Inel YYGL35P-10/17 User manual

P. I. E. INEL Sp. z o. o., ul. Mostowa 1, 80-778 Gdańsk, [email protected] www.inel.gda.pl
Operating instructions
Overload detection motor
YYGL35P-10/17
YYGL45P-20/15
In order to ensure the correct operation of the motor, use
blocking hangers and stoppers in the lower slat. The
window must be fitted with a sill. The length of the curtain
must be adjusted to the length of the guides.
1. SAFETY GUIDELINES
1.1 Basic guidelines
The overload detection motor is delivered in a condition allowing
for safe installation and operation, provided that all guidelines
herein as well as relevant safety and accident prevention
regulations are observed. Only qualified and licenced personnel
is allowed to install and repair electrical devices. It is prohibited
to make any changes or modifications to the drive. Warranty
repairs may be conducted only by the manufacturer. Use only
original spare parts and accessories during post-warranty
repairs. Operational safety of the drive can only be ensured if it
is used for its intended purpose. Do not exceed limit values
given
in technical information.
1.2 Additional safety regulations
Observe relevant safety and accident prevention regulations
when installing, commissioning and maintaining the drive. The
following must be given special consideration:
1. Fire safety regulations.
2. Accident prevention regulations.
1.3 General notes on risks and safety measures
These notes are general guidelines for the use of INEL devices
in combination with other devices. These guidelines must be
strictly observed when installing and operating the devices.
Warning - against possible damage to the drive,
roller blind, roller blind cassette, elevation etc. if no
relevant safety measures are taken:
• Check if all screw connections are secure before
installing the drive and setting limit switches
Danger - means that there is a threat to life and
limb of the user if no relevant safety measures are
taken:
Check the compatibility of the permissible
voltage of the device with the local power supply before
connecting.
Observe applicable safety and accident prevention
regulations.
Use an isolation switch allowing for safe power supply
disconnection (e.g. fuse cut-off switch) installed in such a
way that all connections can easily be cut out.
Inspect wires and cables regularly for damaged insulation
and conductor continuity.
If any damage is identified, cut off power immediately and
replace the damaged wiring.
1.4 Warning
Do not allow children to play with control devices.
Keep the remote control out of reach of children.
Observe the moving roller blind and keep people away until
it fully opens or closes.
The users of the roller blind must be instructed in its
operation and existing risks related to its usage. Persons
are deemed to have been trained if the employer,
administrator or owner allowed them to use the roller blind
and instructed them in its operation.
It is not permitted to dispose of waste equipment
together with other waste. Dispose only in specially
designated areas. The household plays a key role in
the recycling of waste equipment. By correct sorting of waste,
including waste equipment and batteries, household members
ensure that the equipment is not disposed together with
household waste, but in specially designated areas, and thus
may be used again after recycling.
2. INSTALLATION INSTRUCTIONS
2.1 Safety regulations
Only persons with appropriate authorisation may install the
drive.
The weight of the roller blind may not exceed the maximum
load of the drive specified in the selection table (see the
end of the instructions)
Routing the cable properly (loop aimed downwards) will
protect the drive against any water damage.
Do not drill holes in motor housing.
Protect the motor against contact with any liquids.
Avoid crushing and impacting the motor, protect the motor
against shock.
Do not connect more than one on/off switch to a single
motor.
Figure 1
2.2 Installing the motor
Fix the mounting bracket (A) to the side of the roller blind
cassette, connect the adapter (D) to the thrust ring of the
motor (C).
Place an appropriate driver provided with the motor (E)
on the motor axis, secure it with a pin (F), and slide the
entire motor to the roller tube (G).
WARNING: The motor is fitted with an internal thermal cut-out
which allows the roller blind to work continuously for ca. 4 min.
After this time the temperature inside the motor will exceed the
permissible value, which will cause power cut-out. Subsequent
vertical movement of the roller blind will only be possible after
the motor cools down (it can take up to twenty minutes). Using
this cut-out greatly increases the life of the drive.
Figure 2
NO
YES

P. I. E. INEL Sp. z o. o., ul. Mostowa 1, 80-778 Gdańsk, [email protected]
www.inel.gda.pl
2.3 Electrical connections
DISCONNECT POWER SUPPLY BEFORE MAKING
ANY CONNECTIONS!
Improper roller blind installation will cause the
motor to stop unexpectedly.
3. STARTUP
After delivery from the manufacturer the motor is factory
set. The motor will adjust to the roller blind used after
making 3 stops in the upper and lower limit position. After
that the motor will be ready for use.
The motor detects low rpm caused by overload, and locks
the direction it was moving before being stopped. In order
to unlock the direction, move in the opposite direction for at
least 1 second.
The service cable is fitted with two buttons and one switch:
(2-position, bistable) – applies voltage to the
'up' direction only.
(monostable) – allows for applying voltage to
the 'up' direction.
(monostable) – allows for applying voltage to
the 'down' direction.
Previously used service cable
The monostable "Program" button allows for
applying voltage to the 'up' direction.
The tristable switch allows for applying voltage
to the 'up' and 'down' directions.
Applying voltage to both directions at the same
time is possible after pressing both the
"Program" and "Down" switch.
5. RETURN TO FACTORY MODE
You can return to the factory mode at any time - however, you
will need to perform the adjustment procedure described in
section 3 again.
To enter factory mode you can use a service cable. Applying
voltage to two directions at the same time for at least 3
seconds will reset to factory mode, which will be confirmed by
a short up-down movement of the roller blind.
4. SERVICE CABLE
Before drive startup/programming check the
condition of the curtain, guides and roller blind
cassette and whether there is a sill mounted in the
window!
The roller blind cassette and guides should be free from
any contaminants and ensure unrestricted curtain
movement throughout the entire length. If the guides are
contaminated with building materials or are too tight,
they can cause damage to the drive and the roller blind,
which is not covered by the warranty.
N - neutral
PE - protective
L - phase
black
yellow-green
grey
– not used
blue
brown
Figure 3

P. I. E. INEL Sp. z o. o., ul. Mostowa 1, 80-778 Gdańsk, [email protected]
www.inel.gda.pl
6. TROUBLESHOOTING
Problem: The motor does not react to commands
Cause: Thermal cut-out was activated
Solution: Wait for 10-20 minutes
Problem: Curtain fins do not close fully
Cause: The curtain is blocked in the guides
Solution: Check the roller blind guides and curtain slats
Problem: Curtain fins do not close fully
Cause: Roller blind too long
Solution: Shorten the roller blind curtain
Problem: The motor stops on its own
Cause: The curtain is blocked in the guides
Solution: Check the roller blind guides and curtain slats
Problem: The motor does not detect obstacles when
moving down.
Cause: Wrong hangers used.
Solution: Install blocking hangers.
WARNING! Pauses between individual presses of the blind
switch buttons should be at least 1 second long!
7. MOTOR SELECTION TABLE
TORQUE
ROLLER BLIND LENGTH
This manual suits for next models
1
Table of contents
Other Inel Engine manuals
Popular Engine manuals by other brands

Sea-doo
Sea-doo Rotax 1503 4-Tec 2005 Engine shop manual

Harmonic Drive
Harmonic Drive HFUS-2SO Assembly and service manual

In-situ
In-situ Aqua TROLL 600 Operator's manual

Vanguard
Vanguard 54E000 Operator's manual

Oriental motor
Oriental motor BMU Series quick start guide

Tecnoautomazione
Tecnoautomazione TM4 Series manual