manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Immergas
  6. •
  7. Heater
  8. •
  9. Immergas AUDAX.DK4 User manual

Immergas AUDAX.DK4 User manual

Other manuals for AUDAX.DK4

2

This manual suits for next models

1

Other Immergas Heater manuals

Immergas JULIUS 11 ERP Operating instructions

Immergas

Immergas JULIUS 11 ERP Operating instructions

Popular Heater manuals by other brands

Porter-Cable PCXH80KT Operating instructions and owner's manual

Porter-Cable

Porter-Cable PCXH80KT Operating instructions and owner's manual

Dyna-Glo RA18LPDG user manual

Dyna-Glo

Dyna-Glo RA18LPDG user manual

Dimplex PLX050E instruction manual

Dimplex

Dimplex PLX050E instruction manual

EOS Herkules XL S120 installation instructions

EOS

EOS Herkules XL S120 installation instructions

Trebs Comfortheat 99209 manual

Trebs

Trebs Comfortheat 99209 manual

Biddle STYLE2 Series Installation operation & maintenance

Biddle

Biddle STYLE2 Series Installation operation & maintenance

Vermont Castings Non-Catalytic Convection Heater 2477CE Installation and operating manual

Vermont Castings

Vermont Castings Non-Catalytic Convection Heater 2477CE Installation and operating manual

