version the individual LED segments can be switched individually via digital inputs.
Parameters are set via a parameter setting button or via an additional IO-Link interface.
4.1 IO-Link
This unit has an IO-Link communication interface which enables direct access to process and
diagnostic data. In addition it is possible to set the parameters of the unit while it is in operation.
Operation of the unit via the IO-Link interface requires an IO-Link master.
With a PC, suitable IO-Link software and an IO-Link adapter cable, communication is possible while
the system is not in operation.
The IODDs necessary for the configuration of the unit, detailed information about process data
structure, diagnostic information, parameter addresses and the necessary information about the
required IO-Link hardware and software can be found at www.ifm.com.

3-segment signal light DV13x0 DV23x0
7
5 Installation
uDisconnect the power of the machine before installation.
uFor installation choose a flat mounting surface.
1
18
40
M4
Fig.1: Fixture (view from bottom)
1: Front side
uAttach the fixture for the unit to the mounting surface using the supplied M4 nuts. Tightening torque
1.8 Nm.
uOnly with the models DVx300 and DVx310:
For mounting on a horizontal surface attach the base to the fixture (overlapping marks on base and
fixture) and turn clockwise by approx. 10 ° to fix it. For mounting on a vertical surface loosen the
screw in the base, turn the upper part of the base by 180 ° and tighten the screw again. Attach the
base to the fixture (overlapping marks on base and fixture) and turn clockwise by approx. 10 ° to fix
it.
uInsert the cable through the fixture and, if necessary, the base and connect the socket with the M12
connector in the signal lamp. Tightening torque max. 1 Nm. (Observe the maximum tightening
torque of the connection cable.)
uAttach the signal lamp to the fixture or the base (overlapping marks) and turn clockwise by approx.
10 ° to fix it.
Integrated seals at the bottom of the fixture and in the base as well as O-rings at the fixture and
base prevent ingress of moisture.
Information about available accessories at www.ifm.com
GB

DV13x0 DV23x0 3-segment signal light
8
6 Electrical connection
The device must be connected by a qualified electrician.
Observe the national and international regulations for the installation of electrical equipment.
Voltage supply according to EN50178, SELV, PELV.
The IO-Link port must be connected according to the IO-Link specification.
uDisconnect power.
uConnect the cable with the M12 connector of the unit.
Tightening torque max. 0.4 Nm.
Observe the maximum tightening torque of the connection cable.
6.1 Pin assignment
6.1.1 IO-Link device (DV23x0)
M12 plug IO-Link, 4-pole (4 x 0.34 mm² / AWG 22)
43
2 1
1: L+
2: not used
3: L-
4: IO-Link
6.1.2 Standard device (DV13x0)
M12 plug, 8-pole (8 x 0.25 mm² / AWG 24)
6
2 1
4
5
7
3
8
1: not used
2: Buzzer (DV1310 and DV1330)
3: LED segment 3
4: LED segment 2
5: Voltage supply
6: LED segment 1
7: not used
8: IO-Link
The input polarity is selectable.
uConnect pin 5 to +24 V DC to trigger the inputs with a NPN transistor.
uConnect pin 5 to GND to trigger the inputs with an PNP transistor.
When triggered via IO-Link (pin 8) without E12572 connection cable:
uConnect pin 5 to +24 V DC.
uConnect pin 3 to GND.

3-segment signal light DV13x0 DV23x0
9
7 Operating and display elements
4
6
2
3
4
5
1
1: Parameter setting button (only DV13x0)
2: LED segment 1 with 4 RGB LEDs
3: LED segment 2 with 4 RGB LEDs
4: LED segment 3 with 4 RGB LEDs
5: Buzzer (only DVx310 and DVx330)
6: Feedback LED (only DV13x0)
GB

DV13x0 DV23x0 3-segment signal light
10
8 Operation
8.1 Operation of the IO-Link version
8.1.1 General
Connect the unit to an IO-Link master (A port) using a 4-pole connection cable. The controller
switches the individual LED segments on and off in the configured colours according to the set
parameters.
Via the parameter [Operating mode] the following modes can be set:
• On/Off mode
• RGB mode
8.1.2 On/Off mode
While the unit is operating, the controller switches the LED segment and the buzzer (if present) on and
off (PDout, cyclical data communication). Signalling corresponds to the pre-defined parameters for the
individual LED segments and the buzzer.
Via the acyclic parameter setting the following properties can be set for every LED segment:
• Colour (red, green, orange, blue, purple, turquoise, white, yellow, off)
• Frequency (permanently on, low flash rate slow/medium/fast, high flash rate slow/medium/fast)
• Brightness (100 %, 75 %, 50 %, 25 %)
For the models with an acoustic signal device the audibility of the buzzer can be set.
76543210PDout
Seg. 3 Seg. 2 Seg. 1 Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Buzzer sound (buzzer style 1...8) Buzzer Byte 5
8.1.3 RGB mode
While the unit is operating, the controller switches the LED segment and the buzzer (if present) on and
off and determines the corresponding properties (PDout, cyclical data communication).
In this operating mode 8 different acoustic signals are available for the buzzer.
76543210PDout
Segment 1 LED properties Seg. 1 yel-
low
Seg. 1 red Seg. 1
green
Seg. 1 blue Byte 0
Segment 2 LED properties Seg. 2 yel-
low
Seg. 2 red Seg. 2
green
Seg. 2 blue Byte 1
Segment 3 LED properties Seg. 3 yel-
low
Seg. 3 red Seg. 3
green
Seg. 3 blue Byte 2
Buzzer sound (buzzer style 1...8) Buzzer Byte 3
The properties of the LED segments are defined as follows:

