IGV Care User manual

1
PACKAGE CONTENTS
No. 1 CARe unit
No. 1 pre-installed HEPA air lter
No. 2 adjustable valves for venlaon
No. 2 valve sleeves
No. 1 exible spiral pipe (2 metres)
No. 1 UVGI germicidal LED spot
No. 1 moon sensor
No. 10 adhesive informaon plates
documentaon
GENERAL WARNINGS
ASSEMBLY INSTRUCTIONS
Professional system for the active
sanitization of the lift car

2
8
8
1
3
4
5
6 7
2
9
ARRANGEMENT
• Provide 2 Ø 80 mm holes at the ends of the ceiling for the installa on of the ven la on valves.
Tip: The 2 holes should be drilled as far as possible from each other to maximize the effi ciency of the ven la on system.
• Provide 1 Ø 60 mm hole in the centre of the ceiling for the installa on of the UVGI spotlight.
Tip: Drill the hole as centrally as possible, for a more uniform diff usion of the UV-C rays.
• Provide 1 hole near one of the li car corners, where the car walls join the ceiling, to be used for the mo on sensor cable.
INSTALLATION
• Posi on the CARe unit (1) on the car roof, inser ng the lower connec on (2) of the unit into one of the 2 Ø 80 mm holes drilled in the
ceiling and plug the ow valve (3) directly into it. Similarly, insert the return valve (6) into the second Ø 80 mm hole.
• Insert the exible pipe (4) into the top connec on (5) of the unit and connect it to the return valve (6) previously inserted into the
second Ø 80 mm hole in the ceiling using the sleeve included in the supply.
• Fix the 2 ends of the exible pipe (4) using the provided metal collars.
• Insert the UVGI spotlight into the hole (7) in the centre of the ceiling using the supplied snap-on clips (8).
• Install the mo on sensor (9) on the wall or, alterna vely, on the ceiling using one of the two brackets included in the supply.
Tip: Install the sensor in the most angled posi on to op mise the volumetric coverage.
CONNECTION
• Connect the UVGI spotlight to the UVC cable of the unit.
• Connect the mo on sensor to the RIC cable of the unit.
• Power the CARe unit through the ALIM cable ( xed light - mobile light of the car) of the unit.
Tip: Check the a ached wiring diagram for connec ons.
WARNINGS
• Place an adhesive informa on plate next to each landing access.
ASSEMBLY INSTRUCTIONS

3
OR
GN
RD
BU
VT
PK
WH
GY
BN
BK
YE
-
LN
+
ALMTAMPER
ALM+-
A1
A2
-RL
230Vac
12 1114 /1.13
22
2124 /1.19
TNL
A2
A1
-TIM
TIPO RE
20'
12
1114 /1.19
-CDTR
-UVC
-CDTR
A2
A1
-SENS
TIPO RE
30"
12 1114 /1.1912
11
14
-SENS
12
11
14
-TIM
22
21
24
-RL
12
11
14
-RL
-LCM-LCF
3x1
-ALIM
3x0,5
-RIC
2x0,5
-UVC
3x0,5
-RIC
+QE
BN GN WH
BN GN WH WH BN
BN
BN
BN
BK RD
RD
GY BU
BU
BU
BN GYBK
BN
BN
+CAB
+CARE
LN
CAR MOBILE LIGHT
CAR FIXED LIGHT
CONTROL PANEL
CAR DETECTOR
POWER UNIT
FAN
RED
PURPLE
PINK
WHITE
GREY
BROWN
BLACK
COLOURCODE
WIRES DESCRIPTION
YELLOW
ORANGE
GREEN
BLUE
WIRING

