1COMMAND LINE INTERFACE
1.1.1 Purpose
This specification defines the serial command line streams for controlling
an InFocus projector through the RS232 connector to the projector.
These commands are intended to provide a simple set of controls to the
projector through what InFocus calls the Command Line Interface (CLI).
The CLI is designed for use by what the industry commonly calls
boardroom controllers. The CLI will accept commands via RS232 to
control the necessary features used by most boardroom controllers. This
CLI language uses a simple human readable protocol to help facilitate the
installers’ time necessary to setup or diagnose a problem with boardroom
control installations. However, the CLI is not a guaranteed delivery
system.
1.1.2 Message Format
As commonly used in math notation, everything is evaluated in the
parenthesis first, as the parentheses are designed to group things
together. This same parenthesis nomenclature is used to group a
command and its data together (nested parenthesis are not supported).
All commands are three alpha characters followed by the request. The
request can be a “?” symbol that signifies a read request, or a numerical
number represented by 1 to 4 ASCII digits, that signifies a write request.
Not all commands support reading and writing. The command table
indicates the commands and requests that are supported. There are also
support commands available on non CLI format.
1.1.3 Write Commands
Write commands have the following format:
(AAA####) where,
( - starts the CLI command
AAA - denotes the CLI function
#### - denotes the value to be written (leading zeros are
not necessary)
) - ends the CLI command
Some functions have ranges for settings while others are Boolean.
Settings with ranges range from zero to a maximum number. If a
number greater than the maximum is received, it is automatically limited
to the maximum number for that function. IT IS SUGGESTED THAT EACH