Introduction
This application note is a guide for users to operate iBS01 beacons. The quick verification is using
Nordic’s Master Control Panel Android APP. Please download this APP with the link below:
https://play.google.com/store/apps/details?id=no.nordicsemi.android.mcp.
Operation
There is no battery shipped with the tag. User has to put 2x CR2032 coin batteries inside the tag. The figure on the
right is an instruction for inserting the battery.
Users can also power the tag by a micro-USB cable from a standard USB host port(like the USB port in a PC) or normal
smartphone charger.
There is a power switch like in
the figure below. Switching
on/off depends on the power
source. After power on, it starts
and continuously advertises the
beacon message through BLE.
Switch
Position
USB
Power
CR2032
Battery
Right
On
Off
Left
Off
On
Caution: risk of explosion if the battery is replaced by an incorrect type. Dispose of used batteries according to the instructions
iBS01H sensor position
The iBS01H is using a hall sensor to detect if a magnet is in range or not. Depending on the
strength of the magnet, the range is around 0.5cm~1.5cm. The sensor position is marked on
the enclosure.
INGICS TECHNOLOGY CO., LTD. • [email protected] • WWW.INGICS.COM
1

INGICS TECHNOLOGY
Quick Start
When powered on iBS01 Tag starts to advertise immediately. User can use BLE scan app to scan iBS01 Tag to get
payload to see its working.Detail procedure as following:
1. Power on iBS01 with Battery or
USB without pressing the button.
2. Scan to find iBS01 Tag
3. Tag Info is in payload, detail information
please check format document
Notes when using Master Control Panel APP
●When scanning the BLE device when using the Master Control Panel, you can see current nearby BLE devices and
the cached BLE device that do not currently exist. To tell the difference, check the RSSI value. If the RSSI is not in
solid color then the device does not currently exist. Or you can use “refresh” in the settings menu( at the top right
corner) to clear the cached information.
Configuration
There are several parameters you may want to configure. Basic procedure is as below.
1. Press and hold the config button on top of the iBS01(right figure) and power on the iBS01.
After power on, release the button. iBS01 will enter the configure mode.
2. Open iBS01 Utility and push scan device
3. Connect and change the parameters.
INGICS TECHNOLOGY CO., LTD. • [email protected] • WWW.INGICS.COM
2

INGICS TECHNOLOGY
4. Disconnect and the iBS01 will go into normal mode.
Waste Electrical and Electronic Equipment Recycling
Our product is compliant with the WEEE directive for re-use/recovery/recycling. This cross-out
wheeled-bin symbol is a reminder that this product should not be treated as household waste. Instead
hand it over to the appropriate collection point for the recycling of electrical and electronic equipment in
accordance with local environmental regulations for waste disposal.
Since our product is not sold directly to the end user and generally it is a part of our customer’s solution,
our customer is recognized as a professional seller. Our customer has the responsibility to comply with
the requirement of the directive too. To help our customers, when necessary, we will provide a WEEE
compliant assessment report for registering and communicating with the local authorities and recycling
agency.
INGICS TECHNOLOGY CO., LTD. • [email protected] • WWW.INGICS.COM
3

INGICS TECHNOLOGY
Certification
Japan MIC Regulatory
201-160404
FCC Regulatory
2AH2IIBS01
NCC Regulatory
CCAJ16LP4280T1
Statement
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one of the following measures: . Reorient or relocate the receiving antenna. . Increase the separation
between the equipment and receiver. . Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected. . Consult the dealer or an experienced radio/TV technician for help.
FCC Caution:To assure continued compliance, any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface
cables when connecting to computer or peripheral devices).
FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters
between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used
for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept any interference received, including interference that may
cause undesired operation.
NCC 警語
第十二條
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者
均不得擅自變更頻率、加大功率或變更原設計之特性及功能。
第十四條
低功率射頻電機之使用不得影響飛航安全及干擾合法通信; 經發現有
干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。
前項合法通信,指依電信法規定作業之無線電通信。
低功率射頻電機須忍受合法通信或工業、 科學及醫療用電波輻射性電
機設備之干擾
INGICS TECHNOLOGY CO., LTD. • [email protected] • WWW.INGICS.COM
4

INGICS TECHNOLOGY
CE Regulatory
iBS01 series has been tested and complies with the essential requirements of the DIRECTIVE
2014/53/EU. Below is the copy of the CE Conformity of Declaration.
INGICS TECHNOLOGY CO., LTD. • [email protected] • WWW.INGICS.COM
5

INGICS TECHNOLOGY
Revision History
DATE
REVISION
CHANGES
May 25, 2016
1
Initial release
Feb 1, 2017
2
Add configuration section
Jul 7, 2017
2a
To meet EU RED - DIRECTIVE 2014/53/EU
1. Add battery warning on page 1
2. Add DOC on last page
June 2, 2021
2b
1. Add Waste Electrical and Electronic Equipment Recycling
section for appropriate recycling the equipment
2. Rearrange page
3. Add Certification section
INGICS TECHNOLOGY CO., LTD. • [email protected] • WWW.INGICS.COM
6
Table of contents
Other Ingics Security System manuals
Popular Security System manuals by other brands

Clifford
Clifford GP500 user manual

Digital Monitoring Products
Digital Monitoring Products XT INTERNATIONAL Series user guide

GARDINER TECHNOLOGY
GARDINER TECHNOLOGY Gardtec 500 series user manual

Eagle Alarm Verification Products
Eagle Alarm Verification Products 2244 installation instructions

DSC
DSC Power632 instruction manual

Starline
Starline S9 quick start guide