3-segment signal light DV13x0 DV23x0
11
Byte 0
Bit 3
Byte 0
Bit 2
Byte 0
Bit 1
Byte 0
Bit 0 Colour
0 0 0 0 off
0 1 0 0 red
0 0 1 0 green
0 1 1 0 orange
0 0 0 1 blue
0 1 0 1 purple
0 0 1 1 turquoise
0 1 1 1 white
1 0 0 0 yellow
Byte 0
Bit 6
Byte 0
Bit 5
Byte 0
Bit 4 Frequency
0 0 0 permanently on
0 0 1 low flash rate slow
0 1 0 low flash rate medium
0 1 1 low flash rate fast
1 0 0 high flash rate slow
1 0 1 high flash rate medium
1 1 0 high flash rate fast
8.2 Operation of the standard version
The unit is connected to the digital outputs of the controller via an 8-pole cable (see accessories at
www.ifm.com). The HTTL inputs of the signal lamp are triggered with 24 V DC. According to the set
parameters the LED segments are on and the buzzer sounds (if present).
The signal inputs can be triggered either in PNP or in NPN technology (Ò Electrical connection > Pin
configuration > Standard unit).
With the parameter setting button the following properties can be set for every LED segment:
• Colour (red, green, orange, blue, purple, turquoise, white, yellow, off)
• Frequency (permanently on, low flash rate slow/medium/fast, high flash rate slow/medium/fast)
• Brightness (100 %, 75 %, 50 %, 25 %)
Parameter setting via the IO-Link interface (pin 8 of the M12 connector) is also possible.
After parameter setting the unit goes to the Run mode.
8.3 Demo mode
In demo mode, the unit demonstrates the different
• Colours
• Buzzer sounds (buzzer styles, provided the unit features a buzzer)
Set the parameter [Demo mode] in the IO-Link parameter setting tool. For SIO and IO-Link mode, the
demo is available in 3 different speeds, respectively.
GB

DV13x0 DV23x0 3-segment signal light
12
9 Parameter setting
9.1 IO-Link version
The parameters of the device can be set using an IO-Link parameter setting tool IO-Link (Ò/6).
IO Device Description (IODD) with all parameters and process data of the unit can be found at
documentation.ifm.com.
9.2 Standard version
uTurn the transparent protective cover anticlockwise by approx. 10 ° and remove it.
uBriefly press the parameter setting button at the head of the unit (< 5 s).
wThe feedback LED is green on.
The unit is in the parameter setting mode.
uBriefly press the parameter setting button (< 5 s) to go to the next parameter.
uPress the parameter setting button for a longer time (> 5 s) to set the selected parameter.
wThe feedback LED flashes green.
The unit indicates the current settings of the LED segment to be configured.
uBriefly press the parameter setting button (< 5 s) to change the value for the selected parameter.
Repeat this step until the requested setting is selected.
wThe unit indicates the current settings of the LED segment to be configured.
uPress the parameter setting button for a longer time (> 5 s) to save the selected value for this
parameter.
wThe feedback LED flashes green.
The unit saves the value and goes to the next parameter.
wAfter configuration of all LED segments the unit displays the current settings of all LED
segments.
uBriefly press the parameter setting button (< 5 s) to finish the parameter setting mode.
wThe feedback LED goes out. The unit is in the Run mode.
If the parameter setting button is not pressed for longer than 30 seconds, the unit saves the last
changes and goes to the Run mode.
9.2.1 Parameter structure
LED
seg. Parameter Value
1 Colour red green orange blue purple tur-
quoise
white yellow off
Frequency on low flash
rate
slow
low flash
rate
medium
low flash
rate
fast
high
flash
rate
slow
high
flash
rate
medium
high
flash
rate
fast
Brightness 100 % 75 % 50 % 25 %
2 Colour red green orange blue purple tur-
quoise
white yellow off
Frequency on low flash
rate
slow
low flash
rate
medium
low flash
rate
fast
high
flash
rate
slow
high
flash
rate
medium
high
flash
rate
fast

3-segment signal light DV13x0 DV23x0
13
LED
seg. Parameter Value
2 Brightness 100 % 75 % 50 % 25 %
3 Colour red green orange blue purple tur-
quoise
white yellow off
Frequency on low flash
rate
slow
low flash
rate
medium
low flash
rate
fast
high
flash
rate
slow
high
flash
rate
medium
high
flash
rate
fast
Brightness 100 % 75 % 50 % 25 %
GB

DV13x0 DV23x0 3-segment signal light
14
10 Maintenance, repair and disposal
Cleaning the unit:
uDisconnect the unit from the voltage supply.
uClean the unit from dirt using a soft, chemically untreated and dry micro-fibre cloth.
The operation of the unit is maintenance-free.
Only the manufacturer is allowed to repair the unit.
uAfter use dispose of the device in an environmentally friendly way in accordance with the
applicable national regulations.
This manual suits for next models
1
Table of contents
Other IFM Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

DOTLUX
DOTLUX LIGHTSHOWERsmart 4897-050090 user manual

Velleman
Velleman MML6R user manual

Elation
Elation Design LED 36 Tri-Brick Technical specifications

Lightolier
Lightolier Pendalyte 40472U specification

Abriblue
Abriblue Nextpool Slat cover installation manual

Tracon Electric
Tracon Electric RGBW CORNER user manual