4
GENERAL WARNINGS
Please read this document carefully before installing and using the system.
The informaon and instrucons contained herein are essenal for proper
installaon and proper use of the device.
• Intervenons by unauthorized personnel, or not in compliance with the
instrucons given in this manual, hold the manufacturer (or distributor) not
responsible for any consequence that may arise.
• Intervenons by the user on the device are absolutely forbidden. The system
is designed and built with mechanical and electrical safety devices to protect
the operator and the user from any physical damage.
• It is the responsibility of the installer to conrm that the informaon and
warnings for the use of the li have been made available to the user.
• Despite these safees, the operator and user must be aware of any potenal
risk that may exist while operang the device.
• Any modicaon to the system must be considered under full responsibility
of the installer.
• The system must be subjected to roune maintenance.
The CARe device consists of two components separately performing the funcons
of sanizing the li car air and disinfecng the surfaces inside the car.
AIR SANITIZATION
Air sanizaon is achieved by means of an air lter/fan that allows air
exchange through an absolute HEPA lter. This air lter is built according to
good engineering pracce, in compliance with the applicable EC Direcves
and its intended use is to carry out the air exchange in the spaces where it is
installed. Follow these instrucons carefully to ensure durability, electrical and
mechanical reliability. Keep this document in a safe place.
• Aer unpacking, check the integrity of the device.
• Before connecng the device, conrm that the plate informaon meet those
of the mains supply.
• This device must only be used for the purpose for which it was expressly
designed. The manufacturer cannot be held liable for any damage resulng
from improper, incorrect and unreasonable use.
• Do not use the product in the presence of corrosive or explosive vapours.
• Before carrying out any cleaning or maintenance operaons, disconnect the
device from the power supply. The maintenance and cleaning operaons
requiring its disassembly must be carried out only by authorized and
competent personnel.
• Before operang the device, check its correct assembly.
• Periodically, at least twice a year, the HEPA lter must be replaced. Filter
replacement must be carried out by authorized and competent personnel
equipped with appropriate personal protecve equipment (gloves) and
trained on how to handle and dispose the lter.
• If the device is to be decommissioned, we recommend to remove the power
cord. It is also recommended to remove the HEPA lter and dispose of it
according to the instrucons.
• The installaon must be carried out according to the manufacturer’s
instrucons, by authorized and competent personnel. Incorrect installaon
may cause damage to persons, animals or property for which the
manufacturer cannot be held responsible.
SURFACE DISINFECTION
The disinfecon of the internal surfaces of the car is carried out by means of
a UV-C lamp, which, when switched on, causes harmful emissions for people
inside the li car, even for short-term exposures. In case of direct exposure of
the skin to UV-C rays, an erythema may occur; some forms of eye diseases such
as photokeras, photoconjuncvis and cataract are due to the exposure of the
eyes. The ultraviolet light by the UV-C lamp should never be looked at directly
with the naked eye, without the use of a protecve screen.
USE
When the car is at one oor, with no passenger inside and no signal of occupied
car, the UV-C lamp switches on automacally acvang the surface disinfecon
funcon. When opening the door, before entering the car, check that the UV-C
lamp is actually switched o.
Protecve equipment against hazards due to exposure to UV-C radiaon:
• the system is equipped with a moon sensor detecng the movement of a
person inside the car and prevenng the UV-C lamp from switching on;
• the same sensor also detects body temperature at the same me to further
check for the presence of any person in the car;
• the opening of the door causes the immediate switching o of the UV-C lamp;
• the acvaon of any li movement control commands the UV-C lamp to
switch o;
• the opening of a landing door or the call from any oor operate the air
exchange system. The venlaon remains operaonal even when passengers
are in the car.
DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE)
This product complies with EU Direcve 2002/96/EC.
The crossed-out wheeled bin symbol indicates that waste electrical and electronic equipment should not be discarded together
with unseparated household waste, but must be collected separately. The operator is responsible for consigning the equipment
to appropriate collecon facilies at the end of its working life or they may face the penales provided for by current waste
management legislaon. The separate collecon for the delivery of the equipment to recycling, to treatment and environmentally
compable disposal helps avoid possible negave eects on the environment and health and promotes the reuse and / or recycling
of materials that make up the equipment. For more detailed informaon on the available waste collecon systems, contact your local
waste disposal service. Manufacturers and importers comply with their responsibilies for recycling, treatment and environmentally
compable disposal.
AIR FILTER DISPOSAL
Air lters, once exhausted, as well as their packaging, must be disposed of in accordance with the relevant applicable law. In any case, they must not be
thrown away or dispersed in the environment, but disposed of according to the CER idencaon code:
CER 150203 AIR FILTER - Exhausted, not recyclable.
CER 150101 OUTER PACKAGING - Paper box/cardboard box, recyclable.
CER 150102 INTERNAL PACKAGING - Plasc bag, recyclable.
Table of contents
Popular Industrial Equipment manuals by other brands

UnionSpecial
UnionSpecial BC200 ORIGINAL INSTRUCTIONS ENGINEERS, AND ILLUSTRATED PARTS MANUAL

SMC Networks
SMC Networks HF2A-ASG V Series Operation manual

SMC Networks
SMC Networks AFD20 D Series Operation manual

Ingersoll-Rand
Ingersoll-Rand C-Series installation manual

Somex
Somex MAX40COD Technical document

EASTMAN
EASTMAN Kodak X-Omat 180 LP Service manual