Fagor RA-1505 Instructions for use

Fagor

Fagor RA-1505 Instructions for use

THERMAL FLOW Delta 175 Operating instructions manual

THERMAL FLOW

THERMAL FLOW Delta 175 Operating instructions manual

GET G2CH instructions

GET

GET G2CH instructions

ApenGroup PK Series User, installation, and maintenance manual

ApenGroup

ApenGroup PK Series User, installation, and maintenance manual

oventrop Regucor Series quick start guide

oventrop

oventrop Regucor Series quick start guide

Blaze King CLARITY CL2118.IPI.1 Operation & installation manual

Blaze King

Blaze King CLARITY CL2118.IPI.1 Operation & installation manual

ELMEKO ML 150 Installation and operating manual

ELMEKO

ELMEKO ML 150 Installation and operating manual

BN Thermic 830T instructions

BN Thermic

BN Thermic 830T instructions

KING K Series Installation, operation & maintenance instructions

KING

KING K Series Installation, operation & maintenance instructions

Empire Comfort Systems RH-50-5 Installation instructions and owner's manual

Empire Comfort Systems

Empire Comfort Systems RH-50-5 Installation instructions and owner's manual

Well Straler RC-16B user guide

Well Straler

Well Straler RC-16B user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

IT IE
Cod. 1.044225 - Rev. ST.004987/001
KIT RESISTENZA ANTIGELO AUDAX.DK4
COD. 3.030930
ANTIFREEZE HEATER KIT AUDAX.DK4
COD. 3.030930
AVVERTENZE GENERALI.
Tutti i prodotti sono protetti con idoneo imballaggio da trasporto.
Il materiale deve essere immagazzinato in ambienti asciutti ed al
riparo dalle intemperie.
Il presente foglio istruzioni contiene informazioni tecniche relative
all’installazione del kit. Per quanto concerne le altre tematiche corre-
late all’installazione del kit stesso (a titolo esemplicativo: sicurezza
sui luoghi di lavoro, salvaguardia dell’ambiente, prevenzioni degli
infortuni), è necessario rispettare i dettami della normativa vigente
ed i principi della buona tecnica.
L’installazione o il montaggio improprio dell’apparecchio e/o dei
componenti, accessori, kit e dispositivi potrebbe dare luogo a proble-
matiche non prevedibili a priori nei confronti di persone, animali,
cose. Leggere attentamente le istruzioni a corredo del prodotto per
una corretta installazione dello stesso.
L’installazione e la manutenzione devono essere eettuate in ottem-
peranza alle normative vigenti, secondo le istruzioni del costruttore e
da parte di personale abilitato nonché professionalmente qualicato,
intendendo per tale quello avente specica competenza tecnica nel
settore degli impianti, come previsto dalla Legge.
DESCRIZIONE KIT.
Il kit resistenza antigelo condensa, è stato realizzato per agevolare
il drenaggio della condensa generato durante il funzionamento
dell’unità esterna e non interferisce in alcun modo con le presta-
zioni della macchina. Il kit non è pensato per agevolare il funzio-
namento della macchina con temperature ambiente inferiori a 0°C.
Il kit è da utilizzare se l’unità esterna è installata in una zona in cui
ci può essere temperatura inferiore a -5°C e alta umidità relativa
per almeno tre giorni consecutivi.
La resistenza è composta da un cavo scaldante inserito all’interno
di un foglio di alluminio adesivo che conferisce essibilità e facilita
l’installazione.
La temperatura minima di funzionamento a cui può arrivare il
cavo scaldante è di -40°C.
Dati tecnici.
Resistenza 230V - 180W
Temperatura minima di funzionamento -40 °C
GENERAL WARNINGS.
All products are protected with suitable transport packaging.
e material must be stored in dry environments and protected
against weathering.
is instruction manual provides technical information for installing
the kit. As for the other issues related to kit installation (e.g. safety
in the work site, environment protection, injury prevention), it is
necessary to comply with the provisions specied in the regulations
in force and principles of good practice.
Improper installation or assembly of the appliance and/or compo-
nents, accessories, kit and devices can cause unexpected problems
to people, animals and objects. Read the instructions provided with
the product carefully to ensure a proper installation.
Installation and maintenance must be performed in compliance with
the regulations in force, according to the manufacturer's instructions
and by authorised professionally qualied sta, intending sta with
specic technical skills in the plant sector, as envisioned by the Law.
KIT DESCRIPTION.
e condensate antifreeze heater kit has been designed to facilitate
the drainage of condensate generated during the operation of the
outdoor unit and does not interfere in any way with the perfor-
mance of the machine. e kit is not designed to facilitate the
operation of the machine with ambient temperatures below 0°C.
e kit is to be used if the outdoor unit is installed in an area
where there can be temperature lower than -5 ° C and high relative
humidity for at least three consecutive days.
e heating element is made up of a heating cable inserted inside
an adhesive aluminum sheet which gives exibility and facilitates
installation.
e minimum operating temperature at which the heating cable
can reach is -40 ° C.
Technical Data.
Heating element 230V - 180W
Minimum operating temperature -40 °C
AVVERTENZE D’USO.
- Non deformare l’elemento;
- non alterare lo stato superciale mediante abrasione e/o sostanze
chimiche aggressive;
- non piegare i terminali elettrici di connessione;
- evitare il contatto dei cavi con spigoli taglienti;
-applicare al cavo di alimentazione un raggio minimo di curvatura
maggiore a 4 volte il diametro esterno del cavo;
- assicurare la direzione, intensità, contatto del uido/corpo di
scambio termico;
- la resistenza non è approvata ATEX, pertanto non può funzio-
nare in atmosfera esplosiva.
ISTRUZIONI PER L’INSTALLATORE.
Procedere nel seguente modo:
- Togliere alimentazione all’apparecchio.
- Smontare il pannello superiore e i pannelli frontali come mo-
strato in Fig. 1 e Fig. 2.
- Rimuovere la pellicola dall’adesivo della resistenza (Fig. 3 Rif.
1) ad eccezione della parte sotto la bandella “A” (strappando la
pellicola da rimuovere)
- Alzare la bandella “A” della resistenza (Fig. 3 Rif. 2) e applicare
la resistenza sul pianale come mostrato in Fig. 3 Rif. 3 adattan-
dola alla sagoma del pianale e premendola per far aderire bene
l’adesivo. Prima di applicare la resistenza se necessario pulire
accuratamente il pianale.
- Rimuovere la pellicola dall’adesivo della bandella “A” e appli-
carla al pianale facendola passare dietro il supporto ventola
(Fig. 3 Rif. 4).
- Incidere con un taglierino il passacavo presente sotto lo scam-
biatore e stendere il cavo secondo il percorso mostrato in Fig.
4 fascettandolo dove indicato.
- Collegare il cavo della resistenza al connettore X14A della scheda
controllo idronico.
- Riassemblare i pannelli frontali e superiore.
AVVERTENZE PER IL TECNICO.
La resistenza antigelo è stata collaudato e testato in fabbrica, non
occorre quindi testarlo o collaudarlo al momento dell’installazione.
È però molto importante accertarsi di avere eettuato il corretto
allacciamento elettrico del kit.
Terminate queste operazioni ridare tensione all’apparecchio.
N.B.: il kit antigelo una volta installato è sempre collegato e
funzionante. Nel caso si volesse testare lo stesso si può farlo dal
pannello della macchina Menu > Assistenza > Pompa di calore
> Manutenzione > Test kit riscaldatore.
WARNINGS FOR USE.
- Do not deform the element;
- do not alter the surface state by abrasion and / or aggressive
chemical substances;
- do not bend the electrical connection terminals;
- avoid contact of the cables with sharp edges;
- apply to the power supply cable a minimum radius of curvature
greater than 4 times the external diameter of the cable;
- ensure the direction, intensity, contact of the uid / heat exchan-
ge body;
- the resistance is not ATEX approved, therefore it cannot function
in an explosive atmosphere
INSTRUCTIONS FOR THE INSTALLER.
Proceed as follows:
- Remove power from the appliance.
- Remove the upper panel and the front panels as shown in Fig.
1 and Fig. 2.
- Remove the lm from the heating element adhesive (Fig. 3 Ref.
1) with the exception of the part under the band “A” (tearing
o the lm to be removed)
- Li the resistance band “A” (Fig. 3 Ref. 2 ) and apply the resi-
stance on the oor as shown in Fig. 3 Ref. 3 adapting it to the
shape of the oor and pressing it to make the adhesive adhere
well. Before applying the heating element, if necessary, carefully
clean the oor.
- Remove the lm from the adhesive of the strip “A” and apply it to
the platform by passing it behind the fan support (Fig. 3 Ref. 4).
- Cut the cable gland under the exchanger with a cutter and lay
the cable according to the path shown in Fig. 4 bundling it
where indicated.
- Connect the resistance cable to connector X14A of the hydronic
control board.
- Reassemble the front and top panels
WARNINGS FOR THE TECHNICIAN.
e antifreeze heater has been tested and tested in the factory,
therefore there is no need to test or test it at the time of installation.
It is however very important to make sure you have made the
correct electrical connection to the kit.
At the end of these operations, restore power to the appliance.
N.B.: once installed, the antifreeze kit is always connected and
functional. If you want to test the same, you can do it from the
panel of the machine Menu > Service > Heat pump > Mainte-
nance > Heating kit test.
1
3
2
54
7×
1×
1
3
2
54
7×
1×
2
3 2 1
1
2 1
1
3
4
2×
2×
2
2×
1
7×
2×
4×
1
3
2
2×
X14A
1×
1×
4×
2
3 2 1
1
2 1
1
2
3
4
2×
2×
2
2×
1
7×
2×
4×
1
3
2
2×
X14A
1×
1×
4×
A