Installation Instructions
+44(0) 203 051 1687 |[email protected]
INDO SiCURA - Installation Instructions
Carefully review this document before installing or maintaining the unit
Input: 240VAC, 50Hz
Weight: <4.8kg (all variants)
Windage: < 0.033m2
Design Mounting
Height:
Up to 8m
Mounting Options: PT 60mm - 76mm, SE
34mm – 60mm
Penetration
Requirement:
85mm PT, 100mm SE
Tools Required: Small at head
screwdriver
Torque wrench with 5mm
Hex bit
M4 Torx head (TX20) For
inclination adjustment if
required
Cleaning: Clean with a damp lint free
cloth. Do not use cleaning
agents. Any debris on the
top surface of the tting
should be washed out.
The light source contained in this
luminaire shall only be replaced
by the manufacturer or his service
agent or a similar qualied person.
This is a Class I luminaire and must
be earthed.
High voltage testing can cause
damage to LED ttings -
use appropriate installation
test method.
• Disconnect luminaire from the power supply
before performing any maintenance or any
kind of replacement
• Once re-connected, ensure suitable voltage
and frequency is supplied to the unit
• For health & safety, it is imperative that all
installation instructions are followed correctly
and with care
• INDO Lighting will not be held liable for any
accident, injury or damage caused
II-052 SiCURA - V2.0
Installation Recommendation:
The product is supplied with a default post
top and side entry inclination setting of 0°
If other inclination settings are required, we
recommend conguring the shim assembly rst
before mounting the unit. PT: pg 3 or SE: pg 6
Please keep this document for future reference or
bookmark the link below:
www.indolighting.com/installation
© 2019 INDO Lighting Ltd. All rights
reserved. Data subject to change
without notice
1
2
Post Top Installation
2 3
Stay must fall into the recess to lock the lid in the open position.
SHIM
SHIM
BLOCK
4
The product is supplied with a default post top and
side entry inclination setting of 0°. The observed
text on the shim and shim block are the settings.
Refer to the inclination sections below.
If no adjustment to the inclination is necessary,
go to the product mounting section.
1
Open unit with a 5mm Allen key / hex bit and undo the self-retaining bolts.
5 6
Remove and retain the long bolt. Remove the s
him block.
Flip the shim block over to observe the inclination
angle shown here for PT.
To adjust the post top inclination for +5° & +10°
7
Post Top 5° inclination: Flip shim block over to show 5° and secure back in place with the bolt.
Post Top 10° inclination: Remove shim block completely.
8
Mount Product on to column. Tighten Grub screws to 8-10 Nm.
Mount product on to column
3
11
4
9 10
Caution: Ensure the cable is routed through the centre
scoop and is not caught or crushed against the column.
Feed cable through cable gland and tighten.
Refer to the wiring diagram to suit the
installation requirements.
Wiring
12 13
To close unit, lift the lid slightly and ip the stay
so it drops into the recess. When closing the
luminaire take care to prevent any wires from
becoming trapped.
Incorrect stay position will cause damage to the
product and will compromise the IP rating.
Close unit
14
Close unit with a torque wrench to 7 Nm.
CRUSH
RISK
1 2
Remove grub screws.
Change door to the horizontal position.
Fit grub screws. Mount product on to bracket.
Tighten grub screws to 8-10 Nm.
3
Open unit with a 5mm allen key
/ hex bit and undo the self-
retaining bolts.
Side Entry Installation
4
Stay should fall into the recess to lock the lid in the open position.
SHIM
SHIM
BLOCK
The product is supplied with a default post top and
side entry inclination setting of 0°. The observed
text on the shim and shim block are the settings.
To adjust this, refer to the inclination settings
overleaf. If no adjustment to the inclination is
necessary, go to the mounting section on page 7.
5
5
6
To adjust the side entry inclination for -5° & -10°
6 7
Remove and retain the short bolt.
Remove the shim.
Flip the shim block over to observe the inclination
angle - shown here for SE.
8
Side Entry -5° inclination: Flip shim block over to
show SE-5° and secure back in place with the bolt.
Do not over tighten bolt to allow the shim to
self-locate on to the bracket.
Side Entry -10° inclination: Remove shim
completely.
To adjust the side entry inclination for +5° & +10°
9 10
Remove and retain both the long and short bolt.
Remove the shim and shim block.
Flip the bottom shim over as required for +5°
& +10°. Combine Shim & Shim Block and
nest together.
11 12
For SE mounting, ignore PT text.
Observe the + inclination angle
shown in the window.
Fit the shim assembly back into place with the teeth towards
the back of the unit. Secure the combined shim and shim block
assembly in place with the long bolt. Do not over tighten bolt to
allow the shim to self-locate on to the bracket.
13
Mount Product on to bracket.
Tighten Grub screws to 8-10 Nm.
Mount product on to bracket
16
15
Feed cable through cable gland and tighten. Refer to the wiring diagram to suit the
installation requirements.
Wiring
17 18
To close unit, lift the lid slightly
ip the stay so it drops into
the recess. When closing the
luminaire take care to prevent any
wires from becoming trapped.
Incorrect stay position will cause
damage to the product and will
compromise the IP rating.
Close unit
19
Close unit with a torque wrench to
7 Nm.
14
7

Popular Outdoor Light manuals by other brands

Gainsborough L120 instructions

Gainsborough

Gainsborough L120 instructions

Everglow HK Series Installation and Maintenance

Everglow

Everglow HK Series Installation and Maintenance

Malatech HELIODOR 5 BLACK user manual

Malatech

Malatech HELIODOR 5 BLACK user manual

LightPro Oberon Lo 190P user manual

LightPro

LightPro Oberon Lo 190P user manual

Luxision Typ FARA Vela Assembly and operating instructions

Luxision

Luxision Typ FARA Vela Assembly and operating instructions

LIGMAN LD-50022 instruction manual

LIGMAN

LIGMAN LD-50022 instruction manual

MULTILINE MURRO Mounting instruction

MULTILINE

MULTILINE MURRO Mounting instruction

Inspire Lakko G18082P Assembly, Use, Maintenance Manual

Inspire

Inspire Lakko G18082P Assembly, Use, Maintenance Manual

Outwell COXA 1.5 instruction manual

Outwell

Outwell COXA 1.5 instruction manual

JONATHAN Y JYL2069A quick start guide

JONATHAN Y

JONATHAN Y JYL2069A quick start guide

LIGMAN SE-90022-SU installation manual

LIGMAN

LIGMAN SE-90022-SU installation manual

PLG SIRIO INOX user manual

PLG

PLG SIRIO INOX user manual

HORNER ETG-A100A installation guide

HORNER

HORNER ETG-A100A installation guide

NOVOLUX BARRI 574C Installation

NOVOLUX

NOVOLUX BARRI 574C Installation

LIGMAN LIGHT LINEAR PT 3 installation manual

LIGMAN

LIGMAN LIGHT LINEAR PT 3 installation manual

Nemo SKILLED installation instructions

Nemo

Nemo SKILLED installation instructions

Anslut 001947 operating instructions

Anslut

Anslut 001947 operating instructions

Vaxcel T0517 Assembly and installation instructions

Vaxcel

Vaxcel T0517 Assembly